  • Severity pendingNHTSA·21V366000·2021-05-19

    International and IC Bus commercial vehicles recalled for fuel rail assembly defect

    Navistar is recalling certain 2018-2021 International and IC Bus commercial vehicles due to a fuel rail assembly defect. A sealing washer may not seat correctly, allowing fuel leaks that could ignite.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS DURASTAR, WORKSTAR, HV, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V219000·2020-04-17

    International DuraStar and WorkStar Fuel Heater Fire and Engine Stall Recall

    Navistar is recalling 2017-2020 International DuraStar and WorkStar models, plus IC bus vehicles with Cummins B6.7 engines. The electric fuel heater may overheat and catch fire or cause engine stalling.

    Product
    IC BUS — IC BUS, INTERNATIONAL TC, CE, MV, DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V216000·2019-03-20

    Navistar Recalls 23,122 Vehicles for Fuel Heater Fire Risk

    Navistar is recalling 23,122 vehicles because an electric fuel heater may overheat, melt plastic, and cause a fire or engine stall.

    Product
    IC BUS — IC BUS, INTERNATIONAL CE, TC, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V597000·2018-09-07

    Navistar Recalls 2019 International and IC Bus Vehicles for Brake Defect

    Navistar is recalling 2,089 2019 International and IC Bus vehicles because a brake chamber defect may cause air leaks, increasing stopping distance and crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS LT, HX, WORKSTAR, DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V575000·2017-09-20

    2016 International Commercial Vehicles Recalled for Steering Tie Rod Defect

    Navistar is recalling 2016 International and IC Bus vehicles because a steering axle nut may not be properly torqued, risking loss of steering.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS DURASTAR, LONESTAR, PROSTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V776000·2015-11-20

    Navistar Recalls 2013-2014 International Trucks for Accelerator Pedal Defect

    Navistar is recalling 2013-2014 International trucks because a faulty accelerator pedal sensor can cause high engine idle, increasing crash risk on downgrades.

    Product
    INTERNATIONAL — INTERNATIONAL TRANSTAR, DURASTAR, WORKSTAR, LONESTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V241000·2015-04-22

    Navistar Recalls 2011-2015 Commercial Vehicles for HVAC Fire Risk

    Navistar is recalling 82,736 commercial vehicles because an electrical issue in the HVAC system could cause a fire.

    Product
    IC BUS — IC BUS, INTERNATIONAL AC, TRANSTAR, HC, ICSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V165000·2015-03-23

    Navistar Recalls 2015-2016 International Trucks Due to Brake Fire Risk

    Navistar is recalling 2015-2016 International and IC Bus vehicles because defective brake actuators may cause dragging, overheating, and wheel end fires.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS TRANSTAR, CE, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V201000·2014-04-17

    Navistar Recalls 2013-2015 International Trucks Due to Brake Caliper Bolt Defect

    Navistar is recalling certain 2013-2015 International DuraStar, WorkStar, ProStar, and TranStar trucks because brake caliper bolts may be missing or improperly torqued, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, WORKSTAR, PROSTAR, TRANSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V509000·2012-10-18

    Navistar Recalls 2012 International Trucks Due to Passenger Seat Defect

    Navistar is recalling 2012 International DuraStar and Workstar trucks because the front passenger seat may separate from its mounting rails, increasing injury risk in a crash.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V465000·2012-09-20

    Navistar Recalls International Trucks Due to Parking Brake Air Leak

    Navistar is recalling specific International trucks because an air leak in the parking brake chamber may prevent the brake from fully releasing, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL PROSTAR, DURASTAR, WORKSTAR, 8600
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V403000·2012-08-14

    Navistar Recalls 2011-2013 International Trucks for Brake Caliper Bolt Defect

    Navistar is recalling certain 2011-2013 International trucks because brake caliper bolts may be loose, increasing stopping distance or causing a pull during braking.

    Product
    INTERNATIONAL — INTERNATIONAL WORKSTAR, TRANSTAR, PROSTAR, DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V283000·2012-06-20

    Navistar Recalls 2013 International Durastar Trucks for Windshield Defect

    Navistar is recalling 1,298 2013 International Durastar trucks because windshield and backlight glass may separate from the cab, increasing the risk of injury or death.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V052000·2012-02-13

    Navistar Recalls International Trucks and Buses for Brake Valve Defect

    Navistar is recalling certain 2011-2013 International trucks and IC Buses because Bendix relay valves may leak in cold weather, causing continuous brake application and fire risk.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS 9200, CE-C, 9800, PAYSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V167000·2011-03-14

    Navistar Recalls International Durastar and Workstar Trucks for Brake Defect

    Navistar is recalling certain 2011-2012 International Durastar and Workstar trucks because a defective brake component could break, reducing braking capacity and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V397000·2023-06-02

    Commercial Buses and Trucks Recalled for Brake Pressure Switch Fire Risk

    Navistar is recalling certain IC BUS and International commercial buses and trucks due to a brake pressure switch defect that may cause electrical short and fire risk. Owners should park vehicles outside until repairs are completed.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS MV, DURASTAR, 1300FBC, TC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V248000·2023-04-06

    Navistar Recalls International Buses Due to HVAC Wiring Fire Risk

    Navistar is recalling 2016-2020 International and IC Bus models because an HVAC wiring terminal may overheat, increasing the risk of a fire.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS TRANSTAR, DURASTAR, PROSTAR, LONESTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V810000·2020-12-23

    International DuraStar and WorkStar Engine Control Software Defect Recall

    Navistar recalls 17,213 2014-2021 International commercial trucks with an engine control defect. The software flaw can cause unexpected vehicle movement when parked with the PTO engaged, risking crashes and injury.

    Product
    INTERNATIONAL — INTERNATIONAL MV, DURASTAR, WORKSTAR, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V841000·2019-11-21

    Navistar Recalls International Trucks Due to Parking Brake Failure Risk

    Navistar is recalling specific International trucks because engaging the PTO switch can override the parking brake, causing unintended movement.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, WORKSTAR, HV, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·19V239000·2019-03-26

    Custom Fab & Body Recalls Emergency Vehicles with Faulty Brake Lights

    Custom Fab & Body is recalling specific 2017-2018 emergency vehicles because Whelen brake lights may illuminate without the brake pedal being pressed, potentially confusing other drivers.

    Product
    KENWORTH — KENWORTH, FORD, INTERNATIONAL T370, F-650 SD, WORKSTAR, DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V792000·2017-12-11

    Navistar Recalls International Trucks Due to Fire Extinguisher Defect

    Navistar is recalling specific International trucks because the installed fire extinguishers may clog, require excessive force to activate, or detach, potentially causing injury or failing to suppress a fire.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, 9100I, 4900, 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V631000·2015-10-08

    Navistar Recalls 2016 International Trucks Due to Engine Stalling Risk

    Navistar is recalling specific 2016 International trucks because the engine control module may short circuit, causing the engine to stall without warning and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, LONESTAR, PAYSTAR, PROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V572000·2014-09-19

    Navistar Recalls 2015 International Durastar and IC Bus CE Vehicles

    Navistar is recalling 2015 International Durastar and IC Bus CE vehicles because a fuel filter defect may cause the engine to stall without warning, increasing crash risk.

    Product
    IC BUS — IC BUS, INTERNATIONAL CE, DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V063000·2014-02-19

    Navistar Recalls 2011-2014 International Trucks for Emergency Vehicle Shutdown Risk

    Navistar is recalling specific International DuraStar and TerraStar trucks intended for emergency use because a software error may cause the engine to shut down during rescue operations.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, TERRASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V146000·2013-04-17

    Navistar Recalls International Trucks Due to Sun Shade Separation Risk

    Navistar is recalling certain 2011-2013 International commercial trucks because sun shades may separate from the roof, potentially distracting the driver and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LONESTAR, PROSTAR, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V020000·2013-01-17

    Navistar Recalls 2011-2013 Vehicles for Engine Shutdown Risk

    Navistar is recalling 7,657 vehicles from 2011-2013 because a wire may break, causing the engine to shut down unexpectedly while driving.

    Product
    IC BUS — IC BUS, INTERNATIONAL, HOLIDAY RAMBLER ICSB, 1300FBC, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V252000·2011-04-19

    Navistar Recalls 2011-2012 International Trucks for Brake System Defect

    Navistar is recalling certain 2011-2012 International commercial trucks because the trailer ABS fault indicator lamp may fail to illuminate, potentially increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL PAYSTAR, LONESTAR, PROSTAR, DURASTAR