The Recall Desk

Hazard

Loss Of Power recalls

197 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
197
Critical
1
Severe
137
Most recent
2026-08-13

Of the 197 loss of power recalls we have scored against our rubric, 1 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 137 (70%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all loss of power recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

26–50 of 197

  • SevereNHTSA·25V710000·2025-10-17

    Jeep Wrangler 4XE software update can cause loss of drive power

    Chrysler is recalling certain 2023-2025 Jeep Wrangler 4XE plug-in hybrids because a software error in an over-the-air update may result in a loss of drive power. The remedy is still under development.

    Product
    JEEP — JEEP WRANGLER 4XE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V669000·2025-10-07

    2024-2026 LUCID AIR Vehicles Recalled for Drive Shaft Defect

    Lucid USA is recalling 225 2024-2026 LUCID AIR vehicles with Pure Rear-Wheel Drive due to improperly secured bolts that could cause the half-shaft to disconnect, increasing crash risk.

    Product
    LUCID — LUCID AIR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V598000·2025-09-11

    Motorcycles recalled because water in the throttle control can cause power loss

    KTM North America is recalling certain Husqvarna Svartpilen 401, Vitpilen 401 and KTM 390 Adventure motorcycles because water could enter the e-throttle control unit and cause loss of drive power. 9,070 units are affected.

    Product
    HUSQVARNA — HUSQVARNA, KTM SVARTPILEN 401, VITPILEN 401, 390 ADVENTURE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V587000·2025-09-09

    Zero Motorcycles Recalls 2023-2024 Models Due to Wiring Defect

    Zero Motorcycles is recalling 2023-2024 DSR, DSR/X, DS, and DSRP models because improperly routed wires may break, causing a loss of drive power and increasing crash risk.

    Product
    ZERO — ZERO DS, DSR, DSR/X, DSRP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V549000·2025-08-25

    2025–2026 Hyundai Tucson and Santa Fe Engine Fastener Recall

    Hyundai is recalling certain 2025–2026 Tucson and Santa Fe vehicles because engine connecting rod bolts may have been improperly tightened, risking loss of drive power, engine damage, oil leaks, and potential fire.

    Product
    HYUNDAI — HYUNDAI SANTA FE, TUCSON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V548000·2025-08-25

    Kia K4 and Sorento connecting rod bolts may be improperly tightened

    Kia is recalling certain 2025 K4 and Sorento vehicles because the connecting rod bolts in the engine may have been improperly tightened, which can cause a loss of drive power.

    Product
    KIA — KIA K4, SORENTO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V537000·2025-08-21

    Rivian high voltage distribution box grounding can cause power loss

    Rivian is recalling certain 2025 R1S and R1T vehicles because an improperly grounded connection inside the High Voltage Distribution Box may cause a loss of drive power.

    Product
    RIVIAN — RIVIAN R1S, R1T
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V487000·2025-07-25

    Mercedes EQB battery bus bar screws can cause sudden power loss

    Mercedes-Benz is recalling certain 2022-2023 EQB 300 and EQB 350 4MATIC vehicles because the high voltage battery bus bar may be secured with incorrect screws, causing a sudden loss of drive power.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ EQB 300 4MATIC, EQB 350 4MATIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V395000·2025-07-23

    BMW electric drive motor software can shut down high voltage system

    BMW is recalling certain 2022-2025 i4, 2022-2024 iX, 2023-2024 i7 and 2024 i5 vehicles because electric drive motor software may shut down the high-voltage system, causing a loss of drive power.

    Product
    BMW — BMW I5, IX, I4, I7
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V481000·2025-07-23

    Tiffin motorhome alternator programming error can stall the engine

    Tiffin is recalling certain 2023-2026 motorhomes with 2.0 litre engines because the secondary alternator controller programming was not properly updated, which can stall the engine.

    Product
    TIFFIN — TIFFIN GH1, GT1, CONVOY, GH2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V470000·2025-07-16

    BMW electric vehicle battery modules may be improperly assembled

    BMW is recalling certain 2022-2025 iX, 2023-2024 i7 and 2022-2023 i4 vehicles because high-voltage battery cell modules may not have been assembled properly, stressing the module frame.

    Product
    BMW — BMW I4, I7, IX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V376000·2025-07-07

    Kawasaki Ninja ZX-6R Motorcycles Engine Crankshaft Bushing Recall

    Kawasaki is recalling certain 2024–2025 Ninja ZX-6R motorcycles because the engine may lose power during operation due to crankshaft bushing seizure, increasing crash risk.

    Product
    KAWASAKI — KAWASAKI NINJA ZX-6R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V372000·2025-06-03

    2025 Ford Escape Cylinder Head Defect Causes Oil Leaks

    Ford is recalling 2023-2025 Escape and 2025 Bronco Sport vehicles with defective cylinder heads that may cause oil leaks, loss of drive power, and fire risk.

    Product
    FORD — FORD ESCAPE, BRONCO SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V349000·2025-05-23

    Lincoln Aviator plug-in hybrid battery cells can short internally

    Ford is recalling certain 2020-2021 Lincoln Aviator PHEV vehicles previously repaired under 23V626, because a manufacturing defect in high voltage battery cells may cause an internal short circuit.

    Product
    LINCOLN — LINCOLN AVIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V319000·2025-05-16

    Isuzu Recalls 2025 NRR EV Due to Electrical Overheating Risk

    Isuzu is recalling 2025 NRR EV vehicles because a gap in the electrical system may cause overheating and loss of drive power, increasing crash risk.

    Product
    ISUZU — ISUZU NRR EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V275000·2025-04-24

    2025 Can-Am Origin and Pulse Electric Motorcycle Battery Recall

    NHTSA is recalling 2025 Can-Am Origin and Pulse electric motorcycles because a faulty breather valve may allow water into the battery, risking fire or loss of power.

    Product
    CAN-AM — CAN-AM ORIGIN, PULSE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1570-2025·2025-04-23

    HeartMate Mobile Power Unit electrical malfunction may cause loss of power

    Thoratec LLC is recalling HeartMate Mobile Power Units due to an electrical component defect that may prevent the unit from turning on, cause unprompted shut down, or trigger false alarms. If power is lost and not switched to rechargeable batteries within 15 minutes, the connected pump may lose power.

    Product
    HeartMate Mobile Power Unit: REF: 107754, NA; 107758, EU; 107758AU, AU; 107758UK, UK; L107758, EU Rental. Used with HeartMate 3 and II Left Ventricular Assist System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V261000·2025-04-18

    Motiv Recalls F-53 and F-59 Chassis Due to Bracket Failure Risk

    Motiv Power Systems is recalling 2019-2022 F-53 and F-59 chassis vehicles because a support bracket may break, causing an electrical short and loss of drive power.

    Product
    MOTIV — MOTIV F-59 BEV CHASSIS, F-53 BEV CHASSIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V181000·2025-03-24

    Peterbilt and Kenworth high voltage contactors can open cutting drive power

    PACCAR is recalling certain 2021-2025 Peterbilt 520, 579 and Kenworth T680 trucks because the high voltage contactors may open, causing a sudden loss of high voltage and drive power.

    Product
    KENWORTH — KENWORTH, PETERBILT T680, 579, 520
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V130000·2025-02-28

    Ford Recalls 2021-2022 Mustang Mach-E for Battery Contactor Overheating Risk

    Ford is recalling 2021-2022 Mustang Mach-E vehicles previously repaired under recall 22V-412 because high voltage battery contactors may overheat, potentially causing loss of drive power and increasing crash risk.

    Product
    FORD — FORD MUSTANG MACH E
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V127000·2025-02-28

    Ford Maverick control modules may miss a low 12-volt battery

    Ford is recalling certain 2022 Maverick vehicles previously repaired under 24V-590, because the body and powertrain control modules may fail to detect a change in 12-volt battery state of charge.

    Product
    FORD — FORD MAVERICK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V125000·2025-02-28

    Audi Q4 e-tron on-board charger failure can cut drive power

    Volkswagen is recalling certain 2024-2025 Audi Q4 e-Tron and 2024 ID.4 vehicles because the on-board charger may fail and stop charging the 12-volt battery, causing a loss of drive power.

    Product
    AUDI — AUDI, VOLKSWAGEN Q4 E-TRON, Q4 SPORTBACK E-TRON, ID.4
    Category
    Vehicle
    Distribution
    Distributed nationwide