The Recall Desk

Manufacturer

Mack Trucks, Inc.

141 recalls in our database name Mack Trucks, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
141
Critical
0
Severe
87
Most recent
2026-10-01

Of the 141 recalls from Mack Trucks, Inc. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 87 (62%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

26–50 of 141

  • SevereNHTSA·25V026000·2025-01-21

    Mack Trucks Recalls 2024-2025 Pinnacle and Pioneer Models for Brake Defect

    Mack Trucks is recalling 2024-2025 Pinnacle and Pioneer trucks because air tanks have insufficient volume, potentially reducing braking performance and increasing crash risk.

    Product
    MACK — MACK PIONEER PR (4), PINNACLE (PI/PN)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V792000·2024-10-23

    Mack trucks with Bendix EC80 units may lose safety system functions

    Mack is recalling certain 2020-2025 trucks with Bendix EC80 Advanced Electronic Control Units because electrical noise may cause the ECU to misprocess commands or stop working.

    Product
    MACK — MACK GRANITE (GR), ANTHEM (AN), PINNACLE (PI/PN), PIONEER PR (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V773000·2024-10-18

    Mack Granite trucks recalled for non-DOT-tested tires

    Mack Trucks is recalling certain 2019–2025 Granite (GR) and 2018 Granite (GU) vehicles equipped with tires that may not have been DOT tested. The untested tires may fail, increasing crash risk.

    Product
    MACK — MACK GRANITE (GR), GRANITE (GU)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E065000·2024-08-05

    Mack Trucks Recalls Replacement Tie Rods With Defective Ball Studs

    Mack Trucks is recalling certain replacement tie rods equipped with USK ball studs that may break due to incorrect heat treatment, potentially causing loss of steering control.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V567000·2024-07-30

    Mack truck seat and belt anchorage bolts may be improperly tightened

    Mack is recalling certain 2024-2025 Anthem, Granite and Pinnacle vehicles with RollTek driver's seats because the seat pedestal and seat belt attachment may have been improperly tightened.

    Product
    MACK — MACK PINNACLE (PI/PN), ANTHEM (AN), PIONEER PR (4), GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V504000·2024-07-02

    Mack Trucks Recalls 2025 Models Due to Tie Rod Assembly Defect

    Mack Trucks is recalling 2025 LR, Granite, and Pinnacle vehicles because a tie rod assembly ball stud may fail, creating a road hazard and increasing crash risk.

    Product
    MACK — MACK PIONEER PR (4), GRANITE (GR), LR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V424000·2024-06-09

    Mack Trucks Recalls 2025 Anthem and Pinnacle Models for Steering Defect

    Mack Trucks is recalling 2025 Anthem and Pinnacle trucks because improperly heat-treated ball studs in the tie rod assemblies may fail, causing a sudden loss of steering control.

    Product
    MACK — MACK ANTHEM (AN), PIONEER PR (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V399000·2024-06-04

    Mack Recalls 2024 MD Electric Trucks for Battery Software Defect

    Mack Trucks is recalling 2024 MD Electric trucks because a battery software defect may cause sudden loss of steering and drive power, increasing crash risk.

    Product
    MACK — MACK MD (ELECTRIC)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V398000·2024-06-04

    Mack Trucks Recalls 2025 Models Due to Steering Control Loss Risk

    Mack Trucks is recalling 2025 AN, GR, and TE trucks because a defective drag link may cause sudden loss of steering control, increasing crash risk.

    Product
    MACK — MACK ANTHEM (AN), TE, GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V333000·2024-05-14

    Mack MD and Terrapro trucks recalled for incorrect weight rating

    Mack is recalling certain 2024-2025 MD and Terrapro vehicles because the Gross Axle Weight Rating (GAWR) on the certification label is incorrect, allowing vehicles to be overloaded and increasing crash risk. Dealers will replace the label free of charge.

    Product
    MACK — MACK TERRAPRO (TE), MD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V122000·2024-02-19

    2024 Mack Granite trucks recalled for insufficient air brake tank volume

    Mack Trucks is recalling certain 2022–2024 Granite vehicles because the air tanks do not have sufficient volume for the brake system, reducing braking performance and increasing crash risk.

    Product
    MACK — MACK GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V899000·2023-12-26

    2024 Mack Commercial Trucks Steering Gear Assembly Defect Recall

    Mack is recalling approximately 284 certain 2024 Pinnacle, Anthem, and Terrapro commercial trucks with incorrectly assembled steering gear assemblies that could cause loss of steering control and increase crash risk. Dealers will inspect and replace defective gears free of charge.

    Product
    MACK — MACK ANTHEM (AN), PINNACLE (PI/PN), TERRAPRO (TE)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V887000·2023-12-22

    Mack Trucks Recalls 2024 Granite Vehicles for Steering Knuckle Defect

    Mack Trucks is recalling 2024 Granite vehicles because bearing journals may not be fully seated in the steering knuckle assembly, which can lead to axle spindle fracture and increased crash risk.

    Product
    MACK — MACK GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V792000·2023-11-22

    Mack Trucks Recalled for Accelerator Control System Sensor Failure

    Mack is recalling 650 2023–2024 trucks due to a sensor defect that can prevent the engine from returning to idle quickly, risking loss of vehicle control. The company will replace the throttle pedal and update software at no cost.

    Product
    MACK — MACK ANTHEM (AN), GRANITE (GR), LR, TERRAPRO (TE)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V746000·2023-11-07

    Mack Recalls 2024 MD Trucks Due to Steering Wheel Bolt Issue

    Mack Trucks is recalling 2024 MD trucks because the steering wheel attachment bolt may loosen and separate, potentially causing the steering wheel to detach.

    Product
    MACK — MACK MD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V713000·2023-10-24

    Mack Recalls 2024 LR Trucks Due to Loose Steering Fasteners

    Mack Trucks is recalling 2024 LR vehicles because loose steering fasteners may cause loss of control. Owners should not drive until repaired.

    Product
    MACK — MACK LR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V600000·2023-08-25

    2015-2023 Mack Granite trucks recalled for incorrect turn signal positioning

    Mack is recalling certain 2015-2023 GRANITE trucks because turn signals may be positioned incorrectly, reducing visibility. This could prevent other drivers from seeing when the vehicle is turning, increasing crash risk.

    Product
    MACK — MACK GRANITE (GU), GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V513000·2023-07-27

    Mack Recalls 2024 LR Garbage Trucks Due to Missing Floor Welds

    Mack Trucks is recalling 2024 LR garbage trucks because missing floor welds may reduce strength, potentially allowing the passenger seat pedestal to buckle in a crash.

    Product
    MACK — MACK LR
    Category
    Vehicle
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Mack Trucks

American company

Country
United States
Founded
1900
Parent company
Volvo Trucks

Official website

Source: Wikidata (Q950650), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.