The Recall Desk

Manufacturer

Navistar, Inc.

264 recalls in our database name Navistar, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
264
Critical
0
Severe
156
Most recent
2024-10-02

Of the 264 recalls from Navistar, Inc. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 156 (59%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–25 of 264

  • SevereNHTSA·24V750000·2024-10-02

    School buses recalled for brake caliper mounting bolt defect

    Navistar is recalling 2024-2025 IC Bus school buses because brake caliper mounting bolts may not be properly tightened, allowing the brake caliper to detach and cause loss of braking ability. Owner notification was sent in November 2024.

    Product
    IC BUS — IC BUS CESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V734000·2024-10-01

    2025 International HX and LT vehicles recalled for fuel pump fracture risk

    Navistar is recalling 2025 International HX and LT vehicles with Cummins X15 diesel engines due to fuel pump barrel fracture risk. The fracture can cause fuel leaks and engine stalls, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL HX, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V556000·2024-07-25

    Second Navistar recall covers incorrectly heat treated tie rod ball studs

    A second Navistar recall covers certain 2025 International HV, HX, LT, MV and RH vehicles whose tie rod ball studs may have been incorrectly heat-treated. 573 units affected.

    Product
    INTERNATIONAL — INTERNATIONAL HX, LT, RH, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V462000·2024-06-20

    International truck tie rod ball studs were incorrectly heat treated

    Navistar is recalling certain 2025 International HV, LT, MV and RH trucks because tie rod ball studs may have been incorrectly heat-treated and can break. 116 units affected.

    Product
    INTERNATIONAL — INTERNATIONAL RH, HV, MV, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V463000·2024-06-20

    Navistar Recalls 2025 IC Bus CE School Buses for Tie Rod Defect

    Navistar is recalling 2025 IC Bus CE school buses because incorrectly heat-treated tie rod assemblies may break, potentially causing loss of steering control.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V341000·2024-05-15

    Navistar Recalls 2024-2025 IC Bus School Buses for Brake Defect

    Navistar is recalling 2024-2025 IC Bus school buses because a faulty valve module may cause park brake failure or unexpected engagement.

    Product
    IC BUS — IC BUS CESB, CE SBUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V180000·2024-03-07

    2025 International LT vehicles recalled for reversed turn signal wiring

    Navistar is recalling certain 2025 International LT vehicles because two wires in the taillight jumper harness may be reversed, causing turn signals to activate in the wrong direction. This safety defect may confuse other road users and increase crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V164000·2024-02-29

    International truck steering gear teeth can crack causing steering loss

    Navistar is recalling certain 2025 International HV, HX, LT and MV vehicles because an improperly heat-treated steering gear sector shaft can crack or fracture, causing a loss of steering control.

    Product
    INTERNATIONAL — INTERNATIONAL LT, HX, MV, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V088000·2024-02-08

    2024 International Trucks Steering Defect May Cause Loss of Control

    Navistar recalls 2024-2025 International trucks and 2024 IC Bus commercial buses due to steering gear assemblies that may be incorrectly assembled, potentially causing loss of steering control.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS MV, HV, HX, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V089000·2024-02-08

    Navistar Recalls 2024 IC Bus CE School Buses for Steering Defect

    Navistar is recalling 2024 IC Bus CE school buses because steering gear assemblies may have fewer recirculating balls than required, risking loss of steering control.

    Product
    IC BUS — IC BUS CE SBUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V026000·2024-01-18

    Navistar Recalls 2024 International HV and MV Trucks for Seat Belt Defect

    Navistar is recalling 2024 International HV and MV trucks because the driver's seat belt tether bolt may not be properly seated, increasing injury risk in a crash.

    Product
    INTERNATIONAL — INTERNATIONAL HV, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V027000·2024-01-18

    Navistar Recalls 2024 IC EV School Buses for Mislabeled Cables

    Navistar is recalling 2024 IC EV school buses because high-voltage cables may be mislabeled, posing an electrical shock risk to technicians.

    Product
    IC BUS — IC BUS EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V587000·2023-08-17

    2023 International HV and MV Driveshaft Failure Recall

    Navistar recalls certain 2023 International HV and MV vehicles; driveshafts may break under certain conditions, causing loss of drive power and increasing crash risk. Replacement is free.

    Product
    INTERNATIONAL — INTERNATIONAL MV, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V397000·2023-06-02

    Commercial Buses and Trucks Recalled for Brake Pressure Switch Fire Risk

    Navistar is recalling certain IC BUS and International commercial buses and trucks due to a brake pressure switch defect that may cause electrical short and fire risk. Owners should park vehicles outside until repairs are completed.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS MV, DURASTAR, 1300FBC, TC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V398000·2023-06-02

    IC Bus CESB school buses recalled for brake pressure switch fire risk

    Navistar is recalling certain IC Bus CESB school buses with brake pressure switch assemblies that may leak brake fluid and cause electrical short-circuits, creating a fire risk while driving or parked.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V371000·2023-05-25

    IC Bus school buses recalled for ABS warning light failure

    IC Bus school buses (2021–2024) are being recalled because the anti-lock brake system warning light fails to illuminate during malfunctions, preventing drivers from being alerted and increasing crash risk.

    Product
    IC BUS — IC BUS CESB, RESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V370000·2023-05-25

    2022-2024 International Trucks: ABS Warning Light Fails to Illuminate

    Navistar is recalling certain 2021-2024 International trucks and buses whose anti-lock brake system warning light fails to illuminate when malfunctions occur. Drivers will not be alerted to brake system problems, increasing the risk of crashes.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS LONESTAR, RH, LT, HX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V353000·2023-05-18

    Navistar International trucks recalled for inadequate back-up light visibility

    Navistar is recalling certain International trucks (2000-2024 model years) for inadequate back-up light visibility when reversing. Low visibility may not alert other drivers, increasing crash risk. Dealers will replace rear stop/turn signal lights free of charge.

    Product
    INTERNATIONAL — INTERNATIONAL MV, 9400I, 9100I, 9200I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V322000·2023-05-04

    2023 International MV Trucks: Driveshaft Weld Defect Recall

    Navistar is recalling 49 2023 International MV trucks because the driveshaft tube seam weld may separate or tear, causing sudden loss of drive power and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V282000·2023-04-20

    International CV Brake Pressure Switch Fire Risk Recall

    Navistar is recalling 2017-2023 International CV trucks for a brake pressure switch assembly defect that may leak brake fluid and cause an electrical short-circuit, increasing fire risk while driving or parked.

    Product
    INTERNATIONAL — INTERNATIONAL CV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V248000·2023-04-06

    Navistar Recalls International Buses Due to HVAC Wiring Fire Risk

    Navistar is recalling 2016-2020 International and IC Bus models because an HVAC wiring terminal may overheat, increasing the risk of a fire.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS TRANSTAR, DURASTAR, PROSTAR, LONESTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V220000·2023-03-30

    International LT and RH Trucks Engine Control Module Software Issue

    Navistar is recalling 2021–2024 International LT and RH trucks because the engine control module may become unresponsive to throttle pedal input, causing the vehicle to unexpectedly slow to idle speed while driving, which increases crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LT, RH
    Category
    Vehicle
    Distribution
    Distributed nationwide