The Recall Desk

Vehicle

Volvo Bus 9700 · 2013

12 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–12 of 12

  • Severity pendingNHTSA·16V836000·2016-11-18

    Volvo Bus Recalls 9700 Models Due to Engine Stall Risk

    Volvo Bus is recalling 2008-2017 9700 buses because an undersized power feed relay may fail, causing the engine to stall and increasing crash risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V604000·2015-09-28

    Volvo Bus 9700 Recall: Exhaust Clamp Failure May Cause Fire

    Volvo is recalling 2009-2013 9700 buses because a failing exhaust clamp allows hot gas to contact engine materials, increasing fire risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V171000·2013-05-01

    Volvo Bus 9700 Recall: Software Defect May Fix Throttle Speed

    Volvo Bus is recalling 2009-2013 9700 coaches because a software defect may fix the throttle at 1750 RPMs, preventing drivers from controlling speed.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V450000·2012-09-13

    Prevost Recalls 2009-2013 Volvo Bus 9700 Coaches for Fire Risk

    Prevost is recalling 2009-2013 Volvo Bus 9700 coaches because a cracked hydraulic pipe may spray oil on hot engine parts, causing a fire.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V600000·2026-09-18

    Volvo Bus 9700 Recall for Missing Emergency Exit Instructions

    Volvo Bus is recalling 2009-2025 9700 buses because the emergency exit label on the entrance door is missing operating instructions, which may delay evacuation.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V717000·2021-09-15

    Volvo Bus 9700 Recalled for Non-Compliant Headlight Output

    Volvo Bus is recalling 2008-2021 9700 vehicles because headlights may be too bright or dim, failing federal safety standards and increasing crash risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V091000·2014-03-04

    Volvo Bus 9700 Recall: Sliding Seat Locking Defect

    Volvo is recalling 2009-2014 9700 coaches with wheelchair lifts because sliding seats may not latch correctly, increasing injury risk in a crash.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V474000·2013-09-26

    Volvo Bus Recalls 2013 9700 Coaches for Parking Brake Defect

    Volvo Bus is recalling 2013 9700 coach buses because a manufacturing error may cause the parking brake to fail to fully apply, increasing crash risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V539000·2012-11-15

    Volvo Bus 9700 Recalled for Wheelchair Lift Safety Pin Defects

    Prevost is recalling 44 Volvo Bus 9700 coaches because missing or inoperable wheelchair lift safety pins may prevent safe stowing, increasing injury risk.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V205000·2012-05-08

    Volvo Bus 9700 Recalled for Insufficient Emergency Exit Windows

    Prevost is recalling 2009-2013 Volvo 9700 motor coaches because some have too few emergency exit windows to meet federal safety standards.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all Volvo Bus models