The Recall Desk

Manufacturer

General Motors, LLC

498 recalls in our database name General Motors, LLC as the manufacturing or recalling firm.

What the numbers show

Total
498
Critical
3
Severe
257
Most recent
2026-10-21

Of the 498 recalls from General Motors, LLC we have scored against our rubric, 3 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 257 (52%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

76–100 of 498

  • SevereNHTSA·24V487000·2024-06-28

    Chevrolet Blazer EV front control arm may fracture causing control loss

    General Motors is recalling certain 2024 Chevrolet Blazer EV vehicles because the right front lower control arm may contain a manufacturing defect that can cause it to fracture.

    Product
    CHEVROLET — CHEVROLET BLAZER EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V481000·2024-06-27

    Chevrolet Bolt battery diagnostic software may miss defective modules

    GM is recalling certain 2020-2022 Bolt EV and 2022 Bolt EUV vehicles previously remedied under 21V-650, because diagnostic software may have been installed incorrectly and fail to detect defective battery modules.

    Product
    CHEVROLET — CHEVROLET BOLT EUV, BOLT EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V459000·2024-06-20

    Cadillac XT5 and XT6 instrument panels may not illuminate signal reminders

    GM is recalling certain 2023-2025 Cadillac XT5 and XT6 vehicles because the instrument panel may not illuminate when hazard warning lights, high beams or turn signals are activated.

    Product
    CADILLAC — CADILLAC XT5, XT6
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V366000·2024-05-23

    Chevrolet Colorado fitted with tires that do not match the label

    GM is recalling certain 2024 Chevrolet Colorado vehicles because incorrect tires may have been installed that do not match the tire label, and the TPMS may report inaccurately.

    Product
    CHEVROLET — CHEVROLET COLORADO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V320000·2024-05-09

    General Motors Recalls 2024 Electric Vehicles for Rear Drive Unit Fault

    GM is recalling 2024 Cadillac Lyriq and related vehicles due to faulty rear drive wiring that can cause loss of power and increase crash risk.

    Product
    GMC — GMC, CHEVROLET, CADILLAC HUMMER EV PICKUP, SILVERADO EV, BLAZER EV, LYRIQ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V311000·2024-05-02

    2024 Cadillac XT5 Driver Airbag May Fail to Deploy During Crash

    General Motors is recalling 2024 Cadillac XT5 vehicles because the driver's front airbag cushion may tear during deployment, preventing proper airbag operation. A non-deploying airbag increases the risk of injury in a crash.

    Product
    CADILLAC — CADILLAC XT5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V237000·2024-03-28

    Chevrolet Colorado and GMC Canyon front wheel hub bolts may break

    General Motors is recalling certain 2023 Chevrolet Colorado and GMC Canyon vehicles because front wheel hub bolts may have been over-tightened and damaged during installation.

    Product
    CHEVROLET — CHEVROLET, GMC COLORADO, CANYON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V133000·2024-02-22

    Chevrolet Colorado and GMC Canyon may brake automatically without an obstacle

    GM is recalling certain 2023 Chevrolet Colorado and GMC Canyon vehicles because the front camera module may falsely detect an obstacle and engage automatic emergency braking unexpectedly.

    Product
    CHEVROLET — CHEVROLET, GMC COLORADO, CANYON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V087000·2024-02-08

    2024 Chevrolet Silverado EV seat belt bezel defect may impair restraint

    GM is recalling 338 2024 Chevrolet Silverado EV vehicles due to an incorrect second-row center seat belt bezel that may damage or tear the seat belt in a crash, potentially failing to restrain occupants.

    Product
    CHEVROLET — CHEVROLET SILVERADO EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24E009000·2024-02-08

    GM Recalls Autoliv Driver Front Air Bags for 2011-2012 Chevrolet Models

    General Motors is recalling Autoliv driver front air bags sold as service replacement parts for 2011-2012 Chevrolet Silverado 1500, Suburban, and Tahoe vehicles due to a manufacturing defect.

    Product
    AIR BAGS:FRONTAL recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V060000·2024-02-01

    General Motors Recalls Pickup Trucks with Defective Power Tailgate Latches

    General Motors is recalling certain 2020-2024 Chevrolet Silverado and GMC Sierra pickup trucks due to faulty electronic tailgate switches that may inadvertently unlatch while the vehicle is parked. The defect can allow the tailgate to open while driving, potentially causing cargo loss and creating a road hazard.

    Product
    GMC — GMC, CHEVROLET SIERRA 3500, SILVERADO 2500, SILVERADO 3500, SIERRA 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V014000·2024-01-11

    GM Recalls 2022 BrightDrop EV600 Vehicles Due to Fire Risk

    General Motors is recalling 2022 BrightDrop EV600 vehicles because the front-drive unit may leak oil, creating a risk of engine compartment fire.

    Product
    BRIGHTDROP — BRIGHTDROP EV600
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V870000·2023-12-21

    GM Recalls 2014 Buick Verano and Chevrolet Cruze for Air Bag Defect

    General Motors is recalling 2014 Buick Verano and Chevrolet Cruze vehicles because side roof-rail air bag inflators may rupture, posing an injury risk.

    Product
    CHEVROLET — CHEVROLET, BUICK CRUZE, VERANO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V869000·2023-12-21

    2024 Chevrolet Equinox door strikers may fracture and open unexpectedly

    General Motors is recalling certain 2024 Chevrolet Equinox and related models because door strikers may fracture, potentially causing doors to open unexpectedly while driving.

    Product
    CHEVROLET — CHEVROLET, GMC BLAZER, EQUINOX, TERRAIN, BLAZER EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V845000·2023-12-14

    2019 Chevrolet Bolt EV Fire Hazard After Crash

    General Motors is recalling certain 2017-2023 Chevrolet Bolt EV vehicles where the seat belt pretensioner exhaust may ignite carpet fibers near the B-pillar following a crash, creating a fire risk.

    Product
    CHEVROLET — CHEVROLET BOLT EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V786000·2023-11-22

    2024 Chevrolet Silverado EV Front Seat Belt Buckle Bolts May Not Be Properly Tightened

    General Motors recalls certain 2024 Chevrolet Silverado EV vehicles due to improperly tightened front seat belt buckle attachment bolts that may not restrain occupants properly during a crash.

    Product
    GMC — GMC, CHEVROLET HUMMER EV SUV, HUMMER EV PICKUP, SILVERADO EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V785000·2023-11-22

    Cadillac Lyriq seat belt bracket defect recall for 2023-2024 models

    General Motors is recalling certain 2023-2024 Cadillac Lyriq vehicles because the bracket anchoring the rear seat belts may have been improperly welded. The defect may prevent the seat belts from properly restraining occupants during a crash.

    Product
    CADILLAC — CADILLAC LYRIQ, redundant LYRIQ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V744000·2023-11-06

    2024 Buick Envista Software Update: Instrument Panel Display Blanking Issue

    General Motors recalls certain 2024 Buick Envista vehicles for a software defect that may cause the instrument panel display to go blank, preventing visibility of critical safety information like vehicle speed and warning lights.

    Product
    BUICK — BUICK, CHEVROLET ENCORE GX, TRAX, ENVISTA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V683000·2023-10-12

    GM Recalls 2023-2024 BrightDrop Zevo 600 for Air Bag Deployment Issue

    General Motors is recalling 2023-2024 BrightDrop Zevo 600 vehicles with optional passenger jump seats due to a trim panel that may interfere with the right-side roof-rail air bag.

    Product
    BRIGHTDROP — BRIGHTDROP ZEVO 600
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V682000·2023-10-12

    2023 Cadillac Lyriq Pedestrian Warning Sounds May Not Activate

    General Motors is recalling certain 2023 Cadillac Lyriq vehicles due to a software defect in the body control module. The pedestrian warning sounds may fail to activate, creating a crash risk.

    Product
    CADILLAC — CADILLAC LYRIQ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V681000·2023-10-12

    GMC Acadia and Cadillac Windshield Detachment Risk Recall

    General Motors is recalling 2023 GMC Acadia vehicles and certain 2024 Cadillac models due to windshields that may not be properly bonded to the vehicle body. A detached windshield during a crash could increase the risk of injury.

    Product
    GMC — GMC, CADILLAC ACADIA, XT6, XT5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V642000·2023-09-20

    2023 Chevrolet Tahoe and Related Models Suspension Bolt Recall

    General Motors is recalling certain 2023 Tahoe, Suburban, Escalade, Escalade ESV, Yukon, and Yukon XL vehicles due to improperly heat-treated rear suspension bolts that may break, risking wheel misalignment and crash.

    Product
    CADILLAC — CADILLAC, CHEVROLET, GMC ESCALADE ESV, SUBURBAN, TAHOE, YUKON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V674000·2023-09-20

    GM Recalls 2014 Buick Verano and Chevrolet Cruze for Air Bag Defect

    General Motors is recalling 2014 Buick Verano and Chevrolet Cruze vehicles because side roof-rail air bag inflators may rupture, potentially causing injury from metal fragments.

    Product
    CHEVROLET — CHEVROLET, BUICK CRUZE, VERANO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23E065000·2023-08-31

    GM Recalls Webasto Portable Charging Cords Due to Grounding Defect

    General Motors is recalling specific Webasto portable charging cords that may fail to stop charging if the ground connection is lost, posing an electric shock risk.

    Product
    EQUIPMENT:ELECTRICAL recall
    Category
    Vehicle
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

General Motors

American multinational automotive company

Country
United States
Founded
1908

Official website