The Recall Desk

Category

Vehicle recalls

NHTSA recalls of passenger vehicles, motorcycles, tires, and child seats.

About vehicle recalls

Vehicle recalls in our database all come from NHTSA. They cover passenger cars, light trucks, SUVs, motorcycles, tires, child safety seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA Campaign Number (a string like 25V123000) and lists every make / model / year combination affected. We carry the full vehicle range so you can search by your own car.

The most common vehicle-recall categories are airbag and seatbelt failures (the consequence is non-deployment in a crash), fuel system defects with fire risk, steering or brake malfunctions, electrical defects in EVs that can cause battery thermal events, software bugs in driver-assist systems, and child-seat harness failures. Recalls for tires almost always relate to a tread-separation risk in a defined production date range.

Every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, with no expiration. If your vehicle has an open recall, your dealer is required to perform the remedy free of charge as long as the vehicle exists. If you're not sure whether your vehicle is affected, the VIN lookup decodes your specific vehicle and cross-references the NHTSA database directly.

2626–2650 of 15584

  • HighNHTSA·24E032000·2024-04-12

    Ford Recalls Bronco Sport Hood Scoops Due to Detachment Risk

    Ford is recalling certain Bronco Sport hood scoops that may detach while driving, posing a risk of windshield damage or road hazards.

    Product
    STRUCTURE:BODY:HOOD recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V263000·2024-04-11

    Keystone Recalls 2024 Trailers Due to Axle Frame Contact Risk

    Keystone RV is recalling 214 specific 2024 trailer models because the suspension equalizer may allow the axle to contact the frame, increasing crash risk.

    Product
    KEYSTONE — KEYSTONE, DUTCHMEN HAMPTON, RETREAT, ASPEN TRAIL LOFT, RESIDENCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V260000·2024-04-11

    2022-2024 Tiffin Motorhomes Cooktop Circuit Board Fire Risk

    Tiffin Motorhomes is recalling certain 2022-2024 Allegro RED 360 and related motorhomes because the LED backlight circuit board in the cooktop may overheat, increasing fire risk. No fires or injuries have been reported.

    Product
    TIFFIN — TIFFIN BYWAY, ALLEGRO OPEN ROAD, ALLEGRO RED 360
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24196·2024-04-11

    Intimidator and Mahindra Utility Vehicles Recalled for Brake Line Failure Hazard

    About 19,264 Intimidator and Mahindra UTVs are recalled because the universal joint can fail and sever the brake line, posing a crash hazard. No injuries have been reported. Owners should immediately stop using the vehicles and contact a dealer for free repair.

    Product
    Intimidator and Mahindra branded utility vehicles (UTVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V258000·2024-04-10

    Hi-Tech E.V.S. Recalls 2020-2023 Spartan Fire Trucks for Wiring Defect

    Hi-Tech E.V.S. is recalling 2020-2023 Spartan Gladiator and Metrostar fire trucks because a firmware defect in specific nodes may cause electrical circuits to overheat and increase the risk of fire.

    Product
    HI-TECH E.V.S. — HI-TECH E.V.S. SPARTAN METROSTAR, SPARTAN GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V253000·2024-04-05

    Forest River Recalls Transit Buses Due to Unsecured Brake Lines

    Forest River Bus is recalling specific 2018-2024 transit bus models because unsecured brake lines may be damaged by the frame rail, increasing crash risk.

    Product
    STARCRAFT BUS — STARCRAFT BUS, ELDORADO, ELKHART SENATOR II, CANDIDATE II, ADVANTAGE, ALLSTAR MVP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V080000·2024-04-05

    Autocar Recalls 2023 Xpeditor and Xspotter Vehicles for Steering Defect

    Autocar is recalling 2023 Xpeditor and Xspotter vehicles because steering gears may have fewer recirculating balls than required, risking loss of steering control.

    Product
    AUTOCAR — AUTOCAR XSPOTTER, XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V254000·2024-04-05

    2024 Coachmen Catalina and Aurora Travel Trailers: Electrical Fire Risk

    Forest River is recalling certain 2024 Coachmen Catalina and Aurora Travel Trailers due to improper routing of the distribution panel wire. The unprotected wire increases the risk of fire.

    Product
    FOREST RIVER — FOREST RIVER, COACHMEN AURORA, CATALINA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V255000·2024-04-05

    Aston Martin DBX electrical cable defect may cause engine stall

    Aston Martin is recalling 2021-2024 DBX vehicles due to loose electrical cables in the battery fuse box, which may cause engine stall, loss of headlights, or loss of power steering, increasing crash risk.

    Product
    ASTON MARTIN — ASTON MARTIN DBX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V252000·2024-04-04

    Terex Advance Recalls 2023 Commander Vehicles for Steering Defect

    Terex Advance is recalling 2023 Commander vehicles because steering components may not be installed correctly, increasing the risk of a crash.

    Product
    TEREX ADVANCE — TEREX ADVANCE COMMANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V248000·2024-04-03

    Aston Martin Recalls 2021 DBX Vehicles for Loose Driveline Fasteners

    Aston Martin is recalling 2021 DBX vehicles because loose fasteners on the front propeller shaft and differential may cause loss of front wheel drive or engine stall.

    Product
    ASTON MARTIN — ASTON MARTIN DBX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V249000·2024-04-03

    2023-2024 Aston Martin DBX Oil Cooler Hoses May Burst

    Aston Martin is recalling certain 2023-2024 DBX707 vehicles because oil cooler hoses may burst, causing sudden oil loss that could lead to engine failure and fire.

    Product
    ASTON MARTIN — ASTON MARTIN DBX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V251000·2024-04-03

    Audi vehicles may have deactivated front passenger airbags

    Volkswagen is recalling certain 2023-2024 Audi models because an electrical connection in the front passenger occupant detection system may loosen, disabling the front passenger airbag and preventing deployment during a crash.

    Product
    AUDI — AUDI Q8, RS Q8, Q5, S5 CABRIOLET
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V247000·2024-04-03

    Winnebago Recalls 2024 Access Trailers Due to GFCI Wiring Defect

    Winnebago is recalling 2024 Access travel trailers because incorrectly wired GFCI outlets may lack protection, increasing the risk of electrical shock.

    Product
    WINNEBAGO — WINNEBAGO ACCESS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24E031000·2024-04-03

    Watson & Chalin Recalls SL2065 Steerable Lift Axle Suspension Systems

    Watson & Chalin is recalling SL2065 steerable lift axle suspension systems because bearing journals may not be fully seated, creating a risk of spindle fracture and crash.

    Product
    STEERING:LINKAGES:KNUCKLE:SPINDLE:ARM recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V245000·2024-04-02

    2021 Jayco Redhawk motorhomes recalled for power steering connection defect

    Certain 2021 Jayco Redhawk motorhomes have a defective power steering connection that can cause sudden loss of power steering and brake assist, increasing crash risk. Dealers will replace the defective parts free of charge.

    Product
    JAYCO — JAYCO, ENTEGRA GREYHAWK, GREYHAWK PRESTIGE, REDHAWK, ESTEEM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V246000·2024-04-02

    2024 Hyundai Santa Fe rearview camera obstruction recall

    The rearview camera image may be obstructed by a trailer parking assist message, reducing rearward visibility and increasing crash risk. An over-the-air software update will fix the issue.

    Product
    HYUNDAI — HYUNDAI SANTA FE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V244000·2024-04-01

    2023 Kia Forte: Front Suspension Control Arm Failure Risk

    Kia recalls certain 2023 Forte vehicles because the right front lower control arm may be improperly welded and fail, risking sudden loss of steering control and crashes.

    Product
    KIA — KIA FORTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V243000·2024-03-29

    Big Tex Recalls 2024 Trailers Due to Brake Oil Leak Risk

    Big Tex Trailer Manufacturing is recalling 2024 25GN, 25PH, 3XGN, and 3XPH trailers because improperly installed oil seals may leak onto the brake system, increasing crash risk.

    Product
    BIG TEX — BIG TEX 25PH, 3XPH, 25GN, 3XGN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V238000·2024-03-28

    Chrysler minivan windshields may not be properly bonded to the vehicle

    Chrysler is recalling certain 2024 Pacifica and Voyager vehicles whose windshields may not have been properly bonded, allowing them to detach during a crash. This fails FMVSS 212.

    Product
    CHRYSLER — CHRYSLER VOYAGER, PACIFICA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V237000·2024-03-28

    Chevrolet Colorado and GMC Canyon front wheel hub bolts may break

    General Motors is recalling certain 2023 Chevrolet Colorado and GMC Canyon vehicles because front wheel hub bolts may have been over-tightened and damaged during installation.

    Product
    CHEVROLET — CHEVROLET, GMC COLORADO, CANYON
    Category
    Vehicle
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.