The Recall Desk

Category

Vehicle recalls

NHTSA recalls of passenger vehicles, motorcycles, tires, and child seats.

About vehicle recalls

Vehicle recalls in our database all come from NHTSA. They cover passenger cars, light trucks, SUVs, motorcycles, tires, child safety seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA Campaign Number (a string like 25V123000) and lists every make / model / year combination affected. We carry the full vehicle range so you can search by your own car.

The most common vehicle-recall categories are airbag and seatbelt failures (the consequence is non-deployment in a crash), fuel system defects with fire risk, steering or brake malfunctions, electrical defects in EVs that can cause battery thermal events, software bugs in driver-assist systems, and child-seat harness failures. Recalls for tires almost always relate to a tread-separation risk in a defined production date range.

Every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, with no expiration. If your vehicle has an open recall, your dealer is required to perform the remedy free of charge as long as the vehicle exists. If you're not sure whether your vehicle is affected, the VIN lookup decodes your specific vehicle and cross-references the NHTSA database directly.

2526–2550 of 15584

  • HighNHTSA·24V357000·2024-05-21

    Vermeer Recalls BC900XL Trailers Due to Incorrect Manual Torque Values

    Vermeer is recalling 2015-2022 BC900XL brush chipper trailers because the service manuals list incorrect lug nut torque values, which could lead to wheel detachment.

    Product
    VERMEER — VERMEER BC900XL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V354000·2024-05-20

    ATC Recalls 2021-2024 Toy Hauler Trailers Due to Fire Risk

    ATC is recalling 2021-2024 Toy Hauler trailers because a faulty LED circuit board in the cooktop may overheat and cause a fire.

    Product
    ATC — ATC TOYHAULER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V353000·2024-05-20

    FR Conversions Recalls 2023-2024 Ram Promaster Vehicles for Seat Defect

    FR Conversions is recalling 2023-2024 Ram Promaster vehicles because the seat recliner mechanism may not engage, increasing injury risk during a crash.

    Product
    FR CONVERSIONS — FR CONVERSIONS RAM PROMASTER CONVERSION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V352000·2024-05-17

    Braunability Recalls 2023-2024 Chrysler Wheelchair Vans for Seat Defect

    Braunability is recalling 2023-2024 Chrysler Voyager wheelchair vans because the seat recliner mechanism may not engage, increasing injury risk in a crash.

    Product
    BRAUNABILITY — BRAUNABILITY CHRYSLER WHEELCHAIR VAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V351000·2024-05-17

    2023–2025 Forest River Motorhomes Recalled for Unsecured LP Line

    Forest River is recalling certain 2023–2025 Solera, Forester, and Sunseeker motorhomes because the Liquid Propane line may not be properly secured, creating a fire risk if the line becomes damaged and leaks.

    Product
    FOREST RIVER — FOREST RIVER SUNSEEKER, SOLERA, FORESTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V348000·2024-05-16

    2024 Lamborghini Urus Hood Latch May Separate While Driving

    Lamborghini is recalling 2023-2024 Urus Performante and Urus S vehicles because the hood latch striker may separate, causing the hood to open or detach while driving and create a road hazard.

    Product
    LAMBORGHINI — LAMBORGHINI URUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V346000·2024-05-16

    2024 Jeep Grand Cherokee: Missing Bumper Foam May Prevent Airbag Deployment

    Certain 2024 Jeep Grand Cherokees may be missing foam in the front bumper, which could prevent the front airbags from deploying during a crash. Dealers will install the foam at no cost.

    Product
    JEEP — JEEP GRAND CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V347000·2024-05-16

    Custom Truck Recalls 2020 Ford F-550 for Electrical Fire Risk

    Custom Truck is recalling one 2020 Ford F-550 because a wiring fault may cause electrical circuits to overheat and increase fire risk.

    Product
    CUSTOM TRUCK & BODY WORKS — CUSTOM TRUCK & BODY WORKS FORD F-550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V349000·2024-05-16

    Mazda Recalls 2024 CX-90 Vehicles for Automatic Braking Defect

    Mazda is recalling 2024 CX-90 vehicles because the automatic emergency braking system may falsely detect objects, causing sudden braking and increasing crash risk.

    Product
    MAZDA — MAZDA CX-90
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V342000·2024-05-15

    Morbark Brush Chippers Recalled for Fuel Line Fire Risk

    Alamo Group is recalling 2023-2024 Morbark brush chippers because fuel lines may lack the required pressure rating, creating a fire hazard.

    Product
    MORBARK — MORBARK EEGER BEEVER 1922, EEGER BEEVER 2131, EEGER BEEVER 1821
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V343000·2024-05-15

    Porsche Recalls 2024 718 Models Due to Shift Cable Installation Issue

    Porsche is recalling 2024 718 Cayman and Boxster vehicles because a safety clip may not be installed properly, potentially preventing the transmission from locking in park.

    Product
    PORSCHE — PORSCHE 718 CAYMAN, 718 BOXSTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V345000·2024-05-15

    BMW 2024-2025 X5, X6, X7, XM, and Alpina XB7 Seat Belt Detection System Defect

    BMW recalls certain 2024-2025 X5, X6, X7, XM, and Alpina XB7 models due to a seat belt detection system defect that may fail to alert drivers of unbuckled passengers or allow proper deployment of the supplemental restraint system.

    Product
    BMW — BMW ALPINA XB7, X6, XM, X5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V341000·2024-05-15

    Navistar Recalls 2024-2025 IC Bus School Buses for Brake Defect

    Navistar is recalling 2024-2025 IC Bus school buses because a faulty valve module may cause park brake failure or unexpected engagement.

    Product
    IC BUS — IC BUS CESB, CE SBUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V340000·2024-05-15

    2025 MINI Countryman Rear Armrest May Detach During Airbag Deployment

    BMW is recalling 9 2025 MINI Countryman vehicles because the armrest support bracket on the rear side door panel may be improperly secured and detach during an airbag deployment, potentially striking occupants or interfering with airbag function.

    Product
    MINI — MINI COUNTRYMAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V344000·2024-05-15

    2021-2023 Volkswagen ID.4 display software defect increases crash risk

    Certain 2021-2023 Volkswagen ID.4 vehicles experience a software issue causing display failures that hide the speedometer and rearview camera. Dealers will update the software at no cost.

    Product
    VOLKSWAGEN — VOLKSWAGEN ID.4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V339000·2024-05-15

    Multiple travel trailers recalled for detaching freshwater tanks

    Forest River travel trailers may have freshwater tanks that detach when full, posing a road hazard. Dealers will install additional attachment straps at no cost.

    Product
    VIKING TOWABLE — VIKING TOWABLE, CLIPPER TOWABLE, INDEPENDENCE TRAIL TRAILE VWT182DBU, VWT262BHS, VWT26SBHSAGA, VWT272RLS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V335000·2024-05-14

    2025 Freightliner Business Class M2 park brake failure recall

    Daimler Trucks North America is recalling 2024-2025 Freightliner Business Class M2 vehicles because the park brake valve module may leak, causing park brake failure or unexpected engagement while driving.

    Product
    FREIGHTLINER — FREIGHTLINER BUSINESS CLASS M2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V336000·2024-05-14

    Thomas Built Buses Recalls 2024-2025 SAF-T-Liner C2 Models for Brake Defect

    Daimler Trucks North America is recalling 2024-2025 Thomas Built SAF-T-Liner C2 school buses because a seal defect may cause parking brake failure or unexpected engagement.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER C2 JOULEY, SAF-T-LINER C2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V338000·2024-05-14

    2024 Kia EV9 Front Passenger Seat Belt Retractor May Fail

    Kia is recalling certain 2024 EV9 vehicles because the front passenger seat belt retractor cover may not be properly secured, which can prevent the seat belt from locking correctly during a crash.

    Product
    KIA — KIA EV9
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V333000·2024-05-14

    Mack MD and Terrapro trucks recalled for incorrect weight rating

    Mack is recalling certain 2024-2025 MD and Terrapro vehicles because the Gross Axle Weight Rating (GAWR) on the certification label is incorrect, allowing vehicles to be overloaded and increasing crash risk. Dealers will replace the label free of charge.

    Product
    MACK — MACK TERRAPRO (TE), MD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V332000·2024-05-13

    ABC Bus Recalls Van Hool CX35 and CX45 Due to Heater Exhaust Risk

    ABC Bus is recalling 2023-2024 Van Hool CX35 and CX45 buses because Hydronic L-II heaters may release excessive exhaust gas, posing a risk of smoke poisoning or fire.

    Product
    VAN HOOL — VAN HOOL CX35, CX45
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V334000·2024-05-13

    Winnebago Recalls 2020 Commercial Vehicle for Wheelchair Lift Defect

    Winnebago is recalling one 2020 Commercial vehicle because the wheelchair lift's outer barrier may deploy unexpectedly, increasing injury risk.

    Product
    WINNEBAGO — WINNEBAGO COMMERCIAL VEHICLE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V330000·2024-05-10

    Lincoln Corsair transmission control software defect causes unexpected neutral shift

    Ford is recalling 2021-2022 Lincoln Corsair vehicles due to a hybrid powertrain control module software defect that may cause the transmission to shift into neutral unexpectedly, resulting in loss of drive power and increased crash risk.

    Product
    FORD — FORD, LINCOLN MAVERICK, ESCAPE, CORSAIR
    Category
    Vehicle
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.