28 recalls in our database name New Flyer Industries Ltd. as the manufacturing or recalling firm.

What the numbers show

Total
28
Critical
0
Severe
19
Most recent
2017-08-30

Of the 28 recalls from New Flyer Industries Ltd. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 19 (68%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–25 of 28

  • HighNHTSA·17V539000·2017-08-30

    New Flyer Transit Bus Seat Belt Buckle Recall

    New Flyer is recalling 2015-2017 transit buses because the driver's seat belt buckle may be stuck, preventing the belt from latching.

    Product
    NEW FLYER — NEW FLYER MD30, XD40, XN40, MD35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V130000·2017-03-01

    New Flyer Transit Buses Recalled for Front Axle Beam Cracks

    New Flyer is recalling 2,357 transit buses from 2005-2007 because front axle beams may crack and fail, risking loss of vehicle control.

    Product
    NEW FLYER — NEW FLYER GE40LF, D60LFR, D60LF, C35LF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V678000·2016-09-20

    New Flyer Recalls 2016 XN60 and XN40 Buses for CNG Defect

    New Flyer is recalling 38 model year 2016 XN60 and XN40 transit buses because a pressure relief device may fracture, releasing high-pressure gas and increasing fire risk.

    Product
    NEW FLYER — NEW FLYER XN60, XN40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V223000·2016-04-19

    New Flyer Transit Buses Recalled for Rear Door Software Defect

    New Flyer is recalling specific transit buses because a software defect may cause the rear door to open unexpectedly while the bus is moving, increasing injury risk.

    Product
    NEW FLYER — NEW FLYER XN40, XN60, C40LFR, XN35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V038000·2016-01-26

    New Flyer and NABI Buses Recalled for Seat Belt Anchor Defect

    New Flyer is recalling specific 2009-2015 New Flyer and NABI buses because missing welds on seat brackets could allow seat belts to separate during a crash.

    Product
    NEW FLYER — NEW FLYER, NABI XN40, XDE60, XD60, XD40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V562000·2015-09-04

    New Flyer Transit Buses Recalled for Potential Steering Loss

    New Flyer is recalling 432 transit buses from 2013-2015 because a tie rod clamp may be improperly torqued, risking a loss of steering.

    Product
    NEW FLYER — NEW FLYER XN40, XN35, XD40, XD60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V485000·2015-08-04

    New Flyer Recalls NABI Transit Buses Due to Pressure Relief Defect

    New Flyer is recalling specific 2014-2015 NABI transit buses because pressure relief devices may fail to vent gas, increasing the risk of tank explosion, fire, and injury.

    Product
    NABI — NABI 40LFW, 42BRT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V333000·2015-06-01

    New Flyer Transit Bus Recall for Door Software Defect

    New Flyer is recalling specific transit buses because a software defect may cause rear doors to open while the bus is moving.

    Product
    NEW FLYER — NEW FLYER XDE35, XN40, XN60, C40LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V292000·2015-05-18

    New Flyer Buses Recalled for Engine Vent Tube Fire Risk

    New Flyer is recalling certain 2008-2014 buses because a vent tube may detach, allowing engine oil to contact hot surfaces and increase fire risk.

    Product
    NEW FLYER — NEW FLYER C40LF, C40LFR, C35LF, C35LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V519000·2014-08-28

    New Flyer Recalls 2014 Transit Buses Due to Fuel Filter Defect

    New Flyer is recalling 2014 transit buses because a fuel filter defect may cause the engine to stall without warning, increasing the risk of a crash.

    Product
    NEW FLYER — NEW FLYER XDE60, XDE40, XD60, XD40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V087000·2014-03-04

    New Flyer Transit Buses Recalled for Potential Exhaust Fire Risk

    New Flyer is recalling certain transit buses because condensation in the intake manifold may freeze, causing sensor issues that could lead to exhaust flames or vehicle fires.

    Product
    NEW FLYER — NEW FLYER C40LF, C40LFR, C35LF, C35LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V487000·2013-10-17

    New Flyer Recalls 2013 Buses Due to Air Brake Line Installation Error

    New Flyer is recalling 119 model year 2013 buses because incorrectly installed air lines may cause a loss of service braking, increasing crash risk.

    Product
    NEW FLYER — NEW FLYER XD60, XN40, XDE40, XD40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V485000·2013-09-20

    New Flyer Recalls 2004-2006 D40I Buses Due to Fire Risk

    New Flyer is recalling 57 D40I transit buses from 2004-2006 because electrical components may conduct electricity and cause a fire.

    Product
    NEW FLYER — NEW FLYER D40I
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·13V459000·2013-09-20

    New Flyer Recalls 2012 XN40 Buses with Defective Bicycle Racks

    New Flyer is recalling 2012 XN40 transit buses because cracks in certain bicycle racks may cause parts to fall off, creating a road hazard.

    Product
    NEW FLYER — NEW FLYER XN40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·13V221000·2013-05-28

    New Flyer Transit Buses Recalled for Defective Push-to-Start Switches

    New Flyer is recalling certain 2012-2013 transit buses because a weak spring in the push-to-start switch may allow the engine to start unexpectedly, posing an injury risk to nearby workers.

    Product
    NEW FLYER — NEW FLYER XD40, XN40, XD35, XD60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V591000·2012-12-17

    New Flyer Transit Buses Recalled for Drive Shaft Access Panel Defect

    New Flyer is recalling 2,048 model year 2004-2011 transit buses because the drive shaft access panel may be insufficiently strong or secured, posing an injury risk if the drive shaft fails.

    Product
    NEW FLYER — NEW FLYER DE40LFR, DE40LFA, D40LFR, D60LF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V518000·2012-10-25

    New Flyer Recalls Transit Buses Due to Parking Brake Fire Risk

    New Flyer is recalling 2010-2012 transit buses because air pressure leaks may cause parking brakes to drag and overheat, potentially resulting in a fire.

    Product
    NEW FLYER — NEW FLYER XD35, XDE35, D40LFR, XDE40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V515000·2012-10-17

    New Flyer Recalls 2010 Transit Buses Due to Weak Emergency Window Handles

    New Flyer is recalling 2010 GE35LFR and GE40LFR transit buses because emergency egress window handles may break before releasing the latch, potentially trapping passengers.

    Product
    NEW FLYER — NEW FLYER GE40LFR, GE35LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V466000·2012-09-24

    New Flyer Recalls 2005-2006 C40LF and C40LFR Transit Buses

    New Flyer is recalling 163 transit buses due to a turbocharger defect that may cause engine damage, oil leaks, smoke, or fire.

    Product
    NEW FLYER — NEW FLYER C40LF, C40LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V132000·2012-03-26

    New Flyer XDE40 and XDE35 Buses Recalled for Battery Fire Risk

    New Flyer is recalling certain XDE40 and XDE35 transit buses because debris in the lithium-ion battery system can breach electrical isolation, increasing the risk of a fire.

    Product
    NEW FLYER — NEW FLYER XDE40, XDE35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V002000·2012-01-04

    New Flyer Transit Buses Recalled for Instrument Panel Software Defect

    New Flyer is recalling certain 2009-2012 transit buses because instrument panel software may prevent warning lights from illuminating, potentially causing engine shutdown and loss of propulsion.

    Product
    NEW FLYER — NEW FLYER XD40, XDE40, XD35, XDE35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11V431000·2011-08-22

    New Flyer Transit Buses Recalled for Exhaust Clamp Fire Risk

    New Flyer is recalling 78 heavy-duty transit buses equipped with Cummins diesel engines because a T-bolt in the exhaust clamp assembly can fracture, potentially causing a fire or road hazard.

    Product
    NEW FLYER — NEW FLYER DE40LFR, D40LFR, D35LFR, DE60LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11V407000·2011-08-05

    New Flyer Recalls 2005-2010 Buses for Driveshaft Bolt Failure Risk

    New Flyer is recalling certain 2005-2010 heavy-duty transit buses because retaining bolts on the propulsion system may fail, potentially causing the driveshaft to separate from the vehicle.

    Product
    NEW FLYER — NEW FLYER H40LFR, GE35LFR, GE40LF, GE40LFA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V605000·2010-11-29

    New Flyer Transit Buses Recalled for Missing Axle Welds

    New Flyer is recalling 522 heavy-duty transit buses from model years 2008-2009 because front axle radius rod brackets may be missing required welds, increasing crash risk.

    Product
    NEW FLYER — NEW FLYER D40LF, DE60LF, E40LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide