  • Severity pendingNHTSA·18V090000·2018-02-02

    Jaguar Recalls 2018 Models for Fuel Rail Leak Fire Risk

    Jaguar is recalling 2018 XE, XF, E-PACE, F-PACE, and F-TYPE vehicles because fuel rail end caps may leak, increasing the risk of a fire.

    Product
    JAGUAR — JAGUAR XF, E-PACE, F-TYPE, F-PACE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V010000·2018-01-08

    Jaguar Recalls XF Vehicles Due to Air Bag Inflator Explosion Risk

    Jaguar is recalling 2010-2015 XF vehicles because the front passenger air bag inflator may explode during deployment, potentially causing serious injury or death.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V009000·2018-01-08

    Jaguar Recalls 2009-2013 XF Models for Air Bag Inflator Defect

    Jaguar is recalling 2009-2013 XF vehicles because the front passenger air bag inflators may explode during a crash, potentially causing serious injury or death.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V084000·2017-02-09

    Jaguar Recalls 2017 XF Models Due to Fuel Line Fire Risk

    Jaguar is recalling 2017 XF vehicles because a cracked left inner sill panel could cause fuel lines to rupture in a crash, increasing fire risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V373000·2016-05-27

    Jaguar Recalls 2009-2011 XF Models for Air Bag Inflator Rupture Risk

    Jaguar is recalling 2009-2011 XF vehicles in specific states because passenger air bag inflators may rupture during a crash, potentially causing serious injury or death.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V091000·2015-02-18

    Jaguar Recalls 2013 XF Vehicles for Fuel Pump Shutdown Risk

    Jaguar is recalling 2013 XF vehicles because the fuel pump may shut down, causing the vehicle to stall and lose power-assisted braking and steering.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V390000·2014-07-01

    Jaguar Recalls 2013-2014 XF Vehicles for Steering Hose Defect

    Jaguar is recalling 2013-2014 XF vehicles because a steering hose may collapse, reducing power assist and increasing crash risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V291000·2014-06-02

    Jaguar Recalls 2013-2014 XF Models Due to Brake Pipe Wear

    Jaguar is recalling 2013-2014 XF vehicles because the rear brake pipe may wear and leak fluid, increasing crash risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V181000·2014-03-31

    Jaguar Recalls 2013-2014 XF Models Due to Loose Charge Air Cooler Hose Clamp

    Jaguar is recalling 2013-2014 XF 2.0L GTDi vehicles because a loose hose clamp may allow the Charge Air Cooler hose to detach, potentially causing the engine to stall and loss of steering and brake assistance.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V157000·2014-03-31

    Jaguar Recalls 2013-2014 XJ, XF, and XK for Rear Suspension Defect

    Jaguar is recalling 2013-2014 XJ, XF, and XK vehicles because rear toe links can separate, potentially causing loss of vehicle control and increasing crash risk.

    Product
    JAGUAR — JAGUAR XK, XF, XJ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V571000·2012-12-07

    Jaguar Recalls 2013 XF Vehicles Due to Fuel Pump Shutdown Risk

    Jaguar is recalling 2013 XF vehicles because electronic modules may shut down the fuel pump, causing the engine to stall and increasing crash risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V521000·2012-10-26

    Jaguar Recalls 2010-2012 XF Vehicles for Fuel Tank Flange Defect

    Jaguar is recalling 2010-2012 XF vehicles with 5.0L engines because a fuel tank flange may crack, causing fuel leaks and potential fire.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V168000·2011-03-14

    Jaguar Recalls 2010 XF and XK Models for Steering Pipe Corrosion

    Jaguar is recalling 2010 XF and XK vehicles because power steering pipes may corrode, potentially causing fluid leaks, loss of steering assist, or fire.

    Product
    JAGUAR — JAGUAR XF, XK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·10V332000·2010-07-22

    Jaguar Recalls XF and XK Vehicles for Fuel Pump Relay Defect

    Jaguar is recalling 2010-2011 XK and 2010 XF vehicles because a fuel pump relay may fail, causing the engine to cut out and potentially leading to a crash.

    Product
    JAGUAR — JAGUAR XK, XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V524000·2022-07-21

    2022 Jaguar XF, F-Type, F-Pace seat belt pretensioner failure

    Jaguar is recalling 2022 XF, F-Type, and F-Pace vehicles because the driver and front passenger seat belt pretensioners may be damaged, causing improper restraint during a crash.

    Product
    JAGUAR — JAGUAR F-PACE, XF, F-TYPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V667000·2021-08-26

    Jaguar Recalls F-Pace, XF, and F-Type for Seat Belt Retractions

    Jaguar is recalling 2020-2022 F-Pace, XF, and F-Type vehicles because seat belt retractors may deactivate early, preventing child restraints from securing properly.

    Product
    JAGUAR — JAGUAR F-TYPE, F-PACE, XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V081000·2020-02-13

    Jaguar Recalls 2010 XF Vehicles Due to Fuel Leak Fire Risk

    Jaguar is recalling 2010 XF vehicles with 4.2L engines because a cracked fuel tank outlet flange may leak fuel, increasing fire risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V229000·2016-04-20

    Jaguar Recalls XF Vehicles Due to Driver Air Bag Defect

    Jaguar is recalling certain 2009, 2011, 2012, and 2015 XF vehicles because the driver frontal air bag may deploy improperly, increasing injury risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V137000·2016-03-07

    Jaguar Recalls 2013-2015 XF Vehicles for Power Steering Defect

    Jaguar is recalling 2013-2015 XF vehicles because a faulty engine component may cause a loss of power steering assist, increasing crash risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V123000·2014-03-14

    Jaguar Recalls 2013 XJ and XF Vehicles for Missing Certification Labels

    Jaguar is recalling 2013 XJ and XF vehicles because they lack required certification labels specifying weight ratings. This non-compliance could lead to vehicle overloading and increased crash risk.

    Product
    JAGUAR — JAGUAR XJ, XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V341000·2013-08-05

    Jaguar Recalls 2013 XF Models Due to Loose Charge Air Cooler Hose Clamp

    Jaguar is recalling 2013 XF 2.0L GTDi vehicles because a loose hose clamp may allow the Charge Air Cooler hose to detach, potentially causing the engine to stall and increasing crash risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V604000·2011-12-28

    Jaguar Recalls 2012 XF Vehicles for Incorrect Weight Rating Label

    Jaguar is recalling 2012 XF vehicles because an incorrect Gross Vehicle Weight Rating label may lead owners to exceed safe limits, increasing crash risk.

    Product
    JAGUAR — JAGUAR XF
    Category
    Vehicle
    Distribution
    Distributed nationwide

NHTSA crash-test safety rating

Federal 5-Star Safety Rating from crash testing. This is a separate government program from the recall(s) above — a high star rating says nothing about whether a specific recall has been fixed, and a recall says nothing about crash-test performance.

  • 2022Not rated by NHTSA

    2 trims tested for 2022; overall ratings can differ by trim.

    View on NHTSA.gov
  • 2021Not rated by NHTSA

    2 trims tested for 2021; overall ratings can differ by trim.

    View on NHTSA.gov
  • 2018Not rated by NHTSA

    2 trims tested for 2018; overall ratings can differ by trim.

    View on NHTSA.gov
  • 2017Not rated by NHTSA

    2 trims tested for 2017; overall ratings can differ by trim.

    View on NHTSA.gov

Source: NHTSA New Car Assessment Program (NCAP), a federal crash-test program — not a recall record.

Wider context for this vehicle

Beyond the official recalls above. These are third-party figures derived from NHTSA complaint data — useful signal, but not part of our verified recall record.

Federal investigations

  • RQ19004 Recall Query · fuel system, gasoline:storage:tank assembly

Technical service bulletins

1,162 manufacturer service bulletins across 16 model years. A TSB is repair guidance to dealers, not a safety recall.

Third-party reliability score

  • 2024: 4.8/5 · 1 complaints
  • 2023: 4.8/5 · 1 complaints
  • 2022: 4.6/5 · 2 complaints
  • 2021: 4.9/5
  • 2018: 4.4/5 · 2 complaints

This is ProblemsByVin’s own published heuristic (1 worst – 5 best), not an official rating and unrelated to our severity scale.

Data on this panel comes from ProblemsByVin, derived from US NHTSA owner complaints and recalls, and licensed CC BY 4.0. It is not published by a federal agency and is not part of our verified recall record.

← Back to all Jaguar models