  • Severity pendingNHTSA·23V411000·2023-06-08

    Chrysler Recalls Jeep and Ram Vehicles for Engine Stall Risk

    Chrysler is recalling 2014-2020 Jeep Grand Cherokee and 2014-2019 Ram 1500 vehicles with 3.0L Diesel engines because a sensor defect may cause the engine to stall, increasing crash risk.

    Product
    JEEP — JEEP, RAM GRAND CHEROKEE, 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V406000·2022-06-09

    Chrysler Recalls 2014-2020 Jeep and Ram 1500 Diesel Vehicles

    Chrysler is recalling 2014-2020 Jeep Grand Cherokee and 2014-2019 Ram 1500 diesel vehicles because a fuel pump failure may cause fuel starvation and loss of drive power.

    Product
    RAM — RAM, JEEP 1500, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V699000·2020-11-12

    Jeep Grand Cherokee Recalled for EGR Cooler Fire Risk

    Chrysler is recalling 2014-2019 Jeep Grand Cherokee vehicles with 3.0L EcoDiesel engines because a cracked EGR cooler may cause an intake manifold fire.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V332000·2018-05-17

    Chrysler Recalls Vehicles for Cruise Control Disengagement Defect

    Chrysler is recalling over 4.8 million vehicles because a wiring short may prevent the cruise control system from disengaging, increasing crash risk.

    Product
    JEEP — JEEP, RAM, CHRYSLER WRANGLER, CHEROKEE, GRAND CHEROKEE, 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V741000·2017-11-21

    Chrysler Recalls 2014 Models for Alternator Failure Risk

    Chrysler is recalling 17,116 2014 Dodge, Jeep, and Chrysler vehicles because the alternator may fail, causing the vehicle to stall without warning.

    Product
    JEEP — JEEP, CHRYSLER, DODGE GRAND CHEROKEE, 300, CHALLENGER, CHARGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V435000·2017-07-10

    Chrysler Recalls 2011-2014 Vehicles for Alternator Failure Risk

    Chrysler is recalling specific 2011-2014 Dodge, Chrysler, and Jeep vehicles because the alternator may fail, causing the vehicle to stall or catch fire.

    Product
    DODGE — DODGE, CHRYSLER, JEEP DURANGO, 300, CHARGER, CHALLENGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V240000·2016-04-25

    Chrysler Recalls 2012-2015 Vehicles for Transmission Warning Defect

    Chrysler is recalling specific 2012-2015 Dodge, Chrysler, and Jeep vehicles because they may fail to warn drivers when exiting while in gear, posing a rollaway risk.

    Product
    DODGE — DODGE, CHRYSLER, JEEP CHARGER, 300, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V643000·2014-10-14

    Chrysler Recalls 2014 Dodge Durango and Jeep Grand Cherokee for Airbag Fault

    Chrysler is recalling 2014 Dodge Durango and Jeep Grand Cherokee vehicles because a module fault may disable airbags and seat belt pretensioners, increasing injury risk in crashes.

    Product
    DODGE — DODGE, JEEP DURANGO, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V634000·2014-10-08

    Chrysler Group Recalls Vehicles Due to Alternator Failure Risk

    Chrysler Group is recalling specific 2011-2014 models because the alternator may fail, causing the vehicle to stall without warning and increasing crash risk.

    Product
    CHRYSLER — CHRYSLER, DODGE, JEEP 300, CHALLENGER, DURANGO, CHARGER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V293000·2014-06-04

    Chrysler Recalls 2014 Vehicles for Adaptive Cruise Control Acceleration Defect

    Chrysler is recalling 2014 Dodge Durango, Jeep Cherokee, and Grand Cherokee vehicles because the adaptive cruise control system may cause unintended continued acceleration after the driver releases the pedal.

    Product
    DODGE — DODGE, JEEP DURANGO, CHEROKEE, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V475000·2020-08-13

    Chrysler Recalls Ram 1500 and Jeep Grand Cherokee for Engine Stall Risk

    Chrysler is recalling 2014-2018 Ram 1500 and 2014-2016 Jeep Grand Cherokee diesel vehicles because a sensor defect may cause the engine to stall, increasing crash risk.

    Product
    RAM — RAM, JEEP 1500, GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V461000·2015-07-23

    Chrysler Recalls 2013-2015 Vehicles for Radio Software Vulnerability

    Chrysler is recalling specific 2013-2015 Ram, Jeep, Dodge, and Chrysler vehicles because radio software vulnerabilities allow unauthorized remote access to vehicle control systems, increasing crash risk.

    Product
    RAM — RAM, JEEP, DODGE 5500, 1500, CHEROKEE, VIPER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V289000·2013-07-02

    Chrysler Recalls 2014 Jeep Grand Cherokee for Headlamp Electrical Defect

    Chrysler is recalling 2014 Jeep Grand Cherokee vehicles because electrical spikes may cause parking lamps to turn off, reducing visibility and increasing crash risk.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide

NHTSA crash-test safety rating

Federal 5-Star Safety Rating from crash testing. This is a separate government program from the recall(s) above — a high star rating says nothing about whether a specific recall has been fixed, and a recall says nothing about crash-test performance.

  • 20145/5

    4 trims tested for 2014; overall ratings can differ by trim.

    View on NHTSA.gov

Source: NHTSA New Car Assessment Program (NCAP), a federal crash-test program — not a recall record.

Wider context for this vehicle

Beyond the official recalls above. These are third-party figures derived from NHTSA complaint data — useful signal, but not part of our verified recall record.

Federal investigations — 2 open

  • RQ25005 Recall Query · open · suspension:rear:springs:coil springs
  • PE25014 Preliminary Evaluation · open · electrical system: instrument cluster/panel
  • PE24024 Preliminary Evaluation · steering:hydraulic power assist:pump
  • PE15021 Preliminary Evaluation · forward collision avoidance: adaptive cruise control
  • PE14017 Preliminary Evaluation · electrical system:ignition
  • PE12020 Preliminary Evaluation · steering

Complaint clusters with no matching recall

  • 2014 · powertrain — 452 complaints, median 33,800 mi
    Includes 2 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2005 · body — 384 complaints, median 74,320 mi
  • 2015 · powertrain — 348 complaints, median 14,677 mi
    Includes 2 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2005 · powertrain — 239 complaints, median 78,343 mi
    Includes 8 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.
  • 2007 · powertrain — 180 complaints, median 60,000 mi
    Includes 1 alleging a fire. Unverified owner allegations from complaint filings — not confirmed by any agency.

Technical service bulletins

1,545 manufacturer service bulletins across 22 model years. A TSB is repair guidance to dealers, not a safety recall.

Third-party reliability score

  • 2026: 4.4/5
  • 2025: 3.6/5 · 80 complaints · most complained-of: electrical
  • 2024: 2.1/5 · 249 complaints · most complained-of: electrical
  • 2023: 1.5/5 · 402 complaints · most complained-of: electrical
  • 2022: 2.3/5 · 374 complaints · most complained-of: electrical

This is ProblemsByVin’s own published heuristic (1 worst – 5 best), not an official rating and unrelated to our severity scale.

Data on this panel comes from ProblemsByVin, derived from US NHTSA owner complaints and recalls, and licensed CC BY 4.0. It is not published by a federal agency and is not part of our verified recall record.

← Back to all Jeep models