389 recalls in our database name BMW of North America, LLC as the manufacturing or recalling firm.

What the numbers show

Total
389
Critical
4
Severe
202
Most recent
2026-10-21

Of the 389 recalls from BMW of North America, LLC we have scored against our rubric, 4 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 202 (52%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

76–100 of 389

  • HighNHTSA·23V884000·2023-12-22

    BMW Recalls 2021-2024 R 18 Motorcycles for Headlight Defect

    BMW is recalling 2,369 motorcycles because headlight attachment points may break, causing insufficient illumination and increasing crash risk.

    Product
    BMW — BMW R 18 B, R 18 TRANSCONTINENTAL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V821000·2023-12-06

    2023 BMW models recalled for transmission control unit weld defect

    BMW is recalling certain 2023 models with a transmission control unit weld defect that may allow oil leakage, risking sudden power loss and increased crash risk.

    Product
    BMW — BMW, TOYOTA Z4, X3, 8 SERIES, 3 SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V797000·2023-11-24

    BMW Recalls 2014-2015 X3, X4, and X5 Models for Airbag Defect

    BMW is recalling specific 2014-2015 X3, X4, and X5 vehicles because the driver's airbag inflator may explode during deployment, posing a risk of serious injury or death.

    Product
    BMW — BMW X4, X3, X5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V770000·2023-11-16

    2024 BMW X3 and Related Models: Loose Steering Gear Recall

    BMW is recalling certain 2024 BMW X3 and related models due to steering gear that may not have been properly tightened, which can loosen and cause loss of vehicle control. Dealers will replace the steering gear free of charge.

    Product
    BMW — BMW 330I, X4, X3, 230I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V707000·2023-10-20

    BMW Recalls 157,796 Vehicles for Potential Engine Stall Risk

    BMW is recalling 157,796 vehicles from 2010-2012 because aluminum bolts securing the VANOS unit may loosen or break, potentially causing an engine stall and increasing crash risk.

    Product
    BMW — BMW X5, Z4, 3 SERIES, 1 SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V700000·2023-10-18

    BMW 750e and multiple 2023-2024 models recalled for steering wheel sensor defect

    BMW is recalling certain 2023-2024 models including the 750e due to a faulty ground connection in the steering wheel electrical system. The defect may render the hands-on detection system inoperative, preventing the emergency stopping assistant from engaging and increasing crash risk.

    Product
    BMW — BMW 740I, I5, I7, I7 M70
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V644000·2023-09-20

    BMW Recalls 2023 740i, 760i, and i7 Models for Wiper Failure

    BMW is recalling 2023 740i, 760i, and i7 vehicles because windshield wipers may fail in certain weather, reducing visibility and increasing crash risk.

    Product
    BMW — BMW 760I, I7, 740I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V622000·2023-09-07

    2023-2024 BMW Models Recall: Front Passenger Knee Air Bag Deployment Failure

    BMW is recalling certain 2023 BMW XM and 2024 BMW X5, X6, X7, and Alpina XB7 vehicles because the front passenger knee air bag may not deploy as intended, increasing injury risk in a crash.

    Product
    BMW — BMW X6, XM, X5, X7
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V584000·2023-08-16

    BMW vehicles with defective seat belt warning software recalled

    BMW is recalling 2019-2022 330i, M340i, and other models due to receiver audio module software that may fail to generate proper seat belt warnings, increasing crash injury risk.

    Product
    BMW — BMW M340I, 228I, M440I, 330I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V479000·2023-07-12

    BMW Recalls 2023 Models for Dashboard Control Malfunction

    BMW is recalling 2023 740i, 760i, and i7 vehicles because the dashboard Interaction Bar may fail to activate defrosting or hazard lights.

    Product
    BMW — BMW 760I, I7, 740I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V471000·2023-07-10

    2023 BMW XM and 2024 X5-X7 vehicles recalled for knee air bag defect

    BMW of North America is recalling 2023 XM and certain 2024 X5, X6, and X7 vehicles because the knee air bag may not have been manufactured correctly and could fail to deploy during a crash. Dealers will replace the air bag free of charge.

    Product
    BMW — BMW X5, X6, XM, X7
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V449000·2023-06-28

    2022-2023 BMW I4 Recalled for High Voltage Battery Charging Unit Failure

    BMW recalls certain 2022-2023 I4, iX, and i760 models due to a defective high voltage battery charging unit that may not have been properly assembled, potentially causing engine stall while driving.

    Product
    BMW — BMW IX, I4, 760I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V414000·2023-06-08

    BMW Recalls 2023 740i, 760i, and i7 for Seat Welding Defect

    BMW is recalling 2023 740i, 760i, and i7 vehicles because front seat length adjustment systems may not be welded properly, increasing injury risk in a crash.

    Product
    BMW — BMW 760I, 740I, I7
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V337000·2023-05-11

    BMW Recalls 2007-2014 MINI Cooper Models for Fire Risk

    BMW is recalling 2007-2014 MINI Cooper models because a short-circuit in the driver's footwell may cause a fire. Owners should contact dealers for inspection and repair.

    Product
    MINI — MINI COOPER CLUBMAN, COOPER, COOPER S, JCW
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V295000·2023-04-26

    BMW iX and i4 vehicles recalled for battery monitoring circuit defect

    BMW is recalling certain 2022-2024 iX xDrive50 and 2023 i4 models due to improperly secured electrical connections in the battery monitoring circuit, which can cause engine stall and increase crash risk.

    Product
    BMW — BMW IX, I4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V294000·2023-04-26

    2023 BMW X7 and XM Recalled for Loose Exhaust-to-Catalytic Converter Fasteners

    BMW is recalling 2023 X7 and XM models due to improperly tightened fasteners connecting the exhaust system to the catalytic converter, which could increase fire risk. Dealers will replace the gasket and tighten fasteners at no charge.

    Product
    BMW — BMW X7, XM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V260000·2023-04-12

    2023 BMW X1 recalled for pinched rear seat belts

    BMW is recalling 2023 X1 models because rear seat belts may have been pinched during assembly, potentially preventing proper function in a crash. Dealers will inspect and adjust the trim panels at no charge.

    Product
    BMW — BMW X1
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V253000·2023-04-06

    2023 BMW X5 Head Restraints May Fail in Crash

    BMW is recalling approximately 235 certain 2023 X5 vehicles with defective second-row head restraints that may not properly restrain occupants during a crash, violating federal safety standards.

    Product
    BMW — BMW X5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V211000·2023-03-29

    BMW seats may not restrain occupants properly in crash

    BMW is recalling certain 2019–2021 3-series and X3/X4 models because the seat frame may not have been welded properly to the seat rails, risking occupant injury in a crash.

    Product
    BMW — BMW X3, M340I, 330I, X4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V123000·2023-02-24

    2023 BMW S 1000 RR Motorcycles Recalled for Hand Brake Defect

    BMW of North America is recalling certain 2023 S 1000 RR motorcycles due to a hand brake lever defect that may reduce brake performance. Approximately 394 units are affected.

    Product
    BMW — BMW S 1000 RR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V118000·2023-02-23

    2022-2023 BMW M3 Door Locking Software Defect Recall

    BMW is recalling certain 2022-2023 models due to a door locking software defect. Faulty ECU programming may prevent doors from locking while driving, increasing crash injury risk.

    Product
    BMW — BMW I4, M440I, M340I, 430I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V099000·2023-02-17

    2023 BMW vehicles recalled for unintended power window and sunroof closure

    BMW is recalling 2023 and some 2022 model-year vehicles for a software defect allowing power windows and sunroofs to close without the digital key present, posing a risk of injury to occupants.

    Product
    BMW — BMW Z4, M850I, 840I, 230I
    Category
    Vehicle
    Distribution
    Distributed nationwide