The Recall Desk

Vehicle

Jeep Grand Cherokee · 2021

12 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–12 of 12

  • Severity pendingNHTSA·24V132000·2024-02-22

    Jeep Grand Cherokee upper control arm ball joints may separate

    Chrysler is recalling certain 2021-2023 Jeep Grand Cherokee L and 2022-2023 Grand Cherokee vehicles because the upper control arm ball joint and steering knuckle may separate. 338,238 units affected.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V413000·2023-06-08

    Jeep Grand Cherokee Models Recalled for Detaching Rear Coil Springs

    Chrysler is recalling certain 2022-2023 Jeep Grand Cherokee and 2021-2023 Jeep Grand Cherokee L vehicles. Rear coil springs may detach while driving, creating a crash risk; dealers will repair them free.

    Product
    JEEP — JEEP GRAND CHEROKEE 4XE, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V284000·2022-04-28

    2021 Jeep Grand Cherokee Recalled for Sticking EGR Valve

    Chrysler is recalling 2021 Jeep Grand Cherokee and Dodge Durango vehicles due to EGR valve defects that may cause loss of drive power and increase crash risk. Dealers will provide free replacement.

    Product
    JEEP — JEEP, DODGE GRAND CHEROKEE 4XE, DURANGO, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V873000·2021-11-10

    Jeep Wagoneer and Grand Cherokee Airbag Control Software Defect

    The Occupant Restraint Controller software in certain 2021-2022 Jeep models may be faulty, allowing airbags to disable without warning. This increases crash injury risk.

    Product
    JEEP — JEEP WAGONEER, GRAND CHEROKEE, GRAND WAGONEER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V436000·2024-06-13

    Radio software may disable rearview camera in multiple Chrysler vehicle models

    Certain 2021-2023 Chrysler, Jeep, Ram, and Dodge vehicles have defective radio software that may prevent the rearview camera from displaying, reducing driver visibility when backing up.

    Product
    JEEP — JEEP, CHRYSLER, RAM GRAND CHEROKEE, VOYAGER, GRAND WAGONEER, COMPASS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V577000·2023-08-14

    Jeep Grand Cherokee and Wagoneer Recalled for Rearview Display Failure

    Chrysler is recalling certain Jeep Grand Cherokee and Wagoneer models (2021–2024) due to a software issue that may prevent the rearview display from showing when backing up. This violates federal rear-visibility standards.

    Product
    JEEP — JEEP GRAND CHEROKEE, WAGONEER, GRAND WAGONEER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V352000·2023-05-18

    Jeep Grand Cherokee Steering Column Intermediate Shaft Defect Recall

    Certain 2021–2023 Jeep Grand Cherokee models have an incorrectly assembled steering column intermediate shaft that may disconnect and cause loss of steering control, increasing crash risk. Chrysler is offering free inspection and replacement.

    Product
    JEEP — JEEP GRAND CHEROKEE, GRAND CHEROKEE 4XE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V544000·2022-07-28

    2021-2022 Jeep Grand Cherokee Tail Light Side Marker Assembly Replacement

    Chrysler is recalling certain 2022 Jeep Grand Cherokee and 2021-2022 Jeep Grand Cherokee L vehicles due to damaged tail light side marker assemblies that may not illuminate, reducing visibility and increasing crash risk.

    Product
    JEEP — JEEP GRAND CHEROKEE 4XE, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V180000·2022-03-24

    2021-2022 Jeep Grand Cherokee L seat tether anchorage defect

    Certain 2021-2022 Jeep Grand Cherokee L vehicles may have a missing weld in the child seat tether anchorage system. This could allow the tether to separate during a crash, increasing the risk of child injury.

    Product
    JEEP — JEEP GRAND CHEROKEE, GRAND CHEROKEE 4XE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V950000·2021-12-09

    2021 Jeep Grand Cherokee L Inoperable Headlight Software Defect Recall

    Certain 2021 Jeep Grand Cherokee L vehicles may have inoperable headlights due to a smart lighting module software defect. This reduces visibility and increases the risk of crashes.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V797000·2021-10-14

    2021 Jeep Grand Cherokee High Beam Headlights May Not Activate

    In certain 2021 Jeep Grand Cherokee L vehicles, the high beam headlights will not activate when the lighting switch is in auto position unless the switch is first changed to on. This defect reduces visibility and increases crash risk.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V729000·2021-09-21

    2021 Jeep Grand Cherokee Rearview Camera Display Software Defect

    A software error in the radio system of certain 2021 Jeep Grand Cherokee L vehicles may prevent the rearview camera from displaying, reducing rear visibility and increasing crash risk.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide

NHTSA crash-test safety rating

Federal 5-Star Safety Rating from crash testing. This is a separate government program from the recall(s) above — a high star rating says nothing about whether a specific recall has been fixed, and a recall says nothing about crash-test performance.

  • 20215/5

    2 trims tested for 2021; overall ratings can differ by trim.

    View on NHTSA.gov

Source: NHTSA New Car Assessment Program (NCAP), a federal crash-test program — not a recall record.

Wider context for this vehicle

Beyond the official recalls above. These are third-party figures derived from NHTSA complaint data — useful signal, but not part of our verified recall record.

Federal investigations — 2 open

  • RQ25005 Recall Query · open · suspension:rear:springs:coil springs
  • PE25014 Preliminary Evaluation · open · electrical system: instrument cluster/panel
  • PE24024 Preliminary Evaluation · steering:hydraulic power assist:pump
  • PE15021 Preliminary Evaluation · forward collision avoidance: adaptive cruise control
  • PE14017 Preliminary Evaluation · electrical system:ignition
  • PE12020 Preliminary Evaluation · steering

Complaint clusters with no matching recall

  • 2014 · powertrain — 452 complaints, median 33,800 mi
    Includes 2 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2005 · body — 384 complaints, median 74,320 mi
  • 2015 · powertrain — 348 complaints, median 14,677 mi
    Includes 2 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2005 · powertrain — 239 complaints, median 78,343 mi
    Includes 8 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2007 · powertrain — 180 complaints, median 60,000 mi
    Includes 1 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.

Technical service bulletins

1,545 manufacturer service bulletins across 22 model years. A TSB is repair guidance to dealers, not a safety recall.

Third-party reliability score

  • 2026: 4.4/5
  • 2025: 3.6/5 · 80 complaints · most complained-of: electrical
  • 2024: 2.1/5 · 249 complaints · most complained-of: electrical
  • 2023: 1.5/5 · 402 complaints · most complained-of: electrical
  • 2022: 2.3/5 · 374 complaints · most complained-of: electrical

This is ProblemsByVin’s own published heuristic (1 worst – 5 best), not an official rating and unrelated to our severity scale.

Data on this panel comes from ProblemsByVin, derived from US NHTSA owner complaints and recalls, and licensed CC BY 4.0. It is not published by a federal agency and is not part of our verified recall record.

← Back to all Jeep models