The Recall Desk

Vehicle

International Rh

27 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–27 of 27

  • Severity pendingNHTSA·25V817000·2025-11-25

    International truck control units can lose ABS and stability control

    International is recalling certain 2016-2026 trucks with Bendix control units because electrical noise may cause the ECU to misprocess commands or stop working, disabling ABS and stability control.

    Product
    INTERNATIONAL — INTERNATIONAL MV, RH, LONESTAR, 8600
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V806000·2025-11-20

    International trucks may stay in gear with the parking brake applied

    International is recalling certain 2023-2026 LT and RH vehicles because the auto neutral function may not recognise that the parking brake has been applied, leaving the transmission in gear.

    Product
    INTERNATIONAL — INTERNATIONAL RH, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V781000·2025-11-13

    Trucks recalled because a clogged valve can keep the brakes engaged

    International Motors is recalling 1,303 model year 2023-2026 LT and 2024-2025 RH trucks because a clogged Hill Start Assist exhaust port may delay or prevent release of the service brakes.

    Product
    INTERNATIONAL — INTERNATIONAL LT, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V501000·2025-08-05

    2024–2026 International LT and 2025 RH Trucks Service Brake Defect

    International Motors is recalling certain 2024–2026 LT and 2025 RH trucks because the Hill Start Assist exhaust port may clog, preventing brake release and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LT, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V818000·2024-10-31

    International truck electronic control units can lose ABS and stability control

    International is recalling certain 2021-2025 trucks with Bendix EC80 control units because electrical noise may cause the ECU to misprocess commands or stop working, disabling ABS and stability control.

    Product
    INTERNATIONAL — INTERNATIONAL MV, RH, LT, HX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V556000·2024-07-25

    Second Navistar recall covers incorrectly heat treated tie rod ball studs

    A second Navistar recall covers certain 2025 International HV, HX, LT, MV and RH vehicles whose tie rod ball studs may have been incorrectly heat-treated. 573 units affected.

    Product
    INTERNATIONAL — INTERNATIONAL HX, LT, RH, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V462000·2024-06-20

    International truck tie rod ball studs were incorrectly heat treated

    Navistar is recalling certain 2025 International HV, LT, MV and RH trucks because tie rod ball studs may have been incorrectly heat-treated and can break. 116 units affected.

    Product
    INTERNATIONAL — INTERNATIONAL RH, HV, MV, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V088000·2024-02-08

    2024 International Trucks Steering Defect May Cause Loss of Control

    Navistar recalls 2024-2025 International trucks and 2024 IC Bus commercial buses due to steering gear assemblies that may be incorrectly assembled, potentially causing loss of steering control.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS HX, MV, HV, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V869000·2022-11-23

    International and IC Bus vehicles recalled for defective suspension and steering fasteners

    Navistar is recalling certain 2021-2023 International trucks and IC Bus vehicles because hex flange lock nuts in suspension and steering joints were improperly heat treated and may lose tension, creating a risk of steering instability.

    Product
    IC BUS — IC BUS, INTERNATIONAL TC, CESB, 1300 FBC, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V255000·2020-05-07

    Navistar Recalls 2018-2020 International Trucks Due to Engine Defect

    Navistar is recalling 2018-2020 International LT and 2019-2020 RH trucks because a wrist pin bushing failure may cause unexpected engine shutdown and increase crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LT, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V826000·2018-11-21

    Navistar Recalls 2018-2019 International Trucks for Clutch Assembly Defect

    Navistar is recalling certain 2018-2019 International trucks because a clutch component may fail, causing unintended vehicle movement and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL RH, MV, LONESTAR, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V597000·2018-09-07

    Navistar Recalls 2019 International and IC Bus Vehicles for Brake Defect

    Navistar is recalling 2,089 2019 International and IC Bus vehicles because a brake chamber defect may cause air leaks, increasing stopping distance and crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS LT, HX, WORKSTAR, DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V174000·2017-03-14

    Navistar Recalls International Trucks Due to Air Dryer Bracket Fracture Risk

    Navistar is recalling 2016-2018 International heavy diesel trucks because a mounting bracket may fracture, causing air leaks and increased stopping distance.

    Product
    INTERNATIONAL — INTERNATIONAL PROSTAR, LONESTAR, LT, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V516000·2026-08-06

    International Recalls 2027 Trucks Due to Wiper Nut Loosening Risk

    International is recalling 2027 HV, HX, LT, MV, and RH trucks because a wiper nut may loosen, causing wipers to disconnect and reducing visibility.

    Product
    INTERNATIONAL — INTERNATIONAL HX, HV, MV, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·25V276000·2025-04-24

    International truck wiper linkage can separate causing wipers to fail

    International is recalling certain 2025-2026 HV, HX, LT, MV, RH and 2025 EMV vehicles because the linkage connecting the right-side wiper arm to the motor may separate, causing the wipers to fail.

    Product
    INTERNATIONAL — INTERNATIONAL LT, HV, HX, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V370000·2023-05-25

    2022-2024 International Trucks: ABS Warning Light Fails to Illuminate

    Navistar is recalling certain 2021-2024 International trucks and buses whose anti-lock brake system warning light fails to illuminate when malfunctions occur. Drivers will not be alerted to brake system problems, increasing the risk of crashes.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS LONESTAR, RH, LT, HX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V353000·2023-05-18

    Navistar International trucks recalled for inadequate back-up light visibility

    Navistar is recalling certain International trucks (2000-2024 model years) for inadequate back-up light visibility when reversing. Low visibility may not alert other drivers, increasing crash risk. Dealers will replace rear stop/turn signal lights free of charge.

    Product
    INTERNATIONAL — INTERNATIONAL MV, 9400I, 9100I, 9200I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V220000·2023-03-30

    International LT and RH Trucks Engine Control Module Software Issue

    Navistar is recalling 2021–2024 International LT and RH trucks because the engine control module may become unresponsive to throttle pedal input, causing the vehicle to unexpectedly slow to idle speed while driving, which increases crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LT, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V171000·2023-03-16

    2023 International Trucks Recalled for Parking Brake Defect

    Navistar is recalling certain 2023 International trucks because the Intellipark Parking Valve Module can fail to engage the parking brake, risking vehicle rollaway. The manufacturer will replace the defective component.

    Product
    INTERNATIONAL — INTERNATIONAL LT, HV, HX, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V119000·2023-02-23

    International commercial trucks recalled for park brake software defect

    Navistar is recalling 2018-2022 International trucks with a software defect that may prevent the park brake from holding during power-take-off operation, risking unexpected vehicle movement.

    Product
    INTERNATIONAL — INTERNATIONAL MV, HV, RH, HX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V691000·2022-09-15

    International commercial vehicles recalled for engine connecting rod failure

    Navistar is recalling certain 2018-2021 International HV, HX, LT, and RH vehicles because connecting rod wrist pins may crack, causing engine failure. This could lead to engine shutdown and increase the risk of a crash.

    Product
    INTERNATIONAL — INTERNATIONAL HV, RH, LT, HX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V428000·2022-06-16

    2022-2023 International Commercial Trucks and Buses Steering Gear Defect

    Navistar is recalling 2022-2023 International commercial vehicles with defective steering gears that may fracture and cause loss of steering control. Contact your dealer or Navistar at 1-800-448-7825 for inspection and free replacement.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS HX, LT, RH, LONESTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V281000·2021-04-22

    International RH and LT trucks recalled for engine connecting rod failure

    Navistar is recalling certain 2019-2021 International LT and RH trucks due to wrist pin cracks that can cause connecting rod failure and engine stalls. Affected owners should contact their dealer for free repair.

    Product
    INTERNATIONAL — INTERNATIONAL LT, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V226000·2021-04-01

    2021 International RH and LT Vehicles Parking Brake Defect

    Certain 2021 International RH and LT vehicles have a defective spring brake chamber that may allow the parking brake to malfunction, increasing crash risk. Navistar will replace the defective brake chambers at no cost.

    Product
    INTERNATIONAL — INTERNATIONAL RH, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V227000·2021-04-01

    2021 International Trucks Recalled for Air Brake Check Valve Manufacturing Defect

    Navistar recalls 2021 International trucks for defective air brake check valves that may cause unintended brake application and increase crash risk. The SC-3 valve's retainer is not properly seated.

    Product
    INTERNATIONAL — INTERNATIONAL RH, LT, HV, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all International models