  • ModerateFDA (Devices)·Z-0966-2024·2024-02-07

    Medline Blood Culture Collection Kit Recalled for Undocumented Component Expiration

    Medline is recalling blood culture collection kits because the Bactec component expiration date is not documented on the kit insert. Users who do not check the component directly risk using an expired element.

    Product
    MEDLINE BLOOD CULTURE COLLECTION KIT, Reorder Number DYNDH1626B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V072000·2024-02-06

    Mitsubishi Fuso Rizon Trucks Recalled for Unexpected Drive Power Loss

    Mitsubishi Fuso is recalling 2024 Rizon FEC7K and FEC9K trucks because a control unit error may cause the vehicle to shut down unexpectedly, increasing crash risk.

    Product
    MITSUBISHI FUSO — MITSUBISHI FUSO RIZON FEC7K (E16), RIZON FEC9K (E18)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24E007000·2024-02-05

    Worldwide Recalls INGUSA/LP ASME Remote Fill Tanks Due to Leak Risk

    Worldwide Distribution is recalling INGUSA/LP ASME Remote fill tanks because the liquid level remote fill gauge may leak in the open position, increasing fire risk.

    Product
    EQUIPMENT:RECREATIONAL VEHICLE/TRAILER:LPG SYSTEMS:TANK VALVE/GAUGE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V069000·2024-02-02

    Indian Challenger and FTR Motorcycles Recalled for Unintended Brake Light Illumination

    Indian Motorcycle Company is recalling certain 2019-2022 Challenger, FTR 1200, and Pursuit motorcycles due to brake lights that may illuminate unexpectedly without rider input, potentially confusing following drivers and increasing crash risk.

    Product
    INDIAN — INDIAN PURSUIT DARK HORSE, FTR 1200 S, FTR1200, CHALLENGER LIMITED
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V068000·2024-02-02

    Blue Bird Recalls 2021-2024 Vision School Buses for Stop Arm Defect

    Blue Bird is recalling 2021-2024 Vision school buses because a software defect may cause warning lights to turn off and the stop arm to retract unexpectedly.

    Product
    BLUE BIRD — BLUE BIRD VISION SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V066000·2024-02-02

    Forest River Salem and Wildwood travel trailers incorrect tire size

    Forest River is recalling 2023-2024 Salem and Wildwood fifth wheel travel trailers due to incorrect tire size information on their federal placards. This could lead to wrong tire installation and increased crash risk.

    Product
    FOREST RIVER — FOREST RIVER SALEM, WILDWOOD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V070000·2024-02-02

    2019-2022 Mercedes-Benz GLC models recalled for incorrect headlight adjustment and glare

    Mercedes-Benz is recalling 2019-2022 GLC 300, 2020 GLC 350e, and 2020-2022 AMG GLC 43 vehicles for headlights that may be incorrectly adjusted, creating glare for oncoming traffic. Dealers will correct the adjustment free of charge.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG GLC43, GLC 300, GLC 350 E
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V071000·2024-02-02

    Nissan LEAF rearview camera harness damage reduces rear visibility

    Nissan is recalling approximately 57,914 LEAF vehicles (2018-2022) where the rearview camera harness may become damaged, causing image distortion or loss and reducing rear visibility.

    Product
    NISSAN — NISSAN LEAF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V067000·2024-02-02

    Gulf Stream Trail Boss Trailers Recalled for Incorrect Tire Labeling

    Gulf Stream is recalling 2024 Trail Boss 160FK trailers because the federal certification label lists incorrect tire size and pressure, which could lead to improper tire installation.

    Product
    GULF STREAM — GULF STREAM TRAIL BOSS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalCPSC·24096·2024-02-01

    Fishing Games Recalled for High-Powered Magnet Ingestion Hazard

    Huihuang Trading is recalling Fishing Games sold on Amazon.com from June through July 2023 because they contain magnets that exceed federal safety limits. Swallowed magnets can become lodged in the digestive system and cause serious injury or death.

    Product
    Fishing Games
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalCPSC·24097·2024-02-01

    DailySale Magnetic DIY Balls Magic Cube Recalled for Ingestion Hazard

    DailySale Inc. is recalling its 216-piece 5mm Magnetic DIY Balls Magic Cube because the high-powered magnets violate federal toy safety regulations. When swallowed, the magnets can lodge in the digestive system and cause serious injury or death.

    Product
    Magnetic DIY Balls Magic Cube, 5mm
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V063000·2024-02-01

    Braun Ambulances Recall 2020-2024 Models Due to Electrical Fire Risk

    Braun Ambulances is recalling 628 emergency vehicles from 2020-2024 because a wiring defect could cause electrical circuits to overheat and start a fire.

    Product
    BRAUN AMBULANCES — BRAUN AMBULANCES CHIEF XL TYPE I, LIBERTY TYPE I, SIGNATURE SERIES TYPE III, SUPER CHIEF TYPE I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V060000·2024-02-01

    General Motors Recalls Pickup Trucks with Defective Power Tailgate Latches

    General Motors is recalling certain 2020-2024 Chevrolet Silverado and GMC Sierra pickup trucks due to faulty electronic tailgate switches that may inadvertently unlatch while the vehicle is parked. The defect can allow the tailgate to open while driving, potentially causing cargo loss and creating a road hazard.

    Product
    GMC — GMC, CHEVROLET SIERRA 3500, SILVERADO 2500, SILVERADO 3500, SIERRA 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·24107·2024-02-01

    BISSELL Multi Reach Hand and Floor Vacuum Cleaners Recalled for Fire Hazard

    BISSELL is recalling about 142,000 Multi Reach Hand and Floor Vacuum Cleaners because the battery pack can overheat and smoke, creating a fire risk. Six reports included the battery catching fire, causing minor property damage and burn injuries in some cases.

    Product
    BISSELL® brand Multi Reach Hand and Floor Vacuum Cleaners
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·24103·2024-02-01

    SRAM 12-Speed Shift Brake Levers Recalled Due to Crash Hazard

    SRAM is recalling about 61,300 12-speed shift brake levers because the clamp bolt can come loose, preventing proper braking and posing a crash hazard to riders. No injuries have been reported.

    Product
    Shift Brake Levers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·24101·2024-02-01

    Children's Nightgowns Recalled Due to Fire and Burn Hazard

    Stripe and Stare children's nightgowns violate federal flammability regulations for sleepwear, posing a risk of burn injuries. About 250 units sold online from February 2021 through January 2023.

    Product
    Children's nightgowns
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·24098·2024-02-01

    Lovevery Slide & Seek Ball Runs Recalled for Choking Hazard

    Lovevery is recalling about 47,000 Slide & Seek Ball Runs with wooden knobs because the wooden knob can detach during or after shipping, posing a choking hazard to children. The product was sold online as part of the Babbler Play Kit from June 2023 through November 2023.

    Product
    Slide & Seek Ball Runs with Wooden Knobs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V065000·2024-02-01

    2023 Hyundai IONIQ 5 and IONIQ 6 driveshaft replacement recall

    Hyundai is recalling 2023 IONIQ 5, IONIQ 6, and Genesis GV60 vehicles for rear driveshafts that may break under load due to improper heat treatment, causing loss of drive power. Dealers will replace the driveshaft free of charge.

    Product
    HYUNDAI — HYUNDAI, GENESIS IONIQ 6, IONIQ 5, GV60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24100·2024-02-01

    Ekouaer Girl's Nightgowns Recalled for Fire and Burn Hazard

    Ekouaer girl's nightgowns fail to meet federal flammability standards for children's sleepwear, posing a risk of burn injuries. About 16,800 units sold on Amazon from May 2020 through July 2023 are affected.

    Product
    Ekouaer Girl's Nightgowns
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·24095·2024-02-01

    Snap Recalls Lithium-Ion Battery for Pixy Flying Cameras Due to Fire Hazard

    Snap is recalling about 71,000 rechargeable lithium-ion batteries sold with Pixy Flying Cameras because the battery can overheat and pose a fire hazard. The company has received four reports of battery overheating and bulging, including one minor battery fire and one minor injury.

    Product
    Lithium-ion battery sold for Pixy Flying Cameras
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V061000·2024-02-01

    Motorhome Seat Pedestal Weld Defect Causes Unsafe Seat Separation Risk

    Jayco is recalling certain 2020-2023 Entegra motorhomes because passenger seats may have improperly welded pedestals that can separate and cause the seat to loosen or detach.

    Product
    ENTEGRA — ENTEGRA REATTA XL, CORNERSTONE, ANTHEM, ASPIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V064000·2024-02-01

    Multiple Honda and Acura models recalled for defective airbag sensor

    Honda and Acura are recalling 750,114 vehicles from 2020-2022 model years. A defective front passenger seat weight sensor may fail to suppress the airbag, increasing the risk of injury in a crash.

    Product
    HONDA — HONDA, ACURA ACCORD, INSIGHT, CR-V, CIVIC TYPE R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24104·2024-02-01

    NextGen Children's Bicycles Recalled for Safety Standard Violations

    Flat River Group is recalling about 22,700 NextGen children's bicycles because they do not meet federal safety standards. The bicycles lack required foot brakes, chain guards, or pedal reflectors, posing crash and injury hazards to children.

    Product
    NextGen Children's Bicycles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·24102·2024-02-01

    iFIT NordicTrack 50-Pound Adjustable Dumbbells Recalled for Impact Hazard

    iFIT is recalling NordicTrack 50-pound iSelect voice-controlled adjustable dumbbells because weight plates can dislodge during use, posing an impact hazard. Eight injuries including contusions and abrasions have been reported.

    Product
    NordicTrack 50 LB iSelect Voice-Controlled Adjustable Dumbbells
    Category
    Consumer Product
    Distribution