Vehicle recalls in our database all come from NHTSA. They cover passenger cars, light trucks, SUVs, motorcycles, tires, child safety seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA Campaign Number (a string like 25V123000) and lists every make / model / year combination affected. We carry the full vehicle range so you can search by your own car.

The most common vehicle-recall categories are airbag and seatbelt failures (the consequence is non-deployment in a crash), fuel system defects with fire risk, steering or brake malfunctions, electrical defects in EVs that can cause battery thermal events, software bugs in driver-assist systems, and child-seat harness failures. Recalls for tires almost always relate to a tread-separation risk in a defined production date range.

Every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, with no expiration. If your vehicle has an open recall, your dealer is required to perform the remedy free of charge as long as the vehicle exists. If you're not sure whether your vehicle is affected, the VIN lookup decodes your specific vehicle and cross-references the NHTSA database directly.

1701–1725 of 15584

  • SevereNHTSA·25V135000·2025-02-28

    Mercedes Sprinter parking brake bracket welds can fail causing rollaway

    Daimler Vans is recalling certain 2024 Mercedes-Benz Sprinter vehicles because the parking brake cable bracket welds may fail and disengage the parking brake, failing FMVSS 105.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SPRINTER 2500, SPRINTER 1500, SPRINTER 4500, SPRINTER 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V133000·2025-02-28

    Ford hybrids can shift into neutral unexpectedly losing drive power

    Ford is recalling certain 2022-2024 Maverick, 2022 Escape and 2021-2022 Lincoln Corsair vehicles previously repaired under 24V-330, because hybrid powertrain software may shift the vehicle into neutral unexpectedly.

    Product
    FORD — FORD, LINCOLN MAVERICK, ESCAPE, CORSAIR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V134000·2025-02-28

    Ford Super Duty rearview image may not show with hitch assist

    Ford is recalling certain 2023 F-Super Duty F-250, F-350 and F-450 vehicles previously repaired under 23V-573, because the default rearview camera image may not display when using Pro Trailer Hitch Assist.

    Product
    FORD — FORD F-350 SD, F-250 SD, F-450 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V123000·2025-02-28

    Ford Maverick Hybrid instrument cluster may not illuminate warning lights

    Ford is recalling certain 2022-2023 Maverick Hybrid vehicles previously repaired under 24V-140, because the instrument panel cluster may not properly illuminate warning lights or gauges.

    Product
    FORD — FORD MAVERICK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V136000·2025-02-28

    Big Tex Recalls 2025 Trailers Due to Undersized Winch Hardware

    Big Tex Trailer Manufacturing is recalling 2025 14RB, 14RD, 16RB, and 16RD trailers because undersized winch hardware may allow the winch to detach, creating a road hazard.

    Product
    BIG TEX — BIG TEX 16RB, 14RD, 14RB, 16RD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V124000·2025-02-28

    Ford Maverick brake lights can illuminate without the driver braking

    Ford is recalling certain 2022 Maverick vehicles previously repaired under 24V-730, because the ABS module may illuminate the brake lights when the driver is not braking. This fails FMVSS 108.

    Product
    FORD — FORD MAVERICK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V121000·2025-02-27

    Motorhome exhaust tips can detach letting fumes into the cabin

    REV Recreation Group is recalling certain 2022-2025 Fleetwood and Holiday Rambler motorhomes because the engine exhaust tip may detach, allowing exhaust fumes to enter the cabin.

    Product
    FLEETWOOD — FLEETWOOD, HOLIDAY RAMBLER SOUTHWIND, INVICTA, ADMIRAL, VACATIONER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V122000·2025-02-27

    Orange EV Recalls HUSK-E Trucks Due to Incorrect Weight Rating Placard

    Orange EV is recalling 2023-2024 HUSK-E XP terminal trucks because the rear weight rating placard is incorrect and tires may be inadequate, increasing crash risk.

    Product
    ORANGE EV — ORANGE EV HUSK-E
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V120000·2025-02-27

    Volkswagen and Audi electric vehicles may not display gear position indicator

    Volkswagen is recalling certain 2021-2023 ID.4 and 2022-2023 Audi Q4 e-Tron vehicles because the instrument panel may not properly display the transmission gear lever indicator, failing FMVSS 102.

    Product
    VOLKSWAGEN — VOLKSWAGEN, AUDI ID.4, Q4 E-TRON, Q4 SPORTBACK E-TRON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V116000·2025-02-24

    Mercedes-Benz Recalls S-Class Vehicles Due to Front Brake Hose Rupture Risk

    Mercedes-Benz is recalling 2021-2023 S-Class and Maybach vehicles because front brake hoses may rupture and leak fluid, increasing stopping distance and crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, MERCEDES-MAYBACH S 500, S 500 4MATIC, S 580, S 580 4MATIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V115000·2025-02-24

    Kia EV9 rear drive unit motor shaft may be improperly welded

    Kia is recalling certain 2025 EV9 vehicles because the rear gear drive unit motor shaft may have been improperly welded and become damaged, causing a loss of drive power.

    Product
    KIA — KIA EV9
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25E013000·2025-02-24

    Joyson Recalls Side Curtain Air Bag Inflator Due to Detachment Risk

    Joyson is recalling one side curtain air bag inflator because the ignition holder may detach during deployment, creating a projectile hazard.

    Product
    AIR BAGS:SIDE/WINDOW:CURTAIN:INFLATOR recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V117000·2025-02-24

    Textron Recalls Cushman and E-Z-GO LSVs for Defective Reflectors

    Textron is recalling 2024-2025 Cushman and E-Z-GO low-speed vehicles because side and rear reflectors do not meet federal safety standards, increasing crash risk.

    Product
    CUSHMAN — CUSHMAN, E-Z-GO TOUR LSV, LIBERTY LSV, HAULER PRO LSV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V114000·2025-02-21

    Spartan RV chassis fuel filter hose can separate causing leak and stall

    Shyft Group is recalling certain 2022-2025 Spartan RV Chassis K2 vehicles with Cummins L9 diesel engines because the remote fuel filter hose may separate from the fitting.

    Product
    SPARTAN — SPARTAN K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V109000·2025-02-21

    BMW X3 battery cable connection can overheat stalling the engine

    BMW is recalling certain 2025 X3 30 xDrive vehicles because the connection between the positive battery cable and the starter-generator may be improperly tightened and overheat.

    Product
    BMW — BMW X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·25V111000·2025-02-21

    Forest River trailer weight rating placard may exceed safety chain rating

    Forest River is recalling certain 2017-2025 Coachmen Catalina, 2020-2025 Aurora and 2025 Puma travel trailers because the Gross Vehicle Weight Rating on the Federal placard may exceed the safety chain rating.

    Product
    FOREST RIVER — FOREST RIVER, COACHMEN AURORA, CATALINA, PUMA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V106000·2025-02-20

    BMW X3 rear door locks can be released with one motion

    BMW is recalling certain 2022-2024 X3 sDrive30i and xDrive30i vehicles because second-row door locking modules may allow the doors to be unlocked with a single motion, failing FMVSS 206.

    Product
    BMW — BMW X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·25141·2025-02-20

    Kubota Utility Tractors Recalled for Clutch Cable Failure and Crash Risk

    Kubota is recalling approximately 2,600 MX5400DTC utility tractors due to clutch cable failure that can reduce braking power, creating a crash hazard. No injuries have been reported to date.

    Product
    Kubota Utility Tractors model MX5400DTC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·25144·2025-02-20

    Triumph TF250-X Motorcycles Recalled for Electrical Short Circuits and Unintended Starting

    About 690 Triumph TF250-X motorcycles are recalled due to plastic switch cubes that crack when exposed to brake fluid, creating electrical short circuits that can cause the motorcycle to start unexpectedly. No injuries have been reported.

    Product
    Triumph TF250-X Closed Course Competition Motorcycles
    Category
    Vehicle
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.