The Recall Desk

Vehicle

E-One Cyclone Ii

43 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–43 of 43

  • Severity pendingNHTSA·26V652000·2026-10-06

    E-One Recalls Fire Trucks Due to Wiring Overheat Risk

    E-One is recalling specific Typhoon N, Cyclone N, and Cyclone II fire trucks because a loose power supply may cause wiring to overheat, increasing fire risk.

    Product
    E-ONE — E-ONE TYPHOON N, CYCLONE N, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V646000·2024-08-30

    E-One Recalls Cyclone and Typhoon Vehicles Due to Crossmember Defect

    E-One is recalling 2022-2024 Cyclone and Typhoon vehicles because a broken engine crossmember can damage the cooling fan, potentially causing an engine stall and increasing crash risk.

    Product
    E-ONE — E-ONE CYCLONE II, CYCLONE N, TYPHOON N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V016000·2024-01-12

    E-One Recalls 280 Fire Apparatus Due to Steering Bracket Defect

    E-One is recalling 280 fire apparatus vehicles because an incorrectly machined steering assist bracket may reduce hydraulic force, increasing steering effort and crash risk.

    Product
    E-ONE — E-ONE TYPHOON N, CYCLONE E, CYCLONE N, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V006000·2024-01-08

    E-One Recalls Fire Trucks Due to Electrical Fire Risk

    E-One is recalling 408 fire trucks because a wiring defect may cause electrical circuits to overheat and start a fire.

    Product
    E-ONE — E-ONE TYPHOON N, COMMERCIAL, CYCLONE E, CYCLONE N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V788000·2022-10-20

    E-One Recalls 2022 Fire Apparatus Due to Tie Rod Clamp Cracking

    E-One is recalling 2022 Typhoon N, Cyclone II, and Cyclone N vehicles because improperly heat-treated tie rod clamps may crack, risking sudden loss of steering.

    Product
    E-ONE — E-ONE TYPHOON N, CYCLONE II, CYCLONE N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V538000·2022-07-26

    E-One Fire Trucks Recalled for Electrical Connection Overheating Risk

    E-One is recalling specific 2019-2022 fire trucks because a loose electrical connection may cause the load center to overheat, increasing fire risk.

    Product
    E-ONE — E-ONE CYCLONE II, TYPHOON, TYPHOON N, CYCLONE N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V952000·2021-12-09

    E-One Recalls Fire Trucks Due to Fuel Tube Cracking Risk

    E-One is recalling specific 2019-2021 Quest II, Typhoon, and Cyclone models because fuel tubes may crack, causing high-pressure leaks and fire risks.

    Product
    E-ONE — E-ONE QUEST II, TYPHOON, CYCLONE II, CYCLONE N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V332000·2021-05-11

    E-One Fire Apparatus Recalled for Fuel Rail Leak Fire Risk

    E-One Incorporated is recalling 2017-2021 fire apparatus vehicles because a defective sealing washer may cause a fuel leak, increasing the risk of fire.

    Product
    E-ONE — E-ONE TYPHOON N, CYCLONE II, CYCLONE N, QUEST II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V598000·2019-08-14

    E-One Fire Trucks Recalled for Front Shock Separation Risk

    E-One is recalling specific Typhoon, Quest, and Cyclone II fire trucks because front shocks may separate, potentially damaging steering components and increasing crash risk.

    Product
    E-ONE — E-ONE TYPHOON, QUEST, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V747000·2018-10-22

    E-One Recalls 2012-2015 Emergency Vehicles Due to Fire Risk

    E-One is recalling 2012-2015 Typhoon, Cyclone II, and Cyclone III emergency vehicles because a melting relay in the HVAC system can increase the risk of a fire.

    Product
    E-ONE — E-ONE TYPHOON, CYCLONE III, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V748000·2018-10-22

    E-One Recalls 2016-2018 Typhoon and Cyclone II Aerial Devices

    E-One is recalling 2016-2018 Typhoon and Cyclone II aerial devices because a torque rod tower may crack, potentially affecting vehicle handling and increasing crash risk.

    Product
    E-ONE — E-ONE CYCLONE II, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V171000·2018-03-15

    E-One Recalls Typhoon, Cyclone II, and Quest II Vehicles for Spindle Defect

    E-One is recalling 2008-2015 Typhoon, Cyclone II, and Quest II vehicles because front axle spindles may crack and fail, potentially causing a wheel to separate.

    Product
    E-ONE — E-ONE TYPHOON, CYCLONE II, QUEST II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V056000·2018-01-09

    E-One Emergency Vehicles Recalled for Electrical Fire Risk

    E-One is recalling 2005-2010 emergency vehicles because loose electrical connections at the transfer switch may cause excessive heat and increase the risk of a fire.

    Product
    E-ONE — E-ONE CYCLONE II, CYCLONE III, TYPHOON, F550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V231000·2017-04-05

    E-One Recalls Emergency Vehicles Due to Front Suspension Ball Joint Defect

    E-One is recalling 2013-2016 Quest, Typhoon, and Cyclone II emergency vehicles because front suspension ball joints can loosen and separate, potentially causing a loss of steering control.

    Product
    E-ONE — E-ONE QUEST, TYPHOON, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V646000·2015-10-13

    E-One Emergency Vehicles Recalled for Disconnected Air Bag Harness

    E-One is recalling 2014-2015 Cyclone II, Typhoon, and Quest emergency vehicles because the front air bag harness may be disconnected, preventing deployment in a crash.

    Product
    E-ONE — E-ONE CYCLONE II, TYPHOON, QUEST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V598000·2015-09-24

    E-One Recalls 2013-2014 Emergency Vehicles Due to Suspension Defect

    E-One is recalling 2013-2014 Typhoon, Cyclone II, and Quest emergency vehicles because loose front suspension ball joints could separate, causing loss of steering control.

    Product
    E-ONE — E-ONE QUEST, TYPHOON, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V145000·2013-04-17

    E-One Recalls Cyclone II Fire Trucks Due to Brake Fire Risk

    E-One is recalling 2011-2013 Cyclone II fire fighting vehicles because brake chambers may leak, causing brakes to drag and overheat, which could lead to a fire.

    Product
    E-ONE — E-ONE CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V443000·2011-08-17

    E-One Fire Fighting Chassis Recalled for Exhaust Clamp Failure Risk

    E-One is recalling certain 2010-2011 fire fighting chassis due to a defect in the exhaust system clamp that could cause carbon monoxide poisoning or fire.

    Product
    E-ONE — E-ONE QUEST, TYPHOON, CYCLONE II, TRADITION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V225000·2010-05-26

    E-ONE Fire Trucks Recalled for Engine Shutdown Risk

    E-ONE is recalling 2008-2009 Cyclone II and Quest fire trucks due to a software defect that may cause unexpected engine shutdowns during rescue operations.

    Product
    E-ONE — E-ONE CYCLONE II, QUEST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V537000·2026-08-19

    E-One Recalls Fire Trucks Due to Hydraulic Valve Defect

    E-One is recalling specific 2025-2026 fire trucks because a hydraulic valve defect may prevent outriggers from extending or retracting, potentially delaying emergency response.

    Product
    E-ONE — E-ONE CYCLONE II, CYCLONE N, TYPHOON N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V760000·2024-10-11

    E-One Recalls Fire Trucks Due to Engine Crossmember Defect

    E-One is recalling 282 fire trucks because a broken engine crossmember can damage the cooling fan, causing an engine stall and increasing crash risk.

    Product
    E-ONE — E-ONE TYPHOON N, CYCLONE N, QUEST II, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V459000·2023-06-30

    E-One Recalls 2022-2023 Cyclone and Typhoon Vehicles for Transmission Cooler Defect

    E-One is recalling 2022-2023 Cyclone and Typhoon vehicles because insufficient welding on the transmission cooler may allow coolant to contaminate transmission fluid, risking drive power loss.

    Product
    E-ONE — E-ONE CYCLONE II, CYCLONE N, TYPHOON N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V372000·2022-05-24

    E-One Recalls 2022 Fire Trucks Due to Lighting Failure Risk

    E-One Incorporated is recalling 2022 Commercial, Cyclone 2, Cyclone N, and Typhoon N fire trucks because a defective circuit board can cause vehicle lighting to fail.

    Product
    E-ONE — E-ONE CYCLONE N, CYCLONE II, COMMERCIAL, TYPHOON N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V904000·2021-11-19

    E-One Recalls 2022 Cyclone and Typhoon Vehicles for Rear Axle Defect

    E-One is recalling 2022 Cyclone and Typhoon vehicles because a rear axle drive pinion may fracture, potentially engaging the parking brake and increasing crash risk.

    Product
    E-ONE — E-ONE TYPHOON, CYCLONE II, TYPHOON N, CYCLONE N
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V752000·2020-12-04

    E-One Recalls Emergency Vehicles Due to Display Lockup Risk

    E-One is recalling specific 2019-2021 emergency vehicles because LCD displays may lock up, potentially delaying emergency efforts.

    Product
    E-ONE — E-ONE COMMERCIAL, QUEST II, TYPHOON N, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V730000·2019-10-14

    E-One Recalls Emergency Vehicles Due to Starter Solenoid Circuit Defect

    E-One is recalling specific emergency vehicles because a missing diode in the starter solenoid circuit can damage the lock-out relay, potentially preventing the vehicle from starting.

    Product
    E-ONE — E-ONE TYPHOON, QUEST II, CYCLONE II, CHSH
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V592000·2019-08-13

    E-One Recalls 2019 Fire Trucks Due to Air Bag Defect

    E-One is recalling 2019 Cyclone II and Typhoon fire trucks because air bag cushions may detach and fail to inflate during a crash.

    Product
    E-ONE — E-ONE TYPHOON, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V606000·2018-09-11

    E-One Recalls 2017-2019 Emergency Vehicles Due to Brake Light Wiring Defect

    E-One is recalling 2017-2019 Typhoon, Cyclone II, and Quest II emergency vehicles because Whelen accessory brake lights may illuminate without the brake pedal being pressed.

    Product
    E-ONE — E-ONE TYPHOON, CYCLONE II, QUEST II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V019000·2018-01-09

    E-One Recalls 2013-2017 Emergency Vehicles Due to Starter Defect

    E-One is recalling 2013-2017 Quest II, Cyclone II, and Typhoon emergency vehicles because a missing diode may damage the starter lock-out relay, preventing the vehicle from starting.

    Product
    E-ONE — E-ONE QUEST II, CYCLONE II, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V739000·2017-11-20

    E-One Recalls Fire Trucks with Corroding Pressure Relief Valve Rings

    E-One is recalling 298 fire-fighting vehicles because corroding rings may cause pressure relief valves to open, reducing water pressure.

    Product
    INTERNATIONAL — INTERNATIONAL, E-ONE, KENWORTH 4400, 7400, QUEST, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V631000·2017-10-09

    E-One Recalls 2016-2017 Emergency Vehicles for Steering Defect

    E-One is recalling 2016-2017 Quest, Typhoon, and Cyclone II emergency vehicles because the power steering assist cylinder may not be properly tightened, increasing crash risk.

    Product
    E-ONE — E-ONE QUEST, TYPHOON, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V567000·2016-08-01

    E-One Recalls 2015-2016 Cyclone II and Typhoon Fire Trucks

    E-One is recalling 2015-2016 Cyclone II and Typhoon fire trucks because a transmission component may fail, preventing the vehicle from pumping water to fight fires.

    Product
    E-ONE — E-ONE CYCLONE II, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V443000·2016-06-16

    E-One Recalls Cyclone II and Typhoon Vehicles for Electrical Fire Risk

    E-One is recalling 2014-2016 Cyclone II and Typhoon vehicles because a power control module defect may cause a short circuit, leading to electrical damage or fire.

    Product
    E-ONE — E-ONE CYCLONE II, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V293000·2016-05-12

    E-One Recalls 2015-2016 Emergency Vehicles Due to Pump Strainer Defect

    E-One is recalling 140 model year 2015-2016 Cyclone II, Quest II, and Typhoon emergency vehicles because pump intake strainers may be improperly soldered.

    Product
    E-ONE — E-ONE CYCLONE II, QUEST II, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V217000·2014-04-18

    E-One Recalls 2013-2014 Fire Fighting Chassis Due to Software Defect

    E-One is recalling 112 model year 2013-2014 Typhoon, Quest, and Cyclone II fire fighting chassis because a software defect may cause brake lights to stay on or prevent idle raise.

    Product
    E-ONE — E-ONE TYPHOON, QUEST, CYCLONE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V601000·2013-11-29

    E-One Recalls 2013 Fire Fighting Vehicles for Seat Belt Defect

    E-One is recalling 2013 Quest, Cyclone II, and Typhoon fire fighting vehicles because seat belt buckles may fail to release, hindering emergency egress.

    Product
    E-ONE — E-ONE CYCLONE II, TYPHOON, QUEST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V564000·2011-12-01

    E-ONE Fire Trucks Recalled for Electronic Stability Control Defect

    E-ONE is recalling 2008-2011 Quest, Cyclone II, and Typhoon vehicles because the electronic stability control system may malfunction, increasing crash risk.

    Product
    E-ONE — E-ONE QUEST, CYCLONE II, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V357000·2011-07-13

    E-One Fire Fighting Vehicles Recalled for Door Handle Bracket Defect

    E-One is recalling 2010-2011 Tradition, Cyclone II, and Typhoon fire fighting vehicles because door handle brackets may rotate, causing doors to open during a crash.

    Product
    E-ONE — E-ONE TRADITION, CYCLONE II, TYPHOON
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all E-One models