  • Severity pendingNHTSA·24V083000·2024-02-08

    Volvo Bus 9700 Recalled for Potential Steering Link Rod Detachment

    Volvo Bus is recalling 2024 9700 vehicles because a loose nut may allow the steering link rod to detach, risking loss of steering control.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V668000·2023-10-03

    Volvo Bus Recalls 2023 9700 Models Due to Power Cable Fire Risk

    Volvo Bus is recalling 2023 9700 vehicles because power cable fasteners may not be tightened securely, which can cause overheating and increase the risk of a fire.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V917000·2022-12-12

    Volvo Bus 9700 Recalled for GPS Installation Defect

    Volvo Bus is recalling 2022 9700 buses because incorrectly installed GPS devices may cause accelerator sensor malfunction and loss of drive power.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V724000·2019-10-09

    Volvo Bus 9700 Recalled for Insufficient Seat Belt Anchorages

    Volvo Bus is recalling 2018-2020 9700 models because passenger seat belt attachments may not anchor properly, increasing injury risk in crashes.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V173000·2017-03-14

    Volvo Bus Recalls 2016-2017 9700 Models for Engine Stall Risk

    Volvo Bus is recalling 2016-2017 9700 transit buses because a ground cable may be improperly installed, causing the engine to stall unexpectedly.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V836000·2016-11-18

    Volvo Bus Recalls 9700 Models Due to Engine Stall Risk

    Volvo Bus is recalling 2008-2017 9700 buses because an undersized power feed relay may fail, causing the engine to stall and increasing crash risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V604000·2015-09-28

    Volvo Bus 9700 Recall: Exhaust Clamp Failure May Cause Fire

    Volvo is recalling 2009-2013 9700 buses because a failing exhaust clamp allows hot gas to contact engine materials, increasing fire risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V171000·2013-05-01

    Volvo Bus 9700 Recall: Software Defect May Fix Throttle Speed

    Volvo Bus is recalling 2009-2013 9700 coaches because a software defect may fix the throttle at 1750 RPMs, preventing drivers from controlling speed.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V450000·2012-09-13

    Prevost Recalls 2009-2013 Volvo Bus 9700 Coaches for Fire Risk

    Prevost is recalling 2009-2013 Volvo Bus 9700 coaches because a cracked hydraulic pipe may spray oil on hot engine parts, causing a fire.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V313000·2012-07-05

    Volvo Bus 9700 Recall for Improperly Secured Passenger Seat Tracks

    Prevost Cars is recalling 2009-2011 Volvo Bus 9700 models because passenger seat wall mounting tracks may not be properly secured, increasing injury risk in a crash.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V295000·2012-06-26

    Prevost Recalls 2009-2012 Volvo 9700 Motor Coaches Due to Software Error

    Prevost is recalling 2009-2012 Volvo 9700 motor coaches because a software error may cause the vehicle to stop suddenly if the wheelchair lift door is not fully closed.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V600000·2026-09-18

    Volvo Bus 9700 Recall for Missing Emergency Exit Instructions

    Volvo Bus is recalling 2009-2025 9700 buses because the emergency exit label on the entrance door is missing operating instructions, which may delay evacuation.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V893000·2024-11-26

    Volvo Bus Recalls 2025 9700 Models for Emergency Exit Label Defect

    Volvo Bus is recalling 2025 9700 buses because emergency exit labels may detach, potentially delaying evacuation and increasing injury risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V524000·2024-07-09

    Volvo Bus 9700 Recall for Steering Gear Link Rod Nut Tightening

    Volvo Bus is recalling 2024 9700 vehicles because improperly tightened nuts on the steering gear link rod may loosen, potentially causing loss of steering control.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V222000·2022-04-06

    Volvo Bus Recalls 2020 9700 DOT Vehicles Due to Fire Risk

    Volvo Bus is recalling 48 2020 9700 DOT vehicles because a seizing alternator bearing can overheat and cause a fire. Owners will receive replacement belts free of charge.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V717000·2021-09-15

    Volvo Bus 9700 Recalled for Non-Compliant Headlight Output

    Volvo Bus is recalling 2008-2021 9700 vehicles because headlights may be too bright or dim, failing federal safety standards and increasing crash risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V803000·2020-12-21

    Volvo Bus Recalls 2015-2020 9700 Models for Transmission Hub Failure

    Volvo Bus is recalling 2015-2020 9700 buses because a transmission hub may fail, potentially disabling the vehicle and forcing passengers to transfer on the roadside.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V091000·2014-03-04

    Volvo Bus 9700 Recall: Sliding Seat Locking Defect

    Volvo is recalling 2009-2014 9700 coaches with wheelchair lifts because sliding seats may not latch correctly, increasing injury risk in a crash.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V591000·2013-11-22

    Volvo Bus 9700 Recalled for Insufficient Emergency Exit Windows

    Volvo is recalling 10 wheelchair-accessible 2009-2010 9700 motor coaches that lack required emergency exit windows, posing an injury risk during emergencies.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V474000·2013-09-26

    Volvo Bus Recalls 2013 9700 Coaches for Parking Brake Defect

    Volvo Bus is recalling 2013 9700 coach buses because a manufacturing error may cause the parking brake to fail to fully apply, increasing crash risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V539000·2012-11-15

    Volvo Bus 9700 Recalled for Wheelchair Lift Safety Pin Defects

    Prevost is recalling 44 Volvo Bus 9700 coaches because missing or inoperable wheelchair lift safety pins may prevent safe stowing, increasing injury risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V205000·2012-05-08

    Volvo Bus 9700 Recalled for Insufficient Emergency Exit Windows

    Prevost is recalling 2009-2013 Volvo 9700 motor coaches because some have too few emergency exit windows to meet federal safety standards.