  • HighCPSC·24098·2024-02-01

    Lovevery Slide & Seek Ball Runs Recalled for Choking Hazard

    Lovevery is recalling about 47,000 Slide & Seek Ball Runs with wooden knobs because the wooden knob can detach during or after shipping, posing a choking hazard to children. The product was sold online as part of the Babbler Play Kit from June 2023 through November 2023.

    Product
    Slide & Seek Ball Runs with Wooden Knobs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V065000·2024-02-01

    2023 Hyundai IONIQ 5 and IONIQ 6 driveshaft replacement recall

    Hyundai is recalling 2023 IONIQ 5, IONIQ 6, and Genesis GV60 vehicles for rear driveshafts that may break under load due to improper heat treatment, causing loss of drive power. Dealers will replace the driveshaft free of charge.

    Product
    HYUNDAI — HYUNDAI, GENESIS IONIQ 6, IONIQ 5, GV60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24100·2024-02-01

    Ekouaer Girl's Nightgowns Recalled for Fire and Burn Hazard

    Ekouaer girl's nightgowns fail to meet federal flammability standards for children's sleepwear, posing a risk of burn injuries. About 16,800 units sold on Amazon from May 2020 through July 2023 are affected.

    Product
    Ekouaer Girl's Nightgowns
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·24095·2024-02-01

    Snap Recalls Lithium-Ion Battery for Pixy Flying Cameras Due to Fire Hazard

    Snap is recalling about 71,000 rechargeable lithium-ion batteries sold with Pixy Flying Cameras because the battery can overheat and pose a fire hazard. The company has received four reports of battery overheating and bulging, including one minor battery fire and one minor injury.

    Product
    Lithium-ion battery sold for Pixy Flying Cameras
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V061000·2024-02-01

    Motorhome Seat Pedestal Weld Defect Causes Unsafe Seat Separation Risk

    Jayco is recalling certain 2020-2023 Entegra motorhomes because passenger seats may have improperly welded pedestals that can separate and cause the seat to loosen or detach.

    Product
    ENTEGRA — ENTEGRA REATTA XL, CORNERSTONE, ANTHEM, ASPIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V064000·2024-02-01

    Multiple Honda and Acura models recalled for defective airbag sensor

    Honda and Acura are recalling 750,114 vehicles from 2020-2022 model years. A defective front passenger seat weight sensor may fail to suppress the airbag, increasing the risk of injury in a crash.

    Product
    HONDA — HONDA, ACURA ACCORD, INSIGHT, CR-V, CIVIC TYPE R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·24104·2024-02-01

    NextGen Children's Bicycles Recalled for Safety Standard Violations

    Flat River Group is recalling about 22,700 NextGen children's bicycles because they do not meet federal safety standards. The bicycles lack required foot brakes, chain guards, or pedal reflectors, posing crash and injury hazards to children.

    Product
    NextGen Children's Bicycles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·24102·2024-02-01

    iFIT NordicTrack 50-Pound Adjustable Dumbbells Recalled for Impact Hazard

    iFIT is recalling NordicTrack 50-pound iSelect voice-controlled adjustable dumbbells because weight plates can dislodge during use, posing an impact hazard. Eight injuries including contusions and abrasions have been reported.

    Product
    NordicTrack 50 LB iSelect Voice-Controlled Adjustable Dumbbells
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V062000·2024-02-01

    Tiffin Allegro Bay motorhomes recalled for battery fire risk

    Tiffin is recalling certain 2022–2024 Allegro Bay motorhomes because batteries may shift during travel, causing electrical arcing and fire risk. Dealers will install new hold-down hardware at no charge.

    Product
    TIFFIN — TIFFIN ALLEGRO BAY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateCPSC·24105·2024-02-01

    Box Components Recalls BMX Race Bicycle Stems Due to Fall Hazard

    Box Components is recalling about 160 BMX Race Box One Oversized 31.8 Delta bicycle stems because the faceplate can crack and break, loosening handlebars and causing loss of control and crash injury risk. No injuries have been reported to date.

    Product
    BMX Race Box One Bicycle Stems
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • ModerateCPSC·24099·2024-02-01

    Meijer December Home Light Bulbs Recalled for Burst Hazard

    Meijer is recalling December Home branded candelabra-style light bulbs because some packages contain 3V bulbs instead of the labeled 120V versions. When a 3V bulb is used in a 120V fixture, it can burst, creating a laceration hazard.

    Product
    DECEMBER HOME® Replacement Light Bulbs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • ModerateCPSC·24106·2024-02-01

    Glass Little Wanderer Snow Globes Recalled for Laceration Hazard

    The Museum of Modern Art is recalling about 1,915 glass Little Wanderer snow globes sold at MoMA Design Stores because they can crack or fracture, posing a laceration hazard. No injuries have been reported.

    Product
    Snow globes (Little Wanderer)
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V059000·2024-01-31

    Vicinity Recalls 2017 Vi33 Buses Due to CNG Tank Clearance Issue

    Vicinity is recalling 2017 Vi33 transit buses because inadequate clearance may allow CNG tanks to contact mounting structures, potentially causing damage and gas leaks.

    Product
    VICINITY — VICINITY VI33
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0261-2024·2024-01-31

    Drug recall: Bleomycin injection vials recalled due to glass contamination

    Pfizer is recalling 3,546 vials of Bleomycin for Injection due to the presence of glass particulate matter. The affected lot was distributed nationwide in the USA, Netherlands, and Libya.

    Product
    BLEOMYCIN — BLEOMYCIN (BLEOMYCIN)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V056000·2024-01-31

    New Flyer Recalls Electric Buses Due to Battery Fire Risk

    New Flyer is recalling 337 electric buses because drain valve issues may allow liquid to accumulate in battery packs, increasing the risk of an electrical short and fire.

    Product
    NEW FLYER — NEW FLYER XE35, XE60, XHE40, XE40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V057000·2024-01-31

    Kia EV drive shafts can break under load causing power loss

    Kia is recalling certain 2023-2024 Niro EV and 2023 EV6 vehicles because an improperly heat-treated drive shaft can break under load, resulting in a loss of drive power.

    Product
    KIA — KIA NIRO EV, EV6
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0317-2024·2024-01-31

    Robitussin Honey CF Max Nighttime Adult Recalled for Microbial Contamination

    Haleon US Holdings LLC is recalling Robitussin Honey CF Max Nighttime Adult cough medicine due to microbial contamination. The FDA Class I recall affects 21,900 bottles distributed nationwide.

    Product
    Robitussin Honey CF Max Nighttime Adult (Acetaminophen 650 mg, Diphenhydramine HCl 25mg), 8 FL OZ (237 mL) bottle, Distributed by: GSK Consumer Healthcare, Warren, NJ 07059
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0316-2024·2024-01-31

    Robitussin Honey CF Max Non-Drowsy Adult recalled for microbial contamination

    GSK Consumer Healthcare recalls Robitussin Honey CF Max Non-Drowsy Adult due to microbial contamination in non-sterile products distributed nationwide. Affected lot numbers carry specific expiration dates.

    Product
    Robitussin Honey CF Max Non-Drowsy Adult (Acetaminophen 650mg, Dextromethorphan HBr 20 mg), a) 4 FL OZ (118mL) and b) 8 FL OZ (237 mL) bottles, Distributed by: GSK Consumer Healthcare, Warren, NJ 07059
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V058000·2024-01-31

    Heavy truck stability control software has incorrect axle spacing parameters

    Daimler Trucks is recalling certain 2024-2025 Western Star 49X and 2025 Freightliner Cascadia vehicles whose Electronic Stability Control software carries incorrect axle spacing parameters, failing FMVSS 136.

    Product
    WESTERN STAR — WESTERN STAR, FREIGHTLINER 49X, CASCADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0814-2024·2024-01-31

    TactiFlex Ablation Catheter Not Properly Recognized by EnSiteX EP System

    The TactiFlex Ablation Catheter is not correctly recognized by the EnSiteX EP System, which displays it as a different model, prevents certain features from appearing, and may show an inverted image.

    Product
    TactiFlex Ablation Sensor Enabled Ablation Catheter, Models A-TFSE-FJ, 7.5 F shaft and an 8F distal section, Sterile.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0772-2024·2024-01-31

    VITROS Anti-HBs Immunodiagnostic Products Recalled for Calibration Failures

    Ortho-Clinical Diagnostics is recalling VITROS Immunodiagnostic Products used to test for Hepatitis B antibodies due to potential calibration failures and falsely elevated test results affecting specific lot numbers.

    Product
    VITROS Immunodiagnostic Products Anti-HBs Quantitative Reagent Pack, Catalog No. 6801925 VITROS Immunodiagnostic Products Anti-HBs Calibrators, Catalog No. 6801926
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0786-2024·2024-01-31

    R&B Chocolate Chips Croissant Twist contains undeclared soy lecithin

    Lecoq Cuisine Corporation is recalling R&B Chocolate Chips Croissant Twist because the product contains undeclared soy lecithin. Consumers with soy allergies may be at risk if they consume this product.

    Product
    R&B Chocolate Chips Croissant Twist
    Category
    Food
    Distribution
    27 states
  • HighFDA (Devices)·Z-0782-2024·2024-01-31

    Hologic PANTHER FUSION System Recalled for Potential False Positive Flu B Results

    Hologic is recalling PANTHER FUSION nucleic acid testing systems due to the potential for false positive influenza B test results when a sample is also positive for SARS-CoV-2.

    Product
    PANTHER FUSION System REF 9121010000 The Panther System is an integrated nucleic acid testing system which fully automates all steps necessary to perform Aptima assays from sample processing through amplification, detection, and data reduction. The Panther Fusion System is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V055000·2024-01-31

    Motorhome retractable awnings can extend unintentionally during transit

    Jayco is recalling certain 2023 Entegra Expanse, Expanse LI, Jayco Solstice and Solstice LI motorhomes because the retractable awning may extend unintentionally while the vehicle is moving.

    Product
    JAYCO — JAYCO, ENTEGRA SOLSTICE, EXPANSE, EXPANSE LI, SOLSTICE LI
    Category
    Vehicle
    Distribution
    Distributed nationwide