The Recall Desk

Vehicle

Jeep Grand Cherokee · 2012

11 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–11 of 11

  • Severity pendingNHTSA·17V435000·2017-07-10

    Chrysler Recalls 2011-2014 Vehicles for Alternator Failure Risk

    Chrysler is recalling specific 2011-2014 Dodge, Chrysler, and Jeep vehicles because the alternator may fail, causing the vehicle to stall or catch fire.

    Product
    DODGE — DODGE, CHRYSLER, JEEP DURANGO, 300, CHARGER, CHALLENGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V634000·2014-10-08

    Chrysler Group Recalls Vehicles Due to Alternator Failure Risk

    Chrysler Group is recalling specific 2011-2014 models because the alternator may fail, causing the vehicle to stall without warning and increasing crash risk.

    Product
    CHRYSLER — CHRYSLER, DODGE, JEEP 300, CHALLENGER, DURANGO, CHARGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V487000·2011-09-29

    Chrysler Recalls 2012 Vehicles Due to Engine Bearing Failure Risk

    Chrysler is recalling 2012 Chrysler, Dodge, and Jeep vehicles equipped with 3.6L engines because debris may cause connecting rod bearing failure, potentially leading to engine seizure and increased crash risk.

    Product
    DODGE — DODGE, CHRYSLER, JEEP JOURNEY, TOWN AND COUNTRY, 200, CHARGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V115000·2015-02-27

    Chrysler Recalls 2012-2013 Jeep Grand Cherokee and Dodge Durango for Stalling Risk

    Chrysler is recalling 2012-2013 Jeep Grand Cherokee and Dodge Durango vehicles because a fuel pump relay may fail, causing the vehicle to stall without warning and increasing crash risk.

    Product
    DODGE — DODGE, JEEP DURANGO, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide

NHTSA crash-test safety rating

Federal 5-Star Safety Rating from crash testing. This is a separate government program from the recall(s) above — a high star rating says nothing about whether a specific recall has been fixed, and a recall says nothing about crash-test performance.

  • 20124/5

    2 trims tested for 2012; overall ratings can differ by trim.

    View on NHTSA.gov

Source: NHTSA New Car Assessment Program (NCAP), a federal crash-test program — not a recall record.

Wider context for this vehicle

Beyond the official recalls above. These are third-party figures derived from NHTSA complaint data — useful signal, but not part of our verified recall record.

Federal investigations — 2 open

  • RQ25005 Recall Query · open · suspension:rear:springs:coil springs
  • PE25014 Preliminary Evaluation · open · electrical system: instrument cluster/panel
  • PE24024 Preliminary Evaluation · steering:hydraulic power assist:pump
  • PE15021 Preliminary Evaluation · forward collision avoidance: adaptive cruise control
  • PE14017 Preliminary Evaluation · electrical system:ignition
  • PE12020 Preliminary Evaluation · steering

Complaint clusters with no matching recall

  • 2014 · powertrain — 452 complaints, median 33,800 mi
    Includes 2 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2005 · body — 384 complaints, median 74,320 mi
  • 2015 · powertrain — 348 complaints, median 14,677 mi
    Includes 2 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2005 · powertrain — 239 complaints, median 78,343 mi
    Includes 8 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2007 · powertrain — 180 complaints, median 60,000 mi
    Includes 1 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.

Technical service bulletins

1,545 manufacturer service bulletins across 22 model years. A TSB is repair guidance to dealers, not a safety recall.

Third-party reliability score

  • 2026: 4.4/5
  • 2025: 3.6/5 · 80 complaints · most complained-of: electrical
  • 2024: 2.1/5 · 249 complaints · most complained-of: electrical
  • 2023: 1.5/5 · 402 complaints · most complained-of: electrical
  • 2022: 2.3/5 · 374 complaints · most complained-of: electrical

This is ProblemsByVin’s own published heuristic (1 worst – 5 best), not an official rating and unrelated to our severity scale.

Data on this panel comes from ProblemsByVin, derived from US NHTSA owner complaints and recalls, and licensed CC BY 4.0. It is not published by a federal agency and is not part of our verified recall record.

← Back to all Jeep models