The Recall Desk

Manufacturer

Thor Motor Coach

136 recalls in our database name Thor Motor Coach as the manufacturing or recalling firm.

What the numbers show

Total
136
Critical
0
Severe
58
Most recent
2025-11-17

Of the 136 recalls from Thor Motor Coach we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 58 (43%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

26–50 of 136

  • HighNHTSA·21V756000·2021-09-28

    Thor Motor Coach Recalls 2021-2022 Venetian Motorhomes for Awning Defect

    Thor Motor Coach is recalling 2021-2022 Venetian motorhomes because improperly installed patio awnings may separate while driving, increasing crash risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH VENETIAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V522000·2021-07-08

    Recreational Vehicles Recalled for Thor Motor Coach Window Vent Failure

    Thor Motor Coach is recalling multiple RV models due to defective adhesive bonding in Hehr 6400 series windows. The vented portion may detach, increasing risk of crash or injury.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH ARIA, VENETIAN, PALAZZO, OUTLAW
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V441000·2021-06-10

    Thor Motor Coach Motorhomes Recalled for Missing LP Tank Heat Shield

    Thor Motor Coach is recalling 2018-2022 Axis and 2018-2021 Vegas motorhomes with missing heat shields between the LP tank and chassis muffler. A missing heat shield increases fire risk; dealers will install the shield free of charge.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH AXIS, VEGAS, redundant AXIS, redundant VEGAS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V396000·2021-05-26

    2022 Thor Motor Coach RV models recalled for solar panel fire risk

    Thor Motor Coach is recalling certain 2022 Sequence, Rize, Scope, and Tellaro recreational vehicles. The Flex-190 solar panel junction box may experience electrical shorts, increasing the fire risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH RIZE, SCOPE, SEQUENCE, TELLARO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V804000·2020-12-21

    Thor Motor Coach Recalls 2018-2019 Hurricane and Windsport Motorhomes

    Thor Motor Coach is recalling 2018-2019 Hurricane and Windsport motorhomes because overhead cabinets may detach and fall on occupants.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH HURRICANE, WINDSPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V718000·2020-11-19

    2021 Thor Motor Coach Four Winds motorhomes recalled for stove gas leak

    Thor Motor Coach is recalling certain 2021 Four Winds motorhomes with Dometic stoves due to a potential gas leak that could increase fire risk. The stove's saddle valve bolt may be overtightened, damaging the seal.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH FOUR WINDS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V711000·2020-11-17

    Thor Motor Coach Motorhomes Electrical Fire Risk Battery Isolation Recall

    Thor Motor Coach is recalling certain 2020-2021 motorhomes. A faulty Battery Isolation Manager/Relay allows water into the engine compartment, creating electrical arcing and fire risk. Owners should contact TMC at 1-877-855-2867.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH FREEDOM ELITE, DAYBREAK, FOUR WINDS, QUANTUM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V679000·2020-11-04

    Thor Motor Coach Recalls 2010-2011 Four Winds Montecito Motorhomes

    Thor Motor Coach is recalling 2010-2011 Four Winds Montecito motorhomes because a transfer switch may fail due to heat, increasing fire risk.

    Product
    FOUR WINDS — FOUR WINDS MONTECITO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V559000·2020-09-15

    Thor Motor Coach Motorhomes Tire Valve Stem Defect Recall

    Thor Motor Coach is recalling certain 2018-2021 motorhomes because the tire valve stem extension may contact the rim and become damaged, potentially causing tire pressure loss and crash risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH TUSCANY, VENETIAN, ARIA, PALAZZO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V498000·2020-08-21

    Thor Motor Coach motorhomes recalled for potential electrical fire risk

    Thor Motor Coach is recalling 2019-2021 Windsport and Hurricane motorhomes due to a circuit board defect that could cause fire. The electrical control center may be damaged by voltages over 17 volts.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH HURRICANE, WINDSPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V458000·2020-08-05

    Thor Motor Coach Motorhomes Recalled: Pedestal Bolts May Fail During Crash

    Thor Motor Coach is recalling 2020-2021 Daybreak, 2018-2021 Four Winds, and 2018-2021 Chateau motorhomes because barrel chair pedestals are secured with bolts of the wrong size. In a crash, these pedestals could separate, causing seat belt anchorages to fail and increasing injury risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH redundant FOUR WINDS, redundant CHATEAU, DAYBREAK, FOUR WINDS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V444000·2020-07-29

    Thor Motor Coach motorhomes recalled for faulty swivel seat wiring harnesses

    Certain 2020-2021 Thor motorhomes with swivel seats have wiring harnesses that may be routed incorrectly, potentially causing side airbags to deploy inadvertently or fail during crashes. Owners should contact Thor or Mercedes-Benz for free inspection and repair.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH GEMINI, COMPASS, redundant SYNERGY, CHATEAU CITATION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V423000·2020-07-22

    Thor Motor Coach Motorhomes Recalled for Electrical System Fire Hazard

    Thor Motor Coach is recalling certain 2019-2021 Freedom Elite and 2021 Four Winds motorhomes due to an incorrect converter breaker installation that can cause wiring to overheat and increase fire risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH FOUR WINDS, FREEDOM ELITE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V424000·2020-07-22

    Thor Motor Coach Sequence Motorhomes Dinette Seat Belt Tethers Too Short

    Thor Motor Coach is recalling certain 2020-2021 Sequence and Tellaro motorhomes because the dinette booth seat belt tethers are too short, preventing safe use by some occupants and increasing crash injury risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH TELLARO, SEQUENCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V419000·2020-07-20

    2021 Thor Motor Coach motorhomes recalled for battery cable fire risk

    Thor Motor Coach is recalling 2021 motorhomes because an improperly secured battery cable may contact the exhaust manifold and pose a fire risk. Owners should contact Thor Motor Coach for a free inspection and repair.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH DAYBREAK, FOUR WINDS, QUANTUM, CHATEAU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V339000·2020-06-09

    2020 Thor Motor Coach motorhome frameless windows may detach while driving

    Thor Motor Coach is recalling certain 2020-2021 motorhomes because the adhesive bond in frameless windows may fail, allowing the glass to detach and become a projectile hazard while the vehicle is in motion.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH AXIS, COMPASS, DELANO, GEMINI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V312000·2020-05-28

    Thor Motor Coach Recalls 2020 Motorhomes for Brake Hose Chafing Risk

    Thor Motor Coach is recalling 566 2020 motorhomes because a fender liner may chafe the brake hose, potentially causing brake fluid loss and increased braking distance.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH CHATEAU CITATION, SIESTA, TIBURON, COMPASS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V303000·2020-05-27

    Motorhome wire harness may damage fuel pump and brake systems

    Certain 2020-2021 Thor Motor Coach motorhomes may have a wire harness that contacts the frame, potentially damaging fuel pump and brake circuits and increasing crash risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH AXIS, VEGAS, CHATEAU, FOUR WINDS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V308000·2020-05-27

    Thor Motor Coach Recalls 2020 Motorhomes Due to Manual Error

    Thor Motor Coach is recalling 566 2020 motorhomes because the owner's manual incorrectly describes the automatic parking function, which could lead to vehicle rollaway.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH, THOR SIESTA, SYNERGY, GEMINI, DELANO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V178000·2020-03-25

    Thor Motor Coach motorhomes recalled for faulty rear axle differential

    Thor Motor Coach is recalling certain 2020-2021 motorhomes due to insufficient rear axle differential fluid that could cause driveshaft separation and loss of vehicle drive, increasing crash risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH VEGAS, AXIS, CHATEAU, FOUR WINDS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V148000·2020-03-17

    2020 Thor Sequence motorhomes recalled for transmission shifter cable separation

    Thor Motor Coach is recalling 2020 SEQUENCE motorhomes because the transmission shifter cable may separate from the transmission, potentially causing unintended vehicle movement and increased crash risk.

    Product
    THOR — THOR, THOR MOTOR COACH SEQUENCE, TELLARO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V799000·2019-11-07

    Thor Motor Coach Recalls Tuscany and Venetian Motorhomes for Visibility Defect

    Thor Motor Coach is recalling specific Tuscany and Venetian motorhomes because rear reflectors may be positioned too high, reducing vehicle visibility and increasing crash risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH TUSCANY, TUSCANY XTE, VENETIAN
    Category
    Vehicle
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Thor Motor Coach, Inc.

Country
United States
Parent company
Thor Industries

Source: Wikidata (Q131433520), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.