The Recall Desk

Hazard

Loss Of Drive Power recalls

156 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
156
Critical
0
Severe
95
Most recent
2026-08-25

Of the 156 loss of drive power recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 95 (61%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all loss of drive power recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

101–125 of 156

  • HighNHTSA·23V482000·2023-07-12

    Nova Bus LFS Transit Buses Recalled for Driveshaft Separation

    Nova Bus is recalling certain 2019-2023 LFS and LFS Artic transit buses. The transmission yoke may separate, causing driveshaft separation and sudden loss of drive power, increasing the risk of crashes and passenger injury.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V462000·2023-06-30

    Mercedes-Benz Recalls C300 and AMG C43 for Wiring Harness Defect

    Mercedes-Benz is recalling 2022-2023 C300 and 2023 AMG C43 vehicles because an incorrectly sized transmission wiring harness may cause damage and loss of drive power.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG C43, C 300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V445000·2023-06-26

    Mercedes-Benz Fuel Pump May Fail, Causing Loss of Drive Power

    Mercedes-Benz USA is recalling certain 2021–2023 vehicles with faulty fuel pumps that may shutdown and cause loss of drive power. Owners should contact dealers for free replacement.

    Product
    MERCEDES-MAYBACH — MERCEDES-MAYBACH, MERCEDES-BENZ S 680, S 580, S 580 4MATIC, S 500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V405000·2023-06-05

    Mercedes-Benz Recalls EQS and EQE Models for Drivetrain Software Error

    Mercedes-Benz is recalling 8,281 electric vehicles due to a software error that may cause a loss of drive power, increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG EQE, AMG EQS, EQS 580, EQS 450
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V367000·2023-05-25

    2023 Cadillac Lyriq Battery Connection Defect May Cause Loss of Drive Power

    General Motors is recalling certain 2023 Cadillac Lyriq and 2022 GMC Hummer EV vehicles. Connections in the high-voltage battery pack may be out of position or incorrectly welded, potentially causing loss of drive power and increasing crash risk.

    Product
    CADILLAC — CADILLAC, GMC LYRIQ, HUMMER EV PICKUP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V349000·2023-05-17

    Foretravel Recalls 2022-2024 Motorhomes Due to Software Error

    Foretravel is recalling 2022-2024 Realm, FS450, and Realm Presidential motorhomes because a software error may cause loss of drive power or disable safety systems.

    Product
    FORETRAVEL — FORETRAVEL REALM, FS450, REALM PRESIDENTIAL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V322000·2023-05-04

    2023 International MV Trucks: Driveshaft Weld Defect Recall

    Navistar is recalling 49 2023 International MV trucks because the driveshaft tube seam weld may separate or tear, causing sudden loss of drive power and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V303000·2023-04-27

    2022-2023 Jeep Wrangler Plug-In Hybrid Battery Fuse Fastener Defect

    Chrysler is recalling certain 2022-2023 Jeep Wrangler PHEVs due to incorrect fasteners in the high voltage battery pack that can cause excessive heat and potential loss of drive power, increasing crash risk.

    Product
    JEEP — JEEP WRANGLER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V224000·2023-03-30

    2022–2024 Jayco and Entegra motorhomes recalled for software error

    Jayco and Entegra motorhomes (2022–2024 models) may lose drive power or key safety functions due to a vehicle control module software error, increasing crash risk.

    Product
    ENTEGRA — ENTEGRA, JAYCO CORNERSTONE, ASPIRE, REATTA, EMBARK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V199000·2023-03-24

    Ford Explorer driveshaft disconnect and parking brake recall

    Ford is recalling certain 2020-2022 Explorer vehicles due to potential driveshaft disconnection and incomplete parking brake software, which could cause vehicle rollaway and loss of drive power.

    Product
    FORD — FORD EXPLORER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V196000·2023-03-23

    Autocar Recalls Legend and Xpeditor Trucks for Driveline Bearing Issue

    Autocar is recalling 2020-2023 Legend and 2022-2023 Xpeditor trucks because the driveline center support bearing hardware may not be secured, risking driveline detachment.

    Product
    AUTOCAR — AUTOCAR XPEDITOR, LEGEND
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V172000·2023-03-16

    2023 Cadillac XT6 Transmission Defect Recall for Half-Shaft Disengagement

    General Motors is recalling 2023 Cadillac XT6 and related vehicles due to a transmission defect. An incorrectly built sun gear can cause the half-shaft to disengage, risking loss of drive power or vehicle rollaway.

    Product
    CADILLAC — CADILLAC, CHEVROLET, GMC XT5, BLAZER, XT6, TRAVERSE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V153000·2023-03-08

    2023 International MV and HV Vehicles Recalled for Driveshaft Separation Risk

    Navistar is recalling certain 2023 International HV and 2023-2024 International MV vehicles due to incorrectly installed rear axle wedge shims that can cause driveshaft separation and loss of drive power. This increases the risk of a crash.

    Product
    INTERNATIONAL — INTERNATIONAL MV, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V145000·2023-03-03

    Xos Recalls 275 Vehicles Due to Driveshaft Bolt Tightening Defect

    Xos is recalling 275 RM01, SA01, and SV05 vehicles because improperly tightened bolts may allow the driveshaft to separate, increasing crash risk.

    Product
    XOS — XOS RM01, SV05, SA01
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V095000·2023-02-16

    Electra Meccanica Solo G2 and G3 recalled for sudden loss of drive power

    Electra Meccanica is recalling 2019-2023 Solo vehicles due to a defect in the motor controller or battery controller that can cause sudden loss of drive power, increasing crash risk. Owners are being notified and eligible for vehicle repurchase.

    Product
    ELECTRAMECCANICA — ELECTRAMECCANICA SOLO G3, SOLO G2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V062000·2023-02-09

    Spartan Motorhome Chassis Software Error Causes Loss of Drive Power and Visibility

    Shyft Group is recalling 2022–2024 Spartan motorhome chassis due to a software error that may cause loss of drive power or safety functions like headlights and wipers. Owners should contact Shyft Group at 1-800-237-7806 for a free software update.

    Product
    SPARTAN — SPARTAN K2, K3, K4, K1
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V941000·2022-12-16

    Hyundai Recalls 2021 Kona Electric Vehicles Due to EPCU Coolant Leak Risk

    Hyundai is recalling 2021 Kona Electric vehicles because a defective Electric Power Control Unit may leak coolant, potentially causing a loss of drive power and increasing crash risk.

    Product
    HYUNDAI — HYUNDAI KONA ELECTRIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V917000·2022-12-12

    Volvo Bus 9700 Recalled for GPS Installation Defect

    Volvo Bus is recalling 2022 9700 buses because incorrectly installed GPS devices may cause accelerator sensor malfunction and loss of drive power.

    Product
    VOLVO BUS — VOLVO BUS 9700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V899000·2022-12-06

    Kia Recalls 2020 Niro EV Vehicles for EPCU Coolant Leak Risk

    Kia is recalling 2020 Niro EV vehicles because a coolant leak in the Electric Power Control Unit may cause loss of drive power, increasing crash risk.

    Product
    KIA — KIA NIRO EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V876000·2022-11-23

    2023 Thomas Built Buses SAF-T-LINER C2 Recalled for Battery Pack Defect

    Daimler Trucks North America is recalling 2023 Thomas Built Buses SAF-T-LINER C2 JOULEY school buses because an insufficient battery connection may cause sudden loss of drive power.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER C2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V771000·2022-10-13

    GM Recalls 2022-2023 Hummer EV and BrightDrop EV600 for Battery Seal Defect

    General Motors is recalling 2022-2023 Hummer EV Pickups and 2022 BrightDrop EV600s because the high-voltage battery pack may not be sealed, allowing water entry that can cause loss of drive power.

    Product
    GMC — GMC, BRIGHTDROP HUMMER EV PICKUP, EV600
    Category
    Vehicle
    Distribution
    Distributed nationwide