The Recall Desk

State

Vermont product recalls

72,992 recalls have nationwide distribution and so reach Vermont. 1,983 additional recalls listed Vermont specifically in their distribution scope.

What the numbers show

Total
1,983
Critical
199
Severe
409
Most recent
2026-09-02

Of the 1,983 recalls naming Vermont we have scored against our rubric, 199 (10%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 409 (21%) are Severe.

These figures cover only the 1,983 recalls whose distribution notice names Vermont specifically. The 72,992 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

8376–8400 of 74975

  • HighNHTSA·24V963000·2024-12-20

    Orange EV Recalls T-Series and e-TRIEVER Trucks for Reverse Light Obstruction

    Orange EV is recalling 2023-2024 e-TRIEVER and 2018-2023 T-Series trucks because beavertail frames may obstruct reverse lights, reducing visibility and increasing crash risk.

    Product
    ORANGE EV — ORANGE EV T-SERIES ELECTRIC TRUCK, E-TRIEVER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V957000·2024-12-20

    Ford Super Duty high pressure fuel pumps may fail from biodiesel deposits

    Ford is recalling certain 2020-2022 F-Super Duty trucks because biodiesel deposits may form on pump drivetrain rollers and lead to high pressure fuel pump failure.

    Product
    FORD — FORD F-650, F-450 SD, F-550 SD, F-250 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V964000·2024-12-20

    Orange EV Recalls Trucks with Obstructed Rear Lights

    Orange EV is recalling 148 electric trucks because frame extenders obstruct rear lights, increasing crash risk.

    Product
    ORANGE EV — ORANGE EV T-SERIES ELECTRIC TRUCK, HUSK-E, E-TRIEVER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V851000·2024-12-20

    Ford F-150 misaligned engine cup plugs may cause rapid oil leaks

    Ford is recalling certain 2024-2025 F-150, 2024 Expedition and Lincoln Navigator vehicles with 3.5L GTDI engines because a misaligned engine cup plug can cause a rapid oil leak.

    Product
    FORD — FORD, LINCOLN EXPEDITION, F-150, NAVIGATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·25071·2024-12-19

    SKIL 40V 5.0Ah Lithium-Ion Batteries Recalled for Fire and Burn Hazard

    SKIL 40V batteries sold from 2019–2024 can overheat, causing fires and burns. Chervon reports 100 thermal incidents, including 8 burn/smoke cases and 49 property damage claims.

    Product
    SKIL 40V 5.0 Ah Lithium-Ion Batteries
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V949000·2024-12-19

    Ford Recalls 2023-2024 F-150 Lightning Due to Control Arm Defect

    Ford is recalling 2023-2024 F-150 Lightning vehicles because a front control arm nut may not be tightened properly, risking loss of steering control.

    Product
    FORD — FORD F-150 LIGHTNING BEV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V943000·2024-12-19

    Alfa Romeo Giulia and Stelvio Brake Pedal Recall

    Chrysler is recalling 2019-2020 Alfa Romeo Giulia and Stelvio vehicles because the brake pedal may detach from the brake booster, increasing crash risk.

    Product
    ALFA ROMEO — ALFA ROMEO STELVIO, GIULIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E108000·2024-12-19

    Chrysler Recalls Mopar Anti-Lock Brake Control Units for Brake Pedal Detachment

    Chrysler is recalling specific Mopar anti-lock brake control units because a fastener may be improperly assembled, allowing the brake pedal to detach from the brake booster.

    Product
    SERVICE BRAKES, HYDRAULIC:PEDALS AND LINKAGES recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·25072·2024-12-19

    Charmast W1056 Power Banks Recalled for Fire and Burn Hazards

    Charmast W1056 power banks sold on Amazon.com from December 2018-September 2024 are recalled for lithium-ion battery fire and burn hazards. The company received 44 reports of overheating, ignition, or burns.

    Product
    Charmast power banks, model W1056
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V942000·2024-12-19

    Ram Recalls 2025 1500 Trucks Due to Headlight Software Defect

    Chrysler is recalling 2025 Ram 1500 trucks because incorrect headlight software may cause the lights to stop working, increasing crash risk.

    Product
    RAM — RAM 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V947000·2024-12-19

    Range Rover rearview cameras may admit water and distort the image

    Land Rover is recalling certain 2022-2023 Range Rover vehicles because water may enter the rearview camera, blanking or distorting the image. 11,961 units are affected.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V950000·2024-12-19

    Acura TLX fuel filler necks and tanks may be improperly welded

    Acura is recalling certain 2021-2023 TLX vehicles because the fuel filler neck and fuel tank may have been improperly welded, which can result in a fuel leak.

    Product
    ACURA — ACURA TLX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24E109000·2024-12-19

    Chrysler Recalls Mopar Rearview Camera Modules Due to Software Defect

    Chrysler is recalling specific Mopar rearview camera modules because incorrect software may prevent the image from displaying, increasing crash risk.

    Product
    BACK OVER PREVENTION:SOFTWARE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V944000·2024-12-19

    Jeep Wagoneer rearview camera modules carry incorrect software

    Chrysler is recalling certain 2024 Jeep Wagoneer, Grand Wagoneer, Grand Cherokee and Grand Cherokee L vehicles because incorrect camera module software may blank the rearview image.

    Product
    JEEP — JEEP GRAND CHEROKEE L, GRAND WAGONEER, GRAND CHEROKEE, WAGONEER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·25069·2024-12-19

    Elongdi Magnetic Building Sticks Sets Recalled for Ingestion Hazard

    Elongdi magnetic building stick sets sold on Amazon are recalled due to violation of federal toy magnet regulations. When swallowed, the high-powered magnets can attract each other and lodge in the digestive system, potentially causing serious internal injuries.

    Product
    Elongdi Magnetic Building Sticks Sets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·25070·2024-12-19

    Melii Baby Silicone Spoons Recalled for Choking Hazard

    Melii Baby silicone spoons for babies can break apart during use, creating a choking hazard. About 85,100 units sold through multiple retailers from April to August 2024 are affected; consumers should stop using them immediately.

    Product
    Silicone spoons for babies
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0664-2025·2024-12-18

    MICRO-X Rover Mobile X-ray System Exposure Timing Defect Recalled

    Micro-X Ltd. is recalling five MICRO-X Rover Mobile X-ray Systems due to a timing defect that prevents adequate X-ray exposures. The 4 millisecond exposure time does not allow sufficient tolerance for diagnostic-quality imaging.

    Product
    MICRO-X Rover Mobile X-ray System, # MXU-RV35
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V937000·2024-12-18

    2025 Chevrolet Silverado EV Pedestrian Alert System Sound Volume

    General Motors is recalling certain 2025 Chevrolet Silverado EV work trucks because the pedestrian alert sound system may not produce sound at sufficient volume. This increases the risk of pedestrians being unaware of an approaching vehicle.

    Product
    CHEVROLET — CHEVROLET SILVERADO EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0679-2025·2024-12-18

    Galaxy Bronchoscope Biopsy Tool Insertion Risk at Sharp Bend Angles

    Noah Medical is recalling Galaxy bronchoscope units due to risk that biopsy tools may require excessive force or fail to pass through the scope channel when the bronchoscope is sharply bent, potentially causing tissue injury or pneumothorax.

    Product
    Galaxy bronchoscope (Product GALB-001) used with Instructions for use, Part: 10000752, part of the Noah Medical Galaxy System (GAL-001)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V938000·2024-12-18

    Volvo Recalls 2023-2024 C40 Vehicles for Air Bag Clamp Defect

    Volvo is recalling 2023-2024 C40 vehicles because improperly crimped clamps may cause the driver's air bag to deploy improperly, increasing injury risk.

    Product
    VOLVO — VOLVO C40BEV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V939000·2024-12-18

    2024 Polestar 2 driver-side air bag module improper deployment

    Polestar is recalling certain 2024 Polestar 2 vehicles because clamps on the driver's side air bag module may be improperly crimped, causing the air bag to deploy improperly and reducing crash protection.

    Product
    POLESTAR — POLESTAR POLESTAR 2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V941000·2024-12-18

    2025 Mercedes-Benz E-Class vehicles recalled for rear axle carrier defect

    Mercedes-Benz is recalling 2025 E 350, E 350 4MATIC, E 450 4MATIC, and E 450 4MATIC station wagon vehicles due to an improperly welded camber strut bracket on the rear axle carrier that may separate and cause loss of vehicle handling and control.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ E 450 4MATIC ALL-TERRAIN, E 350, E 450 4MATIC, E 350 4MATIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0262-2025·2024-12-18

    Dietary supplement recalled for undeclared soy lecithin allergen

    DesBio lunaSOMM Natural Sleep Support Dietary Supplement is recalled due to undeclared soy lecithin. The product is labeled as containing sunflower lecithin but contains soy lecithin, posing a risk to consumers with soy allergies.

    Product
    DesBio lunaSOMM Natural Sleep Support Dietary Supplement capsules, 30 count in a Blue PET bottle with a White cap. Supplement facts declare Phosphatidylserine (from non-GMO sunflower lecithin powder) 40 mg. Distributed by Deseret Biologicals Inc 469 West Parkland Dr, Sandy, UT.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0127-2025·2024-12-18

    Levothyroxine sodium tablets recalled for potency failures nationwide

    Viatris Inc is recalling Levothyroxine Sodium 100 mcg tablets for potency failures causing some tablets to be too strong and others too weak. Approximately 65,169 units are affected nationwide.

    Product
    LEVOTHYROXINE SODIUM — LEVOTHYROXINE SODIUM (LEVOTHYROXINE SODIUM)
    Category
    Drug
    Distribution
    Distributed nationwide