39 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–39 of 39

  • Severity pendingNHTSA·26V362000·2026-06-04

    Chrysler Recalls 2020-2022 Pacifica Plug-In Hybrids for Fire Risk

    Chrysler is recalling 2020-2022 Pacifica Plug-In Hybrid Electric vehicles because the battery pack may cause a fire, even when parked.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V876000·2025-12-17

    Wheelchair restraint retractors in converted vans may fail to lock

    Rollx Vans is recalling certain converted vehicles equipped with QRT-Deluxe and QRT-Max wheelchair restraints, because the retractors may not lock and the wheelchair may not be properly secured.

    Product
    DODGE — DODGE, RAM, CHRYSLER GRAND CARAVAN, PROMASTER, PACIFICA, ODYSSEY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V238000·2024-03-28

    Chrysler minivan windshields may not be properly bonded to the vehicle

    Chrysler is recalling certain 2024 Pacifica and Voyager vehicles whose windshields may not have been properly bonded, allowing them to detach during a crash. This fails FMVSS 212.

    Product
    CHRYSLER — CHRYSLER VOYAGER, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V199000·2024-03-14

    2023-2024 Jeep Wrangler and Ram Vehicles Steering Module Airbag Defect

    Chrysler is recalling 2023-2024 Jeep Wrangler, Ram, Pacifica, and other vehicles because a faulty steering column control module may prevent driver airbag deployment in a crash. Dealers will replace the module free of charge.

    Product
    RAM — RAM, JEEP, CHRYSLER 1500, 2500, 5500, WAGONEER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V500000·2023-07-20

    2023 Chrysler Pacifica Plug-In Hybrid Fuel Line Defect Recall

    Certain 2023 Chrysler Pacifica Plug-In Hybrid Electric vehicles may have deformed fuel lines that could leak, increasing fire risk. Dealers will replace the fuel lines free of charge.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V348000·2019-05-09

    Chrysler Recalls 2017-2019 Pacifica Vehicles Due to Battery Ground Defect

    Chrysler is recalling 2017-2019 Pacifica vehicles with stop/start systems because a loose battery ground connection may cause power steering loss or stalling, increasing crash risk.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V143000·2019-02-28

    Chrysler Recalls 2018 Pacifica Models Due to Control Arm Separation Risk

    Chrysler is recalling 47,771 2018 Pacifica and Pacifica Plug-In Hybrid vehicles because the right front lower control arm may separate, increasing crash risk.

    Product
    CHRYSLER — CHRYSLER PACIFICA PLUG-IN HYBRID, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V492000·2018-07-26

    Chrysler Recalls 2018 Pacifica and 2019 Jeep Cherokee for Transmission Weld Defect

    Chrysler is recalling 2018 Chrysler Pacifica non-hybrid and 2019 Jeep Cherokee vehicles because a transmission component may not be welded properly, which could cause the vehicle to stop moving.

    Product
    JEEP — JEEP, CHRYSLER CHEROKEE, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V493000·2018-07-26

    Chrysler Recalls 2018 Pacifica Vehicles Due to Axle Assembly Defect

    Chrysler is recalling 2018 Pacifica vehicles because front axle halfshafts may be incorrectly assembled. This defect could cause loss of drive or movement in Park, increasing crash risk.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V332000·2018-05-17

    Chrysler Recalls Vehicles for Cruise Control Disengagement Defect

    Chrysler is recalling over 4.8 million vehicles because a wiring short may prevent the cruise control system from disengaging, increasing crash risk.

    Product
    JEEP — JEEP, RAM, CHRYSLER WRANGLER, CHEROKEE, GRAND CHEROKEE, 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V482000·2017-07-28

    Chrysler Pacifica Recall: Rear Pinion Bracket Cracking Risk

    Vantage Mobility International is recalling 2017 Chrysler Pacifica lowered floor vehicles because rear pinion brackets may crack, causing wheel wobble and potential loss of control.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V342000·2017-05-25

    Vantage Mobility Recalls 2017 Chrysler Pacifica Vans Due to Brake Line Defect

    Vantage Mobility is recalling 2017 Chrysler Pacifica vans modified for wheelchair accessibility because crossed rear brake lines may render the anti-lock brake system ineffective.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V531000·2026-08-13

    Chrysler Recalls 2026-2027 Vehicles for Rearview Camera Display Failure

    Chrysler is recalling 2026-2027 Jeep, Ram, Chrysler, and Dodge vehicles because the rearview camera image may fail to display when reversing, increasing crash risk.

    Product
    RAM — RAM, JEEP, DODGE PROMASTER, 2500, 1500, WRANGLER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V358000·2026-06-02

    Chrysler Recalls Pacifica and Voyager Models Due to Air Bag Defect

    Chrysler is recalling 2023-2026 Pacifica and Voyager vehicles because a spring may prevent air bags from deploying, increasing injury risk.

    Product
    CHRYSLER — CHRYSLER PACIFICA, VOYAGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V327000·2026-05-21

    Chrysler and Ram rearview cameras may fail to display an image

    Chrysler is recalling certain Pacifica, Ram 1500, Ram 2500 and Jeep Wrangler vehicles because contamination or improper programming may stop the rearview camera image displaying.

    Product
    RAM — RAM, JEEP, CHRYSLER 1500, 2500, WRANGLER, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V296000·2026-05-11

    2024 Chrysler Pacifica wheelchair restraints may not lock properly

    Braun Corporation is recalling certain 2023–2026 Chrysler Pacifica vehicles because wheelchair retractors may not lock, preventing proper securement. An unsecured wheelchair can move during transit and increase injury risk.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V189000·2026-03-26

    Chrysler Voyager and Pacifica side curtain airbags recall

    Chrysler is recalling certain 2022–2026 Voyager and Pacifica vehicles because the right and left side curtain airbags may have insufficient pressure retention due to improperly sealed seams, increasing the risk of ejection and injury during a crash.

    Product
    CHRYSLER — CHRYSLER VOYAGER, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V877000·2025-12-17

    Chrysler Pacifica wheelchair restraints may not lock securely

    Vantage Mobility is recalling 2021–2025 Chrysler Pacifica vehicles equipped with QRT-Deluxe and QRT-Max wheelchair restraints because the retractors may fail to lock, allowing wheelchairs to move unsecured during transit.

    Product
    TOYOTA — TOYOTA, HONDA, CHRYSLER SIENNA HYBRID, ODYSSEY, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V573000·2025-09-04

    2025 Chrysler Pacifica side curtain air bags recalled for inadequate pressure retention

    Chrysler is recalling certain 2025 Pacifica and Voyager vehicles due to defective side curtain air bags. The air bags may have insufficient pressure retention from improperly sealed seams, increasing the risk of ejection during a crash.

    Product
    CHRYSLER — CHRYSLER PACIFICA, VOYAGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V471000·2025-07-17

    Chrysler Pacifica built with wrong radio may not show rearview image

    Chrysler is recalling certain 2024-2025 Pacifica vehicles that were built with an incorrect radio, which can prevent the rearview camera image displaying. All affected vehicles have been repaired.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V302000·2025-05-08

    Chrysler Pacifica curtain airbag seams may not retain pressure

    Chrysler is recalling certain 2022-2025 Pacifica and Voyager vehicles because improperly sealed seams may leave the side curtain airbags with insufficient pressure retention.

    Product
    CHRYSLER — CHRYSLER PACIFICA, VOYAGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V888000·2024-11-25

    Braun converted Chrysler minivans may be missing the seat limiter

    Braun Corporation is recalling certain 2024 Chrysler Pacifica and Voyager vehicles because the seat limiter may not have been installed, allowing the seat to move too far forward.

    Product
    CHRYSLER — CHRYSLER PACIFICA, VOYAGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V793000·2024-10-24

    Chrysler Pacifica side curtain airbag connectors may be improperly secured

    Chrysler is recalling certain 2020-2023 Pacifica and Voyager vehicles because an improperly secured side curtain airbag connector may prevent the airbags from deploying.

    Product
    CHRYSLER — CHRYSLER VOYAGER, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V436000·2024-06-13

    Radio software may disable rearview camera in multiple Chrysler vehicle models

    Certain 2021-2023 Chrysler, Jeep, Ram, and Dodge vehicles have defective radio software that may prevent the rearview camera from displaying, reducing driver visibility when backing up.

    Product
    JEEP — JEEP, CHRYSLER, RAM GRAND CHEROKEE, VOYAGER, GRAND WAGONEER, COMPASS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V240000·2024-03-28

    Chrysler minivan traction control does not work with cruise control active

    Chrysler is recalling certain 2024 Pacifica and Voyager vehicles because the traction control system does not function while cruise control is activated. A free software update is the remedy.

    Product
    CHRYSLER — CHRYSLER VOYAGER, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V753000·2023-11-09

    2023 Chrysler Pacifica recall: battery isolator fire hazard

    Chrysler is recalling 32 2023 Pacifica plug-in hybrid vehicles due to an electrical short from an incorrectly installed battery isolator post that may cause fire while parked or driving.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V010000·2023-01-17

    Chrysler Pacifica Electrical Short Circuit May Cause Engine Shutdown

    Chrysler is recalling certain 2017-2023 Pacifica Plug-In Hybrid vehicles due to a wiring connector short circuit that may cause unexpected engine shutdown and loss of drive power.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V619000·2022-08-11

    2022 Chrysler Pacifica windshield wipers may not function due to loose arm nuts

    Certain 2022 Chrysler Pacifica and Voyager vehicles have improperly tightened windshield wiper arm nuts, causing malfunction. This reduces driver visibility and increases crash risk. Dealers will tighten the nuts free of charge.

    Product
    CHRYSLER — CHRYSLER PACIFICA, VOYAGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V181000·2022-03-24

    2022 Chrysler Pacifica seat mounting latch defect recall

    Chrysler is recalling 2021-2022 Pacifica and 2021 Voyager vehicles because the second-row seat mounting latch may fail to secure the seat properly, increasing the risk of injury in a crash.

    Product
    CHRYSLER — CHRYSLER PACIFICA, VOYAGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V191000·2020-09-10

    Chrysler Recalls Jeep, Ram, and Dodge Vehicles for Rearview Camera Software Error

    Chrysler is recalling 319,610 vehicles because a software error can cause the rearview camera image to remain displayed after shifting out of reverse, increasing crash risk.

    Product
    JEEP — JEEP, CHRYSLER, RAM WRANGLER, PACIFICA, GLADIATOR, RENEGADE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V886000·2019-12-12

    Chrysler Recalls 2018-2019 Pacifica for Rearview Camera Software Error

    Chrysler is recalling 2018-2019 Pacifica minivans because a software error may keep the rearview camera image on the radio display after shifting out of reverse, potentially distracting the driver.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V524000·2018-08-09

    Chrysler, Jeep, and Ram Vehicles Recalled for Powertrain Control Module Defect

    FCA US LLC is recalling specific 2017-2019 Chrysler, Jeep, Ram, Dodge, and Fiat vehicles because a faulty voltage regulator chip may cause the vehicle to stall or fail to start.

    Product
    CHRYSLER — CHRYSLER, RAM, JEEP PACIFICA, PACIFICA PLUG-IN HYBRID, 1500, RENEGADE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V049000·2018-01-11

    Chrysler Recalls 2017 Pacifica Vehicles for Engine Stall Risk

    Chrysler is recalling 2017 Pacifica vehicles with 3.6L engines because software issues may cause the engine to stall, increasing crash risk.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V824000·2017-12-21

    Chrysler Recalls Vehicles with Defective Kidde Fire Extinguishers

    Chrysler is recalling various Dodge, Jeep, and RAM vehicles equipped with specific Kidde fire extinguishers that may clog or detach, posing injury risks.

    Product
    DODGE — DODGE, RAM, JEEP DURANGO, CHALLENGER, RAM 1500, 5500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V542000·2017-08-31

    Chrysler Recalls 2017-2018 Pacifica Vehicles Due to Seat Belt Defect

    Chrysler is recalling 2017-2018 Pacifica minivans with 8-passenger seating because a seat belt buckle may cause the left outboard belt to unlatch.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V490000·2016-06-30

    Chrysler Recalls 2017 Pacifica Vehicles for Seat Belt Stow Clip Defect

    Chrysler is recalling 2017 Pacifica vehicles because a center overhead seat belt stow clip may fracture, preventing seat belt use and increasing injury risk in a crash.

    Product
    CHRYSLER — CHRYSLER PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide

NHTSA crash-test safety rating

Federal 5-Star Safety Rating from crash testing. This is a separate government program from the recall(s) above — a high star rating says nothing about whether a specific recall has been fixed, and a recall says nothing about crash-test performance.

Source: NHTSA New Car Assessment Program (NCAP), a federal crash-test program — not a recall record.

Wider context for this vehicle

Beyond the official recalls above. These are third-party figures derived from NHTSA complaint data — useful signal, but not part of our verified recall record.

Federal investigations — 3 open

  • PE25009 Preliminary Evaluation · open · steering:electric power assist system
  • RQ24004 Recall Query · open · electrical system:wiring
  • RQ24001 Recall Query · open · electrical system:propulsion system:traction battery
  • PE22008 Preliminary Evaluation · power train
  • DP17003 Defect Petition · engine and engine cooling:engine:gasoline
  • EA08006 Engineering Analysis · electrical system

Complaint clusters with no matching recall

  • 2017 · powertrain — 425 complaints, median 29,000 mi
    Includes 2 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2017 · steering — 289 complaints, median 44,000 mi
  • 2005 · engine — 273 complaints, median 84,083 mi
    Includes 7 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2005 · body — 268 complaints, median 118,000 mi
  • 2017 · engine — 237 complaints, median 26,000 mi
    Includes 2 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.

Technical service bulletins

826 manufacturer service bulletins across 14 model years. A TSB is repair guidance to dealers, not a safety recall.

Third-party reliability score

  • 2026: 4.5/5
  • 2025: 3.3/5 · 30 complaints · most complained-of: airbags
  • 2024: 3.0/5 · 47 complaints · most complained-of: powertrain
  • 2023: 2.4/5 · 155 complaints · most complained-of: powertrain
  • 2022: 2.7/5 · 218 complaints · most complained-of: powertrain

This is ProblemsByVin’s own published heuristic (1 worst – 5 best), not an official rating and unrelated to our severity scale.

Data on this panel comes from ProblemsByVin, derived from US NHTSA owner complaints and recalls, and licensed CC BY 4.0. It is not published by a federal agency and is not part of our verified recall record.

← Back to all Chrysler models