The Recall Desk

Vehicle

Freightliner Sprinter 4500 · 2021

11 recalls affect this vehicle. Sorted by severity, then date.

Filter by model year

1–11 of 11

  • Severity pendingNHTSA·23V875000·2023-12-21

    Daimler Recalls 2019-2021 Sprinter Vans for Frame Fastener Defect

    Daimler Vans USA is recalling 2019-2021 Mercedes-Benz and Freightliner Sprinter vans because missing frame fasteners may reduce stability and structural integrity.

    Product
    FREIGHTLINER — FREIGHTLINER, MERCEDES-BENZ SPRINTER 3500, SPRINTER 2500, SPRINTER 1500, SPRINTER 4500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V933000·2021-12-01

    2021 Mercedes-Benz Sprinter Vehicles Recalled for Brake Hose Damage Risk

    Daimler Vans USA is recalling 2021 Mercedes-Benz and Freightliner Sprinter vans because the front fender liner may damage the brake hose, increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER SPRINTER 3500, SPRINTER 4500, SPRINTER 1500, SPRINTER 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V876000·2023-12-21

    Mercedes-Benz and Freightliner Sprinter Partition Wall Recall for Missing Bolts

    Daimler Vans USA is recalling 2019-2023 Mercedes-Benz and 2019-2021 Freightliner Sprinter vehicles whose partition walls may have missing bolts. The loose wall could detach during a crash, increasing injury risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER SPRINTER 3500, SPRINTER 2500, SPRINTER 1500, SPRINTER 4500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V806000·2023-12-01

    Freightliner and Mercedes Sprinter paint defect causes window and rail detachment

    Daimler Vans USA is recalling Freightliner and Mercedes-Benz Sprinter vans from 2021-2023 due to insufficient paint adhesion that may cause windows and interior lashing rails to detach during a crash. No injuries have been reported.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER SPRINTER 1500, SPRINTER 4500, SPRINTER 2500, SPRINTER 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V204000·2023-03-24

    Instrument Cluster Display Failure on 2019-2022 Sprinter Vans Recalled

    Daimler Vans USA is recalling 2019-2022 Mercedes and 2019-2021 Freightliner Sprinters because the instrument cluster may fail to display information. A blank dashboard prevents drivers from seeing speed, fuel level, and warnings, increasing crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER, MERCEDES-BENZ SPRINTER 3500, SPRINTER 2500, SPRINTER 1500, SPRINTER 4500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V796000·2022-10-21

    Freightliner Sprinter parking brake failure may cause vehicle rollaway

    The guide bushing on the parking pawl may fatigue and prevent the parking brake from engaging, risking vehicle rollaway. Dealers will provide a free software update to affected 2019-2022 vehicles.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER SPRINTER 3500, SPRINTER 2500, SPRINTER 1500, SPRINTER 4500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V360000·2022-05-20

    Daimler Recalls 2019-2021 Sprinter Vehicles for eCall Software Defect

    Daimler Vans USA is recalling 2019-2021 Freightliner and Mercedes-Benz Sprinter vehicles because a software error may disable the emergency call system.

    Product
    FREIGHTLINER — FREIGHTLINER, MERCEDES-BENZ SPRINTER 3500, SPRINTER 4500, SPRINTER 2500, SPRINTER 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V281000·2022-04-27

    Daimler Recalls 2019-2021 Sprinter Vehicles for Rearview Camera Software Error

    Daimler Vans USA is recalling 2019-2021 Freightliner and Mercedes-Benz Sprinter vans because a software error may prevent the rearview camera from displaying an image.

    Product
    FREIGHTLINER — FREIGHTLINER, MERCEDES-BENZ SPRINTER 4500, SPRINTER 1500, SPRINTER 2500, SPRINTER 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V513000·2021-07-07

    2021 Mercedes-Benz Sprinter and Freightliner Vehicles Recalled for Seat Belt Defect

    Daimler Vans USA is recalling 2021 Mercedes-Benz Sprinter, Metris, and Freightliner Sprinter vehicles because seat belt retractors may deactivate early, preventing child restraints from securing properly.

    Product
    FREIGHTLINER — FREIGHTLINER, MERCEDES-BENZ SPRINTER 2500, SPRINTER 3500, SPRINTER 4500, SPRINTER 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V410000·2021-06-02

    Mercedes-Benz Sprinter Recall for Swivel Seat Wiring Harness Defect

    Daimler Vans USA is recalling 2019-2021 Mercedes-Benz and Freightliner Sprinter vans with swivel seats because incorrect wiring harness routing may damage the seat air bag system.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER SPRINTER 4500, SPRINTER 3500, SPRINTER 1500, SPRINTER 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V411000·2021-06-02

    Mercedes-Benz and Freightliner Sprinter Recalled for Rearview Camera Software Defect

    Daimler Vans USA is recalling 2019-2021 Mercedes-Benz and Freightliner Sprinter vans because a software defect may cause the rearview camera image to fail to display.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER SPRINTER 2500, SPRINTER 1500, SPRINTER 3500, SPRINTER 4500
    Category
    Vehicle
    Distribution
    Distributed nationwide

← Back to all Freightliner models