The Recall Desk

Vehicle

Kenworth T680 · 2021

7 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–7 of 7

  • Severity pendingNHTSA·25V181000·2025-03-24

    Peterbilt and Kenworth high voltage contactors can open cutting drive power

    PACCAR is recalling certain 2021-2025 Peterbilt 520, 579 and Kenworth T680 trucks because the high voltage contactors may open, causing a sudden loss of high voltage and drive power.

    Product
    KENWORTH — KENWORTH, PETERBILT T680, 579, 520
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V145000·2024-02-23

    Kenworth trucks fitted with air tanks holding insufficient brake air

    PACCAR is recalling certain 2009-2024 Kenworth trucks because the air tanks have an insufficient volume of air for the brake system, which can reduce braking performance.

    Product
    KENWORTH — KENWORTH C500, T370, T680, T880
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V593000·2020-09-28

    Kenworth T680 Trucks Recalled for Brake System Valve Defect

    PACCAR is recalling 2016-2021 Kenworth T680 trucks because a brake valve defect may increase stopping distance and crash risk.

    Product
    KENWORTH — KENWORTH T680
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V915000·2024-12-09

    Kenworth and Peterbilt Trucks Recalled for Faulty Electronic Control Units

    PACCAR is recalling 2021-2025 Kenworth and Peterbilt commercial trucks with defective electronic control units that may fail due to electrical interference, potentially disabling critical safety systems including ABS, traction control, and electronic stability control.

    Product
    KENWORTH — KENWORTH, PETERBILT W900B, T800B, 348, 389
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·24V190000·2024-03-20

    PACCAR gear shifter stalk connectors may lose communication with the transmission

    PACCAR is recalling certain Peterbilt and Kenworth trucks because improperly crimped gear shifter stalk connectors may cause a loss of communication. 70,509 units affected.

    Product
    PETERBILT — PETERBILT, KENWORTH 537, T180, T680, 365
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V00N000·2021-12-29

    Kenworth and Peterbilt Commercial Trucks Recalled for Methane Detection System Failure

    PACCAR is recalling approximately 1,107 Kenworth and Peterbilt commercial trucks (2016–2022) due to methane detection system power loss. If the system loses electrical power, operators may not detect dangerous methane levels, increasing fire and injury risk.

    Product
    KENWORTH — KENWORTH, PETERBILT T680, T880, 567, 536
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V080000·2021-02-17

    2021-2022 Kenworth and Peterbilt trucks recalled for improperly torqued flywheel attachment

    PACCAR is recalling certain 2021-2022 Kenworth and Peterbilt heavy trucks equipped with Cummins X15 engines. The flywheel attachment capscrews may be improperly torqued, risking flywheel detachment and loss of drive power.

    Product
    PETERBILT — PETERBILT, KENWORTH 389, 567, T800B, W900
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all Kenworth models