168 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
168
Critical
1
Severe
32
Most recent
2026-08-13

Of the 168 fire hazard recalls we have scored against our rubric, 1 (1%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 32 (19%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all fire hazard recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

51–75 of 168

  • HighFDA (Devices)·Z-2214-2025·2025-08-06

    Philips MR 7700 gradient coils may act as a heat source

    MR 7700 systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 82 units are affected.

    Product
    MR 7700 Model Numbers (REF): (1) 782120, (2) 782153;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2215-2025·2025-08-06

    SmartPath to dStream 3.0T gradient coils may act as heat source

    SmartPath to dStream for 3.0T systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 15 units affected.

    Product
    SmartPath to dStream for 3.0T Model Number (REF): 782145;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereCPSC·25396·2025-07-24

    Rechargeable electric bug zapper rackets can catch fire during extended use

    Electric Bug Zapper Racket fly and mosquito swatters, model BZ-001, are being recalled because the rechargeable battery can catch fire when used for extended periods. About 29,000 units affected.

    Product
    Rechargeable Electric Bug Zapper Racket, Fly Swatter, and Mosquito Swatter for Indoor and Outdoor use
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·25395·2025-07-24

    Frigidaire branded minifridges can short circuit and ignite their plastic housing

    Curtis International minifridges sold under the Frigidaire name are being recalled because internal electrical components can short circuit and ignite the housing. About 634,000 units are affected.

    Product
    Frigidaire-brand Minifridges, models EFMIS129, EFMIS137, EFMIS149 and EFMIS175, limited to the listed serial numbers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·25403·2025-07-24

    FENGQS F7 Pro e-bike batteries can overheat and ignite

    FENGQS F7 Pro e-bikes with batteries made on April 21, 2024 are being recalled because the lithium-ion battery can overheat and ignite. Thirteen ignitions and two fires have been reported.

    Product
    FENGQS F7 Pro E-bikes
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·25390·2025-07-17

    iStore magnetic wireless power banks can overheat and ignite while charging

    iStore Magnetic Wireless Power Banks, model IST-09991/W05, are being recalled because the lithium-ion battery can overheat and ignite while charging. Three incidents and about $15,000 in property damage reported.

    Product
    iStore Magnetic Wireless Power Banks (IST-09991/W05 model only)
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·25391·2025-07-17

    VIVI e-bike lithium-ion batteries can overheat, posing fire and burn hazards

    36-volt lithium-ion batteries supplied with certain VIVI e-bikes are being recalled because they can overheat. Fourteen overheating incidents including three fires have been reported. About 24,000 units affected.

    Product
    36-volt lithium-ion batteries used with VIVI E-bikes
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1921-2025·2025-06-18

    SOLTIVE Premium SuperPulsed Laser System surgical instrument thermal incident

    Olympus is recalling the SOLTIVE Premium SuperPulsed Laser System due to risk of thermal incidents including smoke, sparks, burning, or flames during clinical use caused by fiber fracturing.

    Product
    Brand Name: Powered Laser Surgical Instrument Product Name: SOLTIVE Premium SuperPulsed Laser System Model/Catalog Number: TFL-PLS, TFL-PLS-JA (Japan only); Software Version: N/A Product Description: SOLTIVE Laser Systems use technology to increase procedural efficiency and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V390000·2025-06-12

    Chevrolet Silverado medium duty brake pressure switches may short and overheat

    GM is recalling certain 2019-2024 Chevrolet Silverado Medium Duty trucks because the brake pressure sensor may leak fluid into the switch and short circuit. Owners are told to park outside.

    Product
    CHEVROLET — CHEVROLET SILVERADO 4500, SILVERADO 6500, 6500, SILVERADO 5500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V306000·2025-05-09

    Ford Super Duty fuel return line connectors may crack and leak

    Ford is recalling certain F-250 and F-350 vehicles because cracked fuel return line connectors may leak fuel into the engine compartment. Five units are affected.

    Product
    FORD — FORD F-350 SD, F-250 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1560-2025·2025-04-23

    Welch Allyn CP150 Electrocardiograph Recall Due to Battery Fire Risk

    Baxter Healthcare is recalling Welch Allyn CP150 Electrocardiographs worldwide due to reports of battery-related fires. The fires occurred when devices used non-approved, third-party aftermarket batteries.

    Product
    Welch Allyn CP150 Electrocardiograph:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25V165000·2025-03-14

    Ford Escape fuel injector repair under earlier recalls was incorrect

    Ford is recalling certain Escape and Bronco Sport vehicles previously repaired incorrectly under recalls 22V-859 or 24V-187, because a fuel injector may crack and leak fuel.

    Product
    FORD — FORD ESCAPE, BRONCO SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V151000·2025-03-11

    Keystone travel trailer wiring lacks sufficient surge protection

    Keystone RV is recalling certain 2025 Kodiak, Colorado and Sunset travel trailers because the 7-way cord and 12-volt distribution box were wired with insufficient surge protection.

    Product
    KEYSTONE — KEYSTONE KODIAK, COLORADO, SUNSET TRAIL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V080000·2025-02-12

    Audi Q5 and A7 high voltage batteries may overheat

    Volkswagen is recalling certain 2021-2024 Audi Q5 and 2022 A7 e plug-in hybrid vehicles because the high-voltage battery may overheat, increasing the risk of a fire.

    Product
    AUDI — AUDI Q5, A7 E
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V954000·2024-12-20

    Ford Escape high voltage battery cells may short circuit internally

    Ford is recalling certain 2020-2024 Escape and 2021-2024 Lincoln Corsair vehicles because a manufacturing defect in high voltage battery cells may cause an internal short circuit.

    Product
    FORD — FORD, LINCOLN ESCAPE, CORSAIR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V851000·2024-12-20

    Ford F-150 misaligned engine cup plugs may cause rapid oil leaks

    Ford is recalling certain 2024-2025 F-150, 2024 Expedition and Lincoln Navigator vehicles with 3.5L GTDI engines because a misaligned engine cup plug can cause a rapid oil leak.

    Product
    LINCOLN — LINCOLN, FORD NAVIGATOR, EXPEDITION, F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V950000·2024-12-19

    Acura TLX fuel filler necks and tanks may be improperly welded

    Acura is recalling certain 2021-2023 TLX vehicles because the fuel filler neck and fuel tank may have been improperly welded, which can result in a fuel leak.

    Product
    ACURA — ACURA TLX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0466-2025·2024-11-27

    Smiths Medical CADD-Solis AC adapter input plugs pose electrical shock risk

    Smiths Medical is recalling 156,400 CADD-Solis AC adapters due to damaged or broken input plugs that may expose metal contacts. The affected adapters could pose a risk of electrical shock or fire.

    Product
    smiths medical CADD-Solis Li-ion Rechargeable Battery Packs AC adapter, Model Number REF 21-0270-25, for use with the CADD-Solis infusion pumps
    Category
    Medical Device
    Distribution
    0 states
  • HighNHTSA·24V876000·2024-11-20

    Oliver travel trailer water heater burner brackets may loosen and misdirect flame

    Oliver Travel Trailers is recalling certain 2016-2024 Elite I and Elite II trailers because the Truma water heater burner bracket may loosen, misdirecting the flame.

    Product
    OLIVER TRAVEL TRAILERS — OLIVER TRAVEL TRAILERS LEGACY ELITE, LEGACY ELITE II
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0210-2025·2024-10-30

    Baxter TruSystem 7000 Operating Tables: Battery Short-Circuits, Smoke Risk

    Baxter Healthcare is recalling 6,045 TruSystem 7000 U operating tables worldwide due to battery and connector failures that can cause electrical short-circuits and emit smoke.

    Product
    Baxter Operating table TruSystem 7000 U (MB), Product codes: a) REF 1604786; b) REF 1604788; c) REF 1723633
    Category
    Medical Device
    Distribution
    0 states
  • HighNHTSA·24V803000·2024-10-25

    Palomino axle equalizer may contact and damage the LP gas manifold

    Forest River is recalling certain 2025 Palomino recreational vehicles because the axle equalizer may contact and damage the LP gas manifold, causing a propane leak.

    Product
    FOREST RIVER — FOREST RIVER PALOMINO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0090-2025·2024-10-23

    Leica Biosystems Cryostat Model CM3050 S lacks warning label for flammable sprays

    Leica cryostat units lack a warning about flammable freezing sprays that can ignite in the chamber. The company discovered through post-market surveillance that users were applying these flammable sprays without being warned of the fire hazard.

    Product
    Leica Biosystems Cryostat Model Number CM3050 S, Material Numbers: a) 14047033518, b) 14903050S01, c) 14903050S02, d) 14903050S03; for freezing and sectioning tissue samples
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V785000·2024-10-21

    Triumph alternator harness wiring may short circuit and overheat

    Triumph is recalling certain 2022-2024 Bonneville and Scrambler motorcycles because the wiring between the alternator and main harness connector may short circuit and overheat.

    Product
    TRIUMPH — TRIUMPH STREET SCRAMBLER SANDSTOR, BONNEVILLE T120 BLACK, BONNEVILLE T100, BONNEVILLE T120
    Category
    Vehicle
    Distribution
    Distributed nationwide