The Recall Desk

Hazard

Brake Fluid Leak recalls

56 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
56
Critical
0
Severe
43
Most recent
2025-12-17

Of the 56 brake fluid leak recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 43 (77%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all brake fluid leak recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 56

  • SevereNHTSA·25V873000·2025-12-17

    Suzuki Recalls 2025-2026 DR-Z400 Motorcycles for Brake Fluid Leak Risk

    Suzuki is recalling 2025-2026 DR-Z400S and 2025 DR-Z400SM motorcycles because incorrectly tightened screws may allow brake fluid to leak, reducing braking ability.

    Product
    SUZUKI — SUZUKI DR-Z400SM, DR-Z400S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V550000·2025-08-26

    Forest River Riverstone hydraulic brake lines can fail and leak

    Forest River is recalling certain 2018-2026 Riverstone fifth wheel trailers because the steel hydraulic brake lines may fail and leak brake fluid, causing a loss of brake function.

    Product
    FOREST RIVER — FOREST RIVER RIVERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V503000·2025-08-06

    IC Bus CESB School Buses Brake Pressure Switch Fire Risk Recall

    International Motors is recalling certain 2016–2024 IC Bus CESB school buses because the brake pressure switch assembly may leak brake fluid into electrical components, causing a short circuit and fire risk while driving or parked.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V502000·2025-08-06

    2018–2025 International and IC Bus vehicles recalled for fire risk

    International Motors is recalling certain 2018–2025 International 4000 Series, MV, 1300 FBC, and IC Bus TC and CECB vehicles. A leaking brake pressure switch assembly may cause an electrical short circuit that increases fire risk while driving or parked.

    Product
    IC BUS — IC BUS, INTERNATIONAL CECB, MV, 1300FBC, 4000 SERIES 4300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V438000·2025-06-27

    Ford Recalls 2025 F-150 Lightning BEV Due to Brake Hose Bracket Issue

    Ford is recalling 2025 F-150 Lightning BEV vehicles because front brake jounce hose bracket screws may loosen, causing a brake fluid leak that increases stopping distance.

    Product
    FORD — FORD F-150 LIGHTNING BEV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V414000·2025-06-25

    International CV brake pressure sensor can leak fluid causing fire

    International is recalling certain 2019-2025 CV vehicles because the brake pressure sensor assembly may leak brake fluid into the pressure switch and short circuit. Owners are advised to park outside until repaired.

    Product
    INTERNATIONAL — INTERNATIONAL CV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V390000·2025-06-12

    Chevrolet Silverado medium duty brake pressure switches may short and overheat

    GM is recalling certain 2019-2024 Chevrolet Silverado Medium Duty trucks because the brake pressure sensor may leak fluid into the switch and short circuit. Owners are told to park outside.

    Product
    CHEVROLET — CHEVROLET SILVERADO 4500, SILVERADO 6500, 6500, SILVERADO 5500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V314000·2025-05-09

    Ford Expedition front brake lines may contact the air cleaner pipe

    Ford is recalling certain 2022-2024 Expedition and Lincoln Navigator vehicles because front brake lines may contact the engine air cleaner outlet pipe and leak brake fluid.

    Product
    FORD — FORD, LINCOLN EXPEDITION, NAVIGATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V116000·2025-02-24

    Mercedes-Benz Recalls S-Class Vehicles Due to Front Brake Hose Rupture Risk

    Mercedes-Benz is recalling 2021-2023 S-Class and Maybach vehicles because front brake hoses may rupture and leak fluid, increasing stopping distance and crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, MERCEDES-MAYBACH S 500, S 500 4MATIC, S 580, S 580 4MATIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V058000·2025-02-06

    2025 Toyota Tacoma Rear Brake Hoses Subject to Fluid Leak Risk

    Toyota is recalling certain 2024–2025 Tacoma 4-wheel drive vehicles because rear brake hoses can be damaged by mud and dirt buildup, causing brake fluid leaks that reduce braking ability and increase crash risk.

    Product
    TOYOTA — TOYOTA TACOMA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V911000·2024-12-05

    2025 Lexus NX recalled for loose brake caliper and wheel bearing bolts

    Toyota is recalling 2025 Lexus NX vehicles with loose brake caliper and wheel bearing bolts that may cause brake fluid leaks or wheel detachment. Either condition increases the risk of a crash.

    Product
    TOYOTA — TOYOTA, LEXUS RAV4, NX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V753000·2024-10-09

    Harley-Davidson FXLRST and FXRST Motorcycles Recalled for Brake Line Damage

    Certain 2022-2024 Harley-Davidson FXLRST and 2022 FXRST motorcycles have brake lines that may contact the fuel tank and become damaged, risking loss of front brake function.

    Product
    HARLEY-DAVIDSON — HARLEY-DAVIDSON FXLRST, FXRST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V394000·2024-06-03

    2024 Ford Mustang Clutch Pressure Line May Contact Hot Exhaust

    Ford is recalling certain 2024 Mustang vehicles because the clutch pressure line may be improperly secured and contact hot exhaust, risking loss of drive power and fire.

    Product
    FORD — FORD MUSTANG
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V120000·2024-02-19

    2023–2024 Horton Ford Emergency Vehicles Brake Line Recall

    Halcore Group, Inc. is recalling certain 2023–2024 Horton emergency vehicles built on Ford F-450, F-550, and F-600 chassis because the left rear brake line can contact and be damaged by the strut mount when the rear suspension is lowered, risking brake fluid leakage and loss of brakes.

    Product
    HORTON — HORTON FORD F-450, FORD F-600, FORD F-550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V791000·2023-11-22

    2021 Nissan Rogue rear brake calipers may leak fluid

    Certain 2021 Nissan Rogue vehicles may have missing internal bushings in rear brake calipers, allowing brake fluid to leak and reduce braking performance.

    Product
    NISSAN — NISSAN ROGUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V672000·2023-10-04

    2023 Harley-Davidson FLTRXSE Motorcycles Recalled for Brake Line Defect

    Harley-Davidson is recalling 2023 FLTRXSE and FLHXSE motorcycles due to improperly secured rear brake line clamps. The brake line may chafe against the exhaust pipe, causing fluid leaks that reduce braking ability.

    Product
    HARLEY-DAVIDSON — HARLEY-DAVIDSON FLTRXSE, FLHXSE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V430000·2023-06-15

    2023 Honda Civic recalled for brake modulator fluid leak

    Honda recalls 2023 Civic vehicles with a defective brake modulator that may leak fluid, potentially causing unintended vehicle movement or increased brake pedal travel.

    Product
    HONDA — HONDA, ACURA ACCORD, INTEGRA, RDX, CIVIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·22781·2022-09-29

    Yamaha Viking Off-Road Side-by-Side Vehicles Recalled for Brake Hazards

    Yamaha is recalling about 330 Model Year 2022 Viking Off-Road Side-by-Side vehicles because improperly installed rear brake lines can leak brake fluid and reduce vehicle control, creating crash and injury hazards.

    Product
    Yamaha Viking Off-Road Side-by-Side vehicles
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V718000·2022-09-26

    2023 Volkswagen Atlas Models Recalled for Brake Line Leaks

    Volkswagen is recalling 2023 Atlas and Atlas Cross Sport models due to brake lines that may leak at threaded connections. A brake fluid leak can increase stopping distance, raising crash risk.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS CROSS SPORT, ATLAS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V364000·2022-05-20

    GM Recalls 2022 Chevrolet HD Trucks for Brake Fluid Leak Risk

    General Motors is recalling 2022 Chevrolet 4500HD, 5500HD, and 6500HD trucks because a brake line fitting may leak fluid, increasing stopping distance.

    Product
    CHEVROLET — CHEVROLET 6500HD, 5500HD, 4500HD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V355000·2022-05-19

    2022 International CV Vehicles Brake Sensor Fitting May Cause Brake Failure

    Navistar is recalling certain 2022 International CV vehicles because the pressure sensor fitting on the brake line assembly may not be tightened correctly, potentially causing brake fluid loss and brake failure.

    Product
    INTERNATIONAL — INTERNATIONAL CV
    Category
    Vehicle
    Distribution
    Distributed nationwide