42 recalls in our database name International Motors, LLC as the manufacturing or recalling firm.

What the numbers show

Total
42
Critical
0
Severe
27
Most recent
2026-08-06

Of the 42 recalls from International Motors, LLC we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 27 (64%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–25 of 42

  • HighNHTSA·26V516000·2026-08-06

    International Recalls 2027 Trucks Due to Wiper Nut Loosening Risk

    International is recalling 2027 HV, HX, LT, MV, and RH trucks because a wiper nut may loosen, causing wipers to disconnect and reducing visibility.

    Product
    INTERNATIONAL — INTERNATIONAL HX, LT, RH, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V460000·2026-07-16

    IC Bus EVSB and CESB school buses recalled for structural body joint defects

    International Motors, LLC is recalling certain 2025-2027 IC Bus EVSB and CESB school buses due to insufficient epoxy coverage on body joints. This defect may cause panels to separate during a crash.

    Product
    IC BUS — IC BUS CESB, EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V459000·2026-07-16

    2023–2027 International MV and HV vehicles battery cable fire risk

    International Motors is recalling certain 2021, 2023–2027 MV and 2026–2027 HV vehicles. The battery interconnect cable may contact adjacent components, creating a short circuit that increases fire risk.

    Product
    INTERNATIONAL — INTERNATIONAL HV, MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V382000·2026-06-11

    International Recalls 2026-2027 HV Trucks for Brake Release Delay

    International is recalling 2026-2027 HV vehicles because the service brake may take longer than expected to release, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V348000·2026-05-28

    IC Bus Recalls 2026-2027 EVSB School Buses for Drive Motor Bolt Issue

    International Motors is recalling 2026-2027 IC Bus EVSB school buses because improperly tightened bolts may allow the drive motor to detach, creating a road hazard.

    Product
    IC BUS — IC BUS EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V294000·2026-05-11

    International Recalls 2026-2027 HV Trucks for Brake Release Delay

    International is recalling 2026-2027 HV vehicles because the service brake may take longer than expected to release, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V226000·2026-04-09

    IC Bus Recalls EVSB School Buses Due to High Voltage Switch Defect

    International Motors is recalling 2022-2027 IC Bus EVSB school buses because a high voltage disconnect switch may fail to shut off power, posing a risk of electrical shock.

    Product
    IC BUS — IC BUS EVSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V168000·2026-03-19

    IC Bus school bus body joints may lack sufficient epoxy coverage

    International is recalling certain 2023-2027 IC Bus CESB and 2025-2027 IC Bus EVSB school buses because the body panel joint may have been attached without sufficient epoxy coverage.

    Product
    IC BUS — IC BUS EVSB, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V111000·2026-02-26

    IC Bus school bus brake lines may be damaged and leak

    International is recalling certain 2023-2027 IC Bus CESB school buses because the brake lines may have been installed with incorrect hardware, which can damage the lines and cause a leak.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V084000·2026-02-12

    International truck software may fail to brake with adaptive cruise

    International is recalling certain 2026-2027 MV vehicles because the ECU software may fail to engage the brakes when adaptive cruise control or hill hold assist is in use.

    Product
    INTERNATIONAL — INTERNATIONAL MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V817000·2025-11-25

    International truck control units can lose ABS and stability control

    International is recalling certain 2016-2026 trucks with Bendix control units because electrical noise may cause the ECU to misprocess commands or stop working, disabling ABS and stability control.

    Product
    INTERNATIONAL — INTERNATIONAL 8600, HV, HX, LONESTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V806000·2025-11-20

    International trucks may stay in gear with the parking brake applied

    International is recalling certain 2023-2026 LT and RH vehicles because the auto neutral function may not recognise that the parking brake has been applied, leaving the transmission in gear.

    Product
    INTERNATIONAL — INTERNATIONAL RH, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V781000·2025-11-13

    Trucks recalled because a clogged valve can keep the brakes engaged

    International Motors is recalling 1,303 model year 2023-2026 LT and 2024-2025 RH trucks because a clogged Hill Start Assist exhaust port may delay or prevent release of the service brakes.

    Product
    INTERNATIONAL — INTERNATIONAL RH, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V783000·2025-11-13

    School buses recalled because the weight rating may be exceeded when full

    International Motors is recalling 142 model year 2023-2027 IC Bus CESB school buses because the bus may exceed its Gross Vehicle Weight Rating when fully occupied with full tanks.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V763000·2025-11-06

    International Recalls 2019-2020 CV Vehicles Due to Brake Harness Defect

    International is recalling 2019-2020 CV vehicles because a brake pressure switch harness may lack protective material, potentially causing a short circuit and reduced brake performance.

    Product
    INTERNATIONAL — INTERNATIONAL CV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V646000·2025-09-25

    School bus tire can damage air line activating the parking brake

    International is recalling certain 2024-2026 IC Bus CESB school buses because a tire may contact and damage the air dryer discharge line, causing an air leak that unintentionally applies the parking brake.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V647000·2025-09-25

    International Recalls 2025-2026 IC Bus CECB Due to Parking Brake Defect

    International is recalling 2025-2026 IC Bus CECB commercial buses because a tire may damage an air line, causing the parking brake to activate unintentionally while driving.

    Product
    IC BUS — IC BUS CECB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V641000·2025-09-25

    International Recalls 2026 IC Bus CECB for Wiper Crank Shaft Defect

    International is recalling 2026 IC Bus CECB commercial buses because a weld on the wiper crank shaft may fail, causing the left-side wiper to stop working.

    Product
    IC BUS — IC BUS CECB
    Category
    Vehicle
    Distribution
    Distributed nationwide