The Recall Desk

Vehicle

Spartan Gladiator

60 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–60 of 60

  • Severity pendingNHTSA·20V203000·2020-04-08

    Spartan Gladiator and MetroStar Recalled for Park Brake Line Defect

    Marion Body Works is recalling 2019-2020 Spartan Gladiator and MetroStar vehicles because the park brake control line may loosen, potentially causing sudden deceleration and increasing crash risk.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V163000·2020-03-20

    SVI Trucks Recalls 2019-2020 Spartan Emergency Vehicles for Brake Defect

    SVI Trucks is recalling 2019-2020 Spartan MetroStar and Gladiator emergency vehicles because the park brake line may loosen, causing sudden deceleration.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V925000·2019-12-30

    Toyne Recalls 2018-2019 Spartan Metro Star and Gladiator Chassis

    Toyne Inc. is recalling 2018-2019 Spartan Metro Star and Gladiator chassis due to a brake relay valve defect that may increase stopping distance.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V874000·2019-12-10

    Spartan Emergency Response Vehicles Recalled for Brake Valve Defect

    Marion Body Works is recalling 2018-2019 Spartan Gladiator and Metro Star emergency response chassis because a brake relay valve defect may cause extended stopping distances.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V828000·2019-11-19

    Spartan Gladiator and Metrostar Recalled for Brake Control Line Defect

    Marion Body Works is recalling 2005-2020 Spartan Gladiator and Metrostar vehicles because air pressure control lines may not be protected, potentially causing unexpected brake application.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V523000·2019-07-12

    Spartan Gladiator and MetroStar Front Shock Separation Recall

    Spartan is recalling 2014-2020 Gladiator and MetroStar vehicles because front shocks may separate, potentially causing a loss of power steering assist and increasing crash risk.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V360000·2019-05-13

    Spartan Emergency Chassis Recalled for Brake Valve Defect

    Spartan Motors is recalling 2018-2020 emergency response and motor home chassis because a brake relay valve defect may increase stopping distance.

    Product
    SPARTAN — SPARTAN K3, K2, K4, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V338000·2019-04-30

    Spartan Gladiator Aerial Vehicles Recalled for Frame Cracks

    Spartan Motors is recalling 2004-2016 Gladiator aerial vehicles because cracks in the tiller frame may cause the device to fall, risking injury.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V440000·2018-06-29

    Spartan Gladiator Recall: Battery Cable Chafing May Increase Fire Risk

    Spartan Motors is recalling 2010-2019 Gladiator vehicles because a brittle battery cable sleeve can cause chafing and arcing, increasing the risk of a fire.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V350000·2018-05-29

    Spartan Emergency Vehicles Recalled for Missing Air Brake Safety Valve

    Spartan is recalling 2001-2018 emergency vehicles because a missing pressure protection valve could cause air brake failure.

    Product
    SPARTAN — SPARTAN DIAMOND, ADVANTAGE, GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V206000·2018-03-29

    Spartan Gladiator Recall for Front Axle Spindle Failure Risk

    Spartan Motors is recalling 2004-2007 Gladiator emergency response vehicles because front axle spindles may crack and fail, potentially causing a wheel to separate.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V403000·2017-06-27

    Spartan Recalls 2017-2018 Chassis Due to Fuel Pump Gear Slip Risk

    Spartan Motors is recalling 2017-2018 K3, K4, and Gladiator chassis because a fuel pump gear may slip, causing engine stalls that increase crash risk.

    Product
    SPARTAN — SPARTAN K3, GLADIATOR, K4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V351000·2017-05-31

    Spartan Recalls 2010-2014 Chassis Due to Starter Motor Fire Risk

    Spartan Motors is recalling 2010-2014 K2, K3, and Gladiator chassis because a starter motor component may break, causing overheating and increasing fire risk.

    Product
    SPARTAN — SPARTAN K3, GLADIATOR, K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V160000·2017-03-13

    Spartan Trucks Recalled for Front Suspension Ball Joint Separation Risk

    Spartan Motors is recalling specific 2011-2018 trucks because front suspension ball joints can loosen, potentially causing a loss of steering control.

    Product
    SPARTAN — SPARTAN K4, METROSTAR, K3, K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V688000·2016-09-23

    Spartan Gladiator Fire Apparatus Recalled for Tiller Frame Crack Risk

    Spartan Motors is recalling 2004-2010 Gladiator emergency response vehicles because the tiller frame may crack, potentially causing instability and injury.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V429000·2016-06-13

    Spartan Gladiator and K3 Motorhome Chassis Recalled for Engine Stall Risk

    Spartan is recalling 2017 Gladiator and K3 motorhome chassis due to a potential electrical short in the engine control module that could cause the engine to stall.

    Product
    SPARTAN — SPARTAN K3, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V687000·2015-10-21

    Spartan Gladiator Recall for Power Steering Fluid Overheating

    Spartan Motors is recalling 2009-2014 Gladiator and MetroStar vehicles because power steering fluid may overheat, causing the steering to lock unexpectedly.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V812000·2014-12-23

    Spartan Recalls 2013-2015 Motorhomes Due to Steering Linkage Defect

    Spartan Motors is recalling 277 model year 2013-2015 motorhomes and chassis cabs because steering linkage castle nuts may loosen, potentially causing a loss of steering control.

    Product
    SPARTAN — SPARTAN K2, MM, METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V747000·2014-11-24

    Spartan Trucks Recalled for Air Brake Valve Defect

    Spartan is recalling 2013-2015 trucks because damaged air brake valves may reduce braking performance or cause parking brakes to reapply, increasing crash risk.

    Product
    SPARTAN — SPARTAN NVS, GLADIATOR, DR, MM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V505000·2014-08-18

    Spartan Emergency Vehicles Recalled for Fuel Filter Defect

    Spartan is recalling 2013-2015 emergency vehicles and chassis because fuel filters may separate, causing the engine to stall without warning.

    Product
    SPARTAN — SPARTAN SB, GLADIATOR, METROSTAR, MM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V022000·2014-01-28

    Spartan Gladiator Emergency Vehicles Recalled for Engine Fan Shattering Risk

    Spartan Motors is recalling 2008-2011 Gladiator emergency vehicles because excessive vibration can cause the engine cooling fan to shatter, potentially injuring nearby individuals.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V628000·2013-12-18

    Spartan Emergency Vehicles Recalled for Front Suspension Weld Cracks

    Spartan Motors is recalling certain 2006-2010 emergency response vehicles because front suspension welds may crack, increasing the risk of a crash.

    Product
    SPARTAN — SPARTAN METROSTAR, ADVANTAGE, DIAMOND, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V066000·2013-02-28

    Spartan Metro Star and Gladiator Fire Trucks Recalled for Air Bag Defect

    Spartan Motors is recalling 2012-2013 Metro Star and Gladiator fire trucks because a short circuit in the air bag control module could cause unintended deployment.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V425000·2011-08-17

    Spartan Recalls 2010-2012 Recreational Vehicles Due to Exhaust Fire Risk

    Spartan is recalling certain 2010-2012 recreational vehicles because a faulty exhaust clamp bolt can fracture, allowing hot gases to vent and cause a fire.

    Product
    SPARTAN — SPARTAN GLADIATOR, MM, K2, K3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V187000·2011-03-21

    Spartan Gladiator and Metrostar Trucks Recalled for Brake Component Defect

    Spartan Chassis is recalling certain 2008-2011 Gladiator and 2010 Metrostar trucks because defective brake slack adjusters may crack, causing loss of braking.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V245000·2010-06-07

    Spartan Fire Apparatus Chassis Recalled for Brake Release Defect

    Spartan is recalling 2008-2010 Gladiator and Metrostar fire apparatus chassis because electronic stability control components slow service brake release, violating federal safety standards.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V210000·2010-05-14

    Spartan Fire Apparatus Chassis Recalled for Front Suspension Defect

    Spartan Chassis is recalling certain 2006-2009 fire apparatus chassis because front suspension brackets may crack or separate, potentially impairing steering.

    Product
    SPARTAN — SPARTAN ADVANTAGE, METROSTAR, DIAMOND, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V209000·2010-05-14

    Spartan Fire Apparatus Recalled for Electronic Stability Control Defect

    Spartan Chassis is recalling 468 model year 2008-2010 fire apparatus and ambulance chassis because the electronic stability control system may apply brakes incorrectly, potentially causing a crash.

    Product
    SPARTAN — SPARTAN METROSTAR, DIAMOND, FURION, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V181000·2010-05-03

    Spartan Gladiator Fire Apparatus Recalled for Engine Shutdown Risk

    Spartan is recalling 2007-2009 Gladiator fire apparatus vehicles because the engine may shut down unexpectedly, potentially hampering rescue operations.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V052000·2010-02-05

    Spartan Fire Apparatus Chassis Recalled for Seat Belt Anchor Defect

    Spartan Chassis is recalling specific fire apparatus chassis because seat belt anchorages may not meet federal safety standards, posing a risk of injury in a crash.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR, BARRON, DIAMOND
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V674000·2019-09-23

    Spartan Metrostar and Gladiator Recall for Air Brake Control Line Defect

    Spartan is recalling 2004-2020 Metrostar and Gladiator vehicles because unprotected air brake control lines may cause unexpected brake application and increase crash risk.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V932000·2018-12-26

    Spartan Metrostar and Gladiator Fire Apparatus Brake Recall

    Spartan is recalling 2011-2019 Metrostar and Gladiator fire apparatus vehicles due to a brake release delay that may hinder movement and increase crash risk.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V691000·2018-10-03

    Spartan Emergency Vehicles Recalled for Loose EMS Cabinet Fasteners

    Spartan Motors is recalling 2001-2019 MetroStar and Gladiator emergency vehicles because EMS cabinet fasteners may be the wrong size, posing a crash injury risk.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V424000·2018-06-25

    Spartan Emergency Vehicles Recalled for Fire Pump Solenoid Corrosion

    Spartan Motors is recalling 2009-2018 Gladiator and MetroStar emergency vehicles because internal corrosion in the fire water pump solenoid may cause loss of water pressure, increasing injury risk.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V722000·2017-11-16

    Spartan Recalls 2014-2017 Emergency Vehicles Due to Pressure Valve Defect

    Spartan Motors is recalling 2014-2017 Gladiator and MetroStar emergency vehicles because corroded rings may cause pressure relief valves to open, reducing water pressure for firefighting.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V676000·2016-09-19

    Spartan Emergency Response Vehicles Recalled for Power Steering Pump Defect

    Spartan Motors is recalling 2010-2017 K3, Gladiator, and Metrostar chassis due to a power steering pump defect that may cause intermittent loss of steering assist.

    Product
    SPARTAN — SPARTAN K3, GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V400000·2016-06-03

    Spartan Gladiator and MetroStar Emergency Vehicles Recalled for Pump Defect

    Spartan is recalling 2015 Gladiator and MetroStar emergency vehicles because improperly soldered pump strainers may break, potentially damaging the pump and reducing firefighting effectiveness.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V448000·2015-07-15

    Spartan Emergency Response Vehicles Recalled for Valve Stem Wear

    Spartan is recalling 2007-2015 emergency response vehicles because front wheel valve stems may rub against brake calipers, causing sudden tire deflation.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR, ADVANTAGE, DIAMOND
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V403000·2015-06-24

    Spartan Emergency Vehicles Recalled for Engine Cooling Fan Defect

    Spartan Motors is recalling 2010-2015 Furion, Gladiator, and Metrostar emergency vehicles because the engine cooling fan may crack and detach, posing an injury risk to nearby individuals.

    Product
    SPARTAN — SPARTAN GLADIATOR, FURION, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V664000·2014-10-22

    Spartan Gladiator Recall: Engine Cooling Fan May Break and Separate

    Spartan Motors is recalling 2010-2015 Gladiator vehicles because the engine cooling fan may break during severe vibration, posing an injury risk if the hood is open.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V623000·2014-10-06

    Spartan Emergency Vehicles Recalled for Transmission Fluid Cooler Failure

    Spartan is recalling 2006-2013 emergency vehicles because a failing transmission fluid cooler may allow engine coolant to mix with transmission fluid, increasing crash risk.

    Product
    SPARTAN — SPARTAN METROSTAR, ADVANTAGE, GLADIATOR, DIAMOND
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V513000·2014-08-20

    Spartan Emergency Vehicles Recalled for Engine Surge Risk

    Spartan is recalling certain 2011-2015 Gladiator and MetroStar emergency vehicles because a software issue may cause engine surges, increasing the risk of personal injury.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V613000·2013-12-06

    Spartan Emergency Vehicles Recalled for Defective Seat Belt Buckles

    Spartan Motors is recalling specific emergency vehicles because seat belt buckles may fail to release, potentially hindering egress during an emergency.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V266000·2013-06-26

    Spartan Gladiator and Metrostar Emergency Vehicles Recalled for Airbag Defect

    Spartan Motors is recalling 2013 Gladiator and Metrostar emergency vehicles because electrical signal fluctuations may cause airbags or seat belt pretensioners to deploy inadvertently.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V579000·2012-12-10

    Spartan Emergency Chassis Recalled for Wiper Motor Shaft Defect

    Spartan Chassis is recalling 2012-2013 emergency rescue chassis cabs because wiper motor and arm shafts have different sized splines, which may cause windshield wipers to become inoperative.

    Product
    SPARTAN — SPARTAN METROSTAR, GLADIATOR, FORCE, METROSTAR-X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V279000·2012-06-19

    Spartan Gladiator Emergency Chassis Recalled for Fan Clutch Separation Risk

    Spartan Chassis is recalling 2010-2012 Gladiator emergency rescue chassis due to a defect that may cause the cooling fan assembly to separate, posing a risk of personal injury.

    Product
    SPARTAN — SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V321000·2011-06-13

    Spartan Fire Apparatus Recalled for Side Air Bag Warning Light Defect

    Spartan is recalling certain 2010-2011 Gladiator and Metrostar fire apparatus chassis because the side air bag warning light may not function, potentially leaving operators unaware of system faults.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V240000·2011-04-14

    Spartan Fire Apparatus Recall for Instrument Cluster Display Defects

    Spartan Chassis is recalling 2010-2011 Metrostar, Furion, and Gladiator fire apparatus chassis due to instrument cluster tell-tale lights that may not illuminate or may flicker.

    Product
    SPARTAN — SPARTAN METROSTAR, FURION, GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all Spartan models