The Recall Desk

Hazard

Water Ingress recalls

30 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
30
Critical
0
Severe
10
Most recent
2026-03-27

Of the 30 water ingress recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 10 (33%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all water ingress recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 30

  • SevereNHTSA·26V196000·2026-03-27

    KTM 390 electronic throttle control may fail after water entry

    KTM is recalling certain 2022-2023 390 Duke and 2022-2024 RC 390 motorcycles because water may enter the electronic throttle control unit and cause it to fail, losing drive power while riding.

    Product
    KTM — KTM RC 390, 390 DUKE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V070000·2026-02-06

    Mercedes-Benz Metris air bag control unit may accumulate water

    Daimler Vans USA is recalling certain 2020 and 2022-2023 Mercedes-Benz Metris right-hand-drive vehicles because water may accumulate on the air bag control unit and stop the air bags deploying as intended.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ METRIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V893000·2025-12-18

    Hyundai Tucson tow hitch harness may let water reach the module

    Hyundai is recalling certain 2022-2024 Tucson vehicles with an optional Mobis tow hitch wiring harness because incorrect installation may allow water into the control module.

    Product
    HYUNDAI — HYUNDAI TUCSON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V645000·2025-09-25

    Range Rover Evoque rearview camera can admit water distorting the image

    Land Rover is recalling certain 2023 Range Rover Evoque vehicles because water may enter the rearview camera, so the image may not appear on the display or may appear distorted.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER EVOQUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V598000·2025-09-11

    Motorcycles recalled because water in the throttle control can cause power loss

    KTM North America is recalling certain Husqvarna Svartpilen 401, Vitpilen 401 and KTM 390 Adventure motorcycles because water could enter the e-throttle control unit and cause loss of drive power. 9,070 units are affected.

    Product
    HUSQVARNA — HUSQVARNA, KTM SVARTPILEN 401, VITPILEN 401, 390 ADVENTURE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V546000·2025-08-22

    Ford Mustang water ingress can disable tail and marker lights

    Ford is recalling certain 2024-2025 Mustang and Mustang GTD vehicles because water may enter the body control module and cut communication with the licence plate, side marker and tail lights.

    Product
    FORD — FORD MUSTANG
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V510000·2025-08-08

    Lincoln Corsair rearview cameras can take in water at the connectors

    Ford is recalling certain 2020-2022 Lincoln Corsair vehicles because water may enter the rearview camera connectors, causing the image not to appear or to display distorted. 41,875 vehicles affected.

    Product
    LINCOLN — LINCOLN CORSAIR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V947000·2024-12-19

    Range Rover rearview cameras may admit water and distort the image

    Land Rover is recalling certain 2022-2023 Range Rover vehicles because water may enter the rearview camera, blanking or distorting the image. 11,961 units are affected.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V806000·2024-10-25

    Ford Super Duty tailgate camera modules may admit water

    Ford is recalling certain 2023-2024 F-250, F-350 and F-450 vehicles because water may enter the tailgate park assist module and disrupt the rearview camera image.

    Product
    FORD — FORD F-450 SD, F-350 SD, F-250 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V651000·2024-09-04

    2021-2024 Volkswagen ID.4 Door Handles May Fail Due to Water Ingress

    Volkswagen is recalling 2021-2024 ID.4 vehicles because door handles may allow water to enter the circuit board, causing doors to open unexpectedly while driving. Owners should contact Volkswagen dealers for free inspection and repair.

    Product
    VOLKSWAGEN — VOLKSWAGEN ID.4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24345·2024-08-15

    DeWALT Battery Walk-Behind Mowers Recalled for Laceration Hazard

    Stanley Black & Decker is recalling about 46,200 DeWALT Battery walk-behind mowers because water entering the handle support can cause the mower to fail to shut off or start without a key, posing a laceration risk.

    Product
    DeWALT Battery Push walk-behind mowers and DeWALT Battery Self-Propelled walk-behind mowers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V364000·2024-05-23

    Range Rover Sport rearview cameras may admit water and distort

    Land Rover is recalling certain 2018-2022 Range Rover Sport vehicles with a Surround Camera System because water may enter the rearview camera, blanking or distorting the image.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V302000·2024-04-29

    MINI Cooper SE battery housing can admit water causing fire or stall

    BMW is recalling certain 2020-2024 MINI Hardtop 2 Door (Cooper SE) vehicles because the high voltage battery housing may not have been sealed properly, allowing water to enter the battery.

    Product
    MINI — MINI COOPER SE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V274000·2024-04-17

    Toyota Prius Prime rear door opener switch water intrusion recall

    Toyota is recalling 2023–2024 Prius and Prius Prime vehicles because water may enter the rear door switch, causing it to short circuit and allow the rear door to open unexpectedly while driving or during a crash.

    Product
    TOYOTA — TOYOTA PRIUS, PRIUS PRIME
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V312000·2023-05-03

    Volkswagen ID.4 Door Handles May Open Unexpectedly Due to Water Intrusion

    Certain 2021-2022 Volkswagen ID.4 vehicles have door handles that may allow water to enter the circuit board assembly, potentially causing doors to open unexpectedly while driving. Volkswagen will update vehicle software and inspect door handles at no cost to owners.

    Product
    VOLKSWAGEN — VOLKSWAGEN ID.4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V771000·2022-10-13

    GM Recalls 2022-2023 Hummer EV and BrightDrop EV600 for Battery Seal Defect

    General Motors is recalling 2022-2023 Hummer EV Pickups and 2022 BrightDrop EV600s because the high-voltage battery pack may not be sealed, allowing water entry that can cause loss of drive power.

    Product
    GMC — GMC, BRIGHTDROP HUMMER EV PICKUP, EV600
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1525-2022·2022-08-31

    Intensive care ventilator status board may loosen, causing water damage and malfunction

    Hamilton's HAMILTON-C6 intensive care ventilator status indicator board may become loose, allowing water or disinfectants to enter the device and cause technical faults that could force the ventilator into unsafe modes where patients breathe unassisted room air.

    Product
    HAMILTON-C6 Intensive Care Ventilator, REF: 160021
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·22V033000·2022-01-26

    2021 Toyota Venza Hybrid rear turn signal lighting system failure recall

    Toyota is recalling certain 2021 Venza Hybrid vehicles due to water intrusion in rear turn signal lights, which can cause electrical short circuits and lighting failure, increasing crash risk.

    Product
    TOYOTA — TOYOTA VENZA HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V947000·2021-12-08

    Audi SQ5 and Q5 recalled for water ingress into control module

    Volkswagen Group of America (Audi) is recalling certain 2018–2022 Audi Q5 and SQ5 vehicles. Water or liquid can seep into the gateway control module, causing sudden engine power loss and increasing crash risk.

    Product
    AUDI — AUDI Q5, SQ5, Q5 SPORTBACK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V416000·2020-07-17

    Mercedes-Benz Recalls 2019 A 220 Vehicles for Electrical Water Ingress Risk

    Mercedes-Benz is recalling 2019 A 220 vehicles because a poorly installed air conditioning drain hose may allow water to enter electrical components, potentially causing system malfunctions.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ A 220
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2197-2020·2020-06-10

    Olympus ShockPulse-SE Lithotripsy Transducers Recalled for Material Defect

    Olympus is recalling 18 ShockPulse-SE Lithotripsy System transducers because a component was made with non-conforming material that could allow water ingress during sterilization.

    Product
    OLYMPUS ShockPulse-SE Lithotripsy System, Model SPL-T Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0175-2019·2018-10-24

    Philips HeartStart FR3 Defibrillators Recalled for Water Ingress Risk

    Philips is recalling 432 HeartStart FR3 defibrillators because they may not meet water resistance specifications, potentially causing device failure if water enters.

    Product
    Philips HeartStart FR3 Defibrillator, Model: 861388, 861389 Product Usage: The HeartStart FR3 is used to treat suspected victims of ventricular fibrillation (VF), the most common cause of sudden cardiac arrest (SCA), and certain ventricular tachycardia (VTs). Both models are…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0067-2019·2018-10-10

    Heartware HVAD System Controllers Recalled for Potential Water Ingress

    Heartware, Inc. is recalling HVAD System Controllers because they may develop hairline cracks at the power ports, potentially failing to meet standards for protection against water or fluid ingress.

    Product
    Heart Ware(TM) HVAD(TM) System Controller/Controller Kits, Model Numbers: 1403, 1407, and 1420 Product Usage: The HeartWare HVAD System is indicated for hemodynamic support in patients with advanced, refractory left ventricular heart failure; either as a Bridge to Cardiac…
    Category
    Medical Device
    Distribution
    0 states