The Recall Desk

Vehicle

Ic Bus Cesb

62 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–62 of 62

  • Severity pendingNHTSA·26V460000·2026-07-16

    IC Bus EVSB and CESB school buses recalled for structural body joint defects

    International Motors, LLC is recalling certain 2025-2027 IC Bus EVSB and CESB school buses due to insufficient epoxy coverage on body joints. This defect may cause panels to separate during a crash.

    Product
    IC BUS — IC BUS CESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V364000·2026-06-04

    IC Bus CESB School Buses Recalled for Wheelchair Retract Defect

    International Motors is recalling 2027 IC Bus CESB school buses because wheelchair retractors may not lock, increasing injury risk.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V168000·2026-03-19

    IC Bus school bus body joints may lack sufficient epoxy coverage

    International is recalling certain 2023-2027 IC Bus CESB and 2025-2027 IC Bus EVSB school buses because the body panel joint may have been attached without sufficient epoxy coverage.

    Product
    IC BUS — IC BUS EVSB, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V111000·2026-02-26

    IC Bus school bus brake lines may be damaged and leak

    International is recalling certain 2023-2027 IC Bus CESB school buses because the brake lines may have been installed with incorrect hardware, which can damage the lines and cause a leak.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V646000·2025-09-25

    School bus tire can damage air line activating the parking brake

    International is recalling certain 2024-2026 IC Bus CESB school buses because a tire may contact and damage the air dryer discharge line, causing an air leak that unintentionally applies the parking brake.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V522000·2025-08-12

    IC Bus school bus parking brake springs may corrode and break

    International is recalling certain 2024-2026 IC Bus CESB and 2025 EVSB school buses because the parking brake tension spring may corrode and break, disengaging the parking brake. 3,230 buses affected.

    Product
    IC BUS — IC BUS CESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V503000·2025-08-06

    IC Bus CESB School Buses Brake Pressure Switch Fire Risk Recall

    International Motors is recalling certain 2016–2024 IC Bus CESB school buses because the brake pressure switch assembly may leak brake fluid into electrical components, causing a short circuit and fire risk while driving or parked.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V323000·2025-05-15

    School bus parking brake can release while wheelchair lift is deployed

    International is recalling certain 2025-2026 IC Bus CESB school buses because the parking brake can be released while the wheelchair platform lift is deployed, failing FMVSS 403.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V266000·2025-04-22

    IC school bus driver seat belt anchor bolts may come loose

    International is recalling certain 2025-2026 IC CESB and 2025 EVSB school buses because the driver's seat belt anchor bolt may come loose, so the belt may not restrain the driver in a crash.

    Product
    IC BUS — IC BUS CESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V750000·2024-10-02

    School buses recalled for brake caliper mounting bolt defect

    Navistar is recalling 2024-2025 IC Bus school buses because brake caliper mounting bolts may not be properly tightened, allowing the brake caliper to detach and cause loss of braking ability. Owner notification was sent in November 2024.

    Product
    IC BUS — IC BUS CESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V463000·2024-06-20

    Navistar Recalls 2025 IC Bus CE School Buses for Tie Rod Defect

    Navistar is recalling 2025 IC Bus CE school buses because incorrectly heat-treated tie rod assemblies may break, potentially causing loss of steering control.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V341000·2024-05-15

    Navistar Recalls 2024-2025 IC Bus School Buses for Brake Defect

    Navistar is recalling 2024-2025 IC Bus school buses because a faulty valve module may cause park brake failure or unexpected engagement.

    Product
    IC BUS — IC BUS CESB, CE SBUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V870000·2022-11-23

    2023 IC Bus Models Suspension and Steering Fastener Recall

    Navistar is recalling 2023 IC Bus EV, CE, and RE models due to improperly heat-treated fasteners in suspension and steering joints. These fasteners may lose tension and cause steering instability, increasing crash risk.

    Product
    IC BUS — IC BUS RESB, EV, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V869000·2022-11-23

    International and IC Bus vehicles recalled for defective suspension and steering fasteners

    Navistar is recalling certain 2021-2023 International trucks and IC Bus vehicles because hex flange lock nuts in suspension and steering joints were improperly heat treated and may lose tension, creating a risk of steering instability.

    Product
    IC BUS — IC BUS, INTERNATIONAL TC, CESB, 1300 FBC, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V429000·2022-06-16

    2023 IC CE School Bus Steering Gear May Fracture, Causing Loss of Control

    Navistar is recalling certain 2022-2023 IC CE School Buses because their steering gears may have been assembled incorrectly and could fracture, causing a loss of steering control and increasing crash risk.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V367000·2022-05-23

    School buses recalled for steering wheels that may loosen and detach

    Navistar is recalling certain 2022-2023 IC BUS school buses. The steering wheel retaining nut may have been tightened incorrectly, allowing the steering wheel to loosen or detach. Owners should not drive their vehicles until repaired.

    Product
    IC BUS — IC BUS CE, RESB, RE, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V837000·2021-10-25

    2020-2023 IC Bus School Buses Recalled for Engine Shut Down Risk

    Navistar is recalling 2020-2023 IC Bus CESB school buses due to an engine control module defect that may cause unexpected engine shutdown while driving, increasing the risk of crashes and emergency evacuation situations.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V220000·2020-04-17

    Navistar Recalls IC Bus CE School Buses Due to Fuel Heater Fire Risk

    Navistar is recalling 2017-2021 IC Bus CE school buses because the electric fuel heater may overheat, melt plastic, and cause a fire or engine stall.

    Product
    IC BUS — IC BUS CE, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V373000·2019-05-15

    Navistar Recalls IC Bus School Buses Due to Rear Brake Drag

    Navistar is recalling 2016-2020 IC Bus school buses because the driver-side rear brakes may drag, potentially causing fire or injury.

    Product
    IC BUS — IC BUS RECB, CE, CESB, RESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V374000·2019-05-15

    Navistar Recalls 2017 IC CE Transit Buses for Brake Drag

    Navistar is recalling 2017 IC CE transit buses because the driver-side rear brakes may drag, posing a fire and injury risk.

    Product
    IC BUS — IC BUS CESB, CE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V217000·2019-03-20

    Navistar Recalls IC Bus School Buses Due to Fuel Heater Fire Risk

    Navistar is recalling 2017-2020 IC Bus school buses because fuel heater wiring may overheat, melt plastic, and cause a fire or engine stall.

    Product
    IC BUS — IC BUS CESB, CE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V216000·2019-03-20

    Navistar Recalls 23,122 Vehicles for Fuel Heater Fire Risk

    Navistar is recalling 23,122 vehicles because an electric fuel heater may overheat, melt plastic, and cause a fire or engine stall.

    Product
    IC BUS — IC BUS, INTERNATIONAL CE, TC, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V821000·2018-11-20

    Navistar Recalls 2019-2020 IC Bus CE School Buses for Brake Line Defect

    Navistar is recalling 187 IC Bus CE school buses from 2019-2020 because an improperly routed brake air line may kink, causing the vehicle to pull right or disabling anti-lock brakes.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V598000·2018-09-07

    Navistar Recalls 2019 IC Bus School Buses Due to Brake Defect

    Navistar is recalling 2019 IC Bus CE and RE school buses because a parking brake component may be improperly crimped, causing air leaks and increased stopping distances.

    Product
    IC BUS — IC BUS CESB, RESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V290000·2018-05-03

    Navistar Recalls 2019 IC Bus CE School Buses Due to Brake Line Routing

    Navistar is recalling 2019 IC Bus CE school buses because an improperly routed air supply line may cause unintentional parking brake modulation, increasing crash risk.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V659000·2017-10-18

    Navistar Recalls 2016-2017 IC Bus School Buses for Seat Belt Defect

    Navistar is recalling 2016-2017 IC Bus school buses because the seat belt buckle mount rod can fracture under load, increasing injury risk in a crash.

    Product
    IC BUS — IC BUS CESB, RESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V580000·2017-09-20

    Navistar Recalls 2016 IC Bus CE School Buses for Steering Defect

    Navistar is recalling 2016 IC Bus CE school buses because a steering component may loosen, potentially causing a loss of steering and increasing crash risk.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V579000·2017-09-20

    Navistar Recalls 2018-2019 IC Bus CE School Buses for Brake Hose Routing

    Navistar is recalling 2018-2019 IC Bus CE school buses because the hydraulic brake hose may contact the tire, potentially causing fluid leaks and reduced braking performance.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V257000·2017-04-18

    Navistar Recalls 2016-2018 IC Bus CE School Buses for Fire Risk

    Navistar is recalling 336 school buses because an unfused electrical circuit in the heater booster pump may increase the risk of a fire.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V765000·2016-10-21

    Navistar Recalls School Buses with Defective Wheelchair Lifts

    Navistar is recalling certain 2015-2017 IC Bus school buses equipped with specific Ricon wheelchair lifts. The defect may cause the lift platform to fall out of the vehicle, increasing injury risk.

    Product
    IC BUS — IC BUS RESB, CESB, CASB, AE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V166000·2015-03-23

    Navistar Recalls 2015-2016 IC School Buses for Brake Fire Risk

    Navistar is recalling specific 2015-2016 IC school buses because defective air brake actuators may cause dragging brakes and wheel end fires.

    Product
    IC BUS — IC BUS CASB, CESB, RESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V084000·2015-02-11

    Navistar Recalls 2015-2016 IC CE School Buses for Fuel Leak Risk

    Navistar is recalling 6,302 model year 2015-2016 IC CE school buses because the powertrain wiring harness may contact a high-pressure fuel line, potentially causing a fuel leak and fire.

    Product
    IC BUS — IC BUS CASB, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V476000·2012-09-27

    Navistar Recalls IC School Buses Due to Oil Line Leak Risk

    Navistar is recalling 2006-2011 IC school buses because a high-pressure oil line may leak or rupture, potentially causing an engine stall or fire.

    Product
    IC BUS — IC BUS FESB, RESB, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V783000·2025-11-13

    School buses recalled because the weight rating may be exceeded when full

    International Motors is recalling 142 model year 2023-2027 IC Bus CESB school buses because the bus may exceed its Gross Vehicle Weight Rating when fully occupied with full tanks.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V640000·2025-09-25

    International Recalls 2026 IC Bus CESB School Buses for Wiper Defect

    International Motors is recalling 2026 IC Bus CESB school buses because a weld failure may prevent the left-side wiper from working, increasing crash risk.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V580000·2025-09-04

    IC Bus School Buses Recalled for Structural Reinforcement Defect

    International Motors is recalling certain 2016-2026 IC Bus CESB and 2016-2021 RESB school buses due to missing or incomplete underfloor reinforcement that may compromise crash safety. Owners should contact a dealer for free inspection and installation.

    Product
    IC BUS — IC BUS CESB, RESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V176000·2025-03-20

    IC school bus low beams turn off with high beams

    International is recalling certain 2025-2026 IC Bus CESB school buses with halogen headlights because activating the high beams turns the low beams off, failing FMVSS 108.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V398000·2023-06-02

    IC Bus CESB school buses recalled for brake pressure switch fire risk

    Navistar is recalling certain IC Bus CESB school buses with brake pressure switch assemblies that may leak brake fluid and cause electrical short-circuits, creating a fire risk while driving or parked.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V370000·2023-05-25

    2022-2024 International Trucks: ABS Warning Light Fails to Illuminate

    Navistar is recalling certain 2021-2024 International trucks and buses whose anti-lock brake system warning light fails to illuminate when malfunctions occur. Drivers will not be alerted to brake system problems, increasing the risk of crashes.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS LONESTAR, RH, LT, HX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V371000·2023-05-25

    IC Bus school buses recalled for ABS warning light failure

    IC Bus school buses (2021–2024) are being recalled because the anti-lock brake system warning light fails to illuminate during malfunctions, preventing drivers from being alerted and increasing crash risk.

    Product
    IC BUS — IC BUS CESB, RESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V065000·2023-02-10

    2022-2024 IC Bus School Buses Roof Panel Joint Strength Defect Recall

    Navistar is recalling certain 2022-2024 IC Bus school buses because roof panels may have insufficient joint strength and could separate during a crash, increasing injury risk. Dealers will add fasteners to secure the joints at no cost.

    Product
    IC BUS — IC BUS RESB, CESB, EV, CE SBUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V909000·2022-12-08

    School buses recalled for incorrectly tightened rear axle fasteners

    Navistar is recalling certain 2023-2024 IC BUS school buses due to fasteners on the rear axle that may have been tightened incorrectly. This can allow the rear axle to shift, reducing vehicle control and increasing crash risk.

    Product
    IC BUS — IC BUS CESB, RESB, EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V872000·2022-11-23

    2023 IC BUS CESB Fuel Vapor Line May Leak, Creating Fire Risk

    Navistar is recalling 196 model-year 2023 IC BUS CESB buses due to defective fuel vapor lines. Without proper heat shielding, the lines may leak when exposed to exhaust heat, posing a fire risk.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V610000·2022-08-10

    2023 IC BUS CESB School Buses Engine Control Module Stall Risk

    Navistar is recalling certain 2023 IC CE school buses because the engine control module may experience an internal electrical short-circuit, causing the engine to stall unexpectedly. An unexpected engine stall increases the risk of a crash.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V283000·2022-04-27

    School buses missing warning label for inoperative collision mitigation system

    Navistar is recalling certain 2022-2023 IC BUS school buses because the warning label for the inoperative collision mitigation system may be missing. Drivers may not be aware the safety system is not functioning.

    Product
    IC BUS — IC BUS RESB, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V450000·2021-06-15

    2022 IC Bus school buses lack required emergency exit windows

    Navistar is recalling certain 2014–2022 IC Bus school buses that lack adequate emergency exit windows required by federal safety standards. The deficiency could delay passenger evacuation during emergencies.

    Product
    IC BUS — IC BUS CASB, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V534000·2019-07-17

    Navistar Recalls 2020 IC CE School Buses Due to Electrical Overload

    Navistar is recalling 2020 IC CE school buses because an electrical overload in the Body Control Module may cause the engine to start unexpectedly, increasing injury risk during service.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V563000·2018-08-24

    Navistar Recalls 2015-2019 IC Bus School Buses Due to Wheelchair Lift Defect

    Navistar is recalling 2015-2019 IC Bus school buses equipped with specific wheelchair lifts because a component may fail, allowing the platform to rise too high and increasing injury risk.

    Product
    IC BUS — IC BUS CESB, CASB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V315000·2018-05-15

    Navistar Recalls 2018-2019 IC Bus School Buses for Emergency Window Defect

    Navistar is recalling 7,859 IC Bus school buses because the emergency window release mechanism may be difficult to open, potentially hindering exit during an emergency.

    Product
    IC BUS — IC BUS CESB, RESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V124000·2018-02-20

    Navistar Recalls 2016-2019 IC Bus CE School Buses for Relay Defect

    Navistar is recalling 2016-2019 IC Bus CE school buses with 8.8L LPG engines because a relay may fail, causing the fuel pump to stop and the bus to stall.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V837000·2016-11-18

    Navistar Recalls IC Bus School Buses Due to Heater Hose Defect

    Navistar is recalling specific IC Bus school buses because a heater hose may split, leaking hot coolant into the driver's foot area and increasing the risk of burns or crashes.

    Product
    IC BUS — IC BUS CESB, CASB, CE, BE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V091000·2016-02-18

    Navistar Recalls 2016-2017 IC CE School Buses for Hood Strap Defect

    Navistar is recalling 2016-2017 IC CE school buses because hood straps may elongate, allowing the hood to open unexpectedly during braking and obstructing the driver's vision.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V320000·2013-07-23

    Navistar Recalls IC School Buses for Flip Seat Pinch Hazard

    Navistar is recalling certain IC school buses equipped with C. E. White Inc. flip seats due to a risk of foot or toe pinch injuries.

    Product
    IC BUS — IC BUS, IC RESB, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V258000·2012-06-05

    Navistar Recalls IC Bus CESB School Buses Due to Wheelchair Lift Defect

    Navistar is recalling certain 2007, 2009, and 2011 IC Bus CESB school buses because wheelchair lift roll stop latches may become bent or misaligned, posing a fall risk.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all Ic Bus models