The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

2201–2225 of 15382

  • HighNHTSA·24E050000·2024-06-21

    AROW Recalls MV210 Emergency Exit Windows Due to Latch Failure Risk

    AROW Global Corp is recalling MV210 emergency exit windows because the latch can fail during a crash, potentially allowing the window to open and increasing injury risk.

    Product
    STRUCTURE:EMERGENCY:ESCAPE/EGRESS/EXIT:LATCHING/RELEASE SYSTEM recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V462000·2024-06-20

    International truck tie rod ball studs were incorrectly heat treated

    Navistar is recalling certain 2025 International HV, LT, MV and RH trucks because tie rod ball studs may have been incorrectly heat-treated and can break. 116 units affected.

    Product
    INTERNATIONAL — INTERNATIONAL RH, HV, MV, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V463000·2024-06-20

    Navistar Recalls 2025 IC Bus CE School Buses for Tie Rod Defect

    Navistar is recalling 2025 IC Bus CE school buses because incorrectly heat-treated tie rod assemblies may break, potentially causing loss of steering control.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V465000·2024-06-20

    Audi e-tron GT front axle brake hoses may tear and leak

    Volkswagen is recalling certain 2022-2024 Audi RS e-tron GT and e-tron GT vehicles because the front axle brake hoses can develop tears, causing a leak and brake circuit failure.

    Product
    AUDI — AUDI E-TRON GT, RS E-TRON GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E051000·2024-06-20

    Hendrickson Lift Axle Suspension Recall for Tie Rod Assembly Defect

    Hendrickson is recalling 461 steerable lift axle suspension assemblies because the tie rod ball stud may fail, creating a road hazard.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V461000·2024-06-20

    Toyota Grand Highlander curtain airbags may deploy outside an open window

    Toyota is recalling certain 2024 Grand Highlander and Lexus TX vehicles because the side curtain airbags may not unroll as intended and could partially deploy outside an open window.

    Product
    TOYOTA — TOYOTA, LEXUS GRAND HIGHLANDER, TX, GRAND HIGHLANDER HYBRID, TX HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V466000·2024-06-20

    Fisker Ocean exterior door handles can stick and fail to open

    Fisker is recalling all 2023-2024 Ocean vehicles because the exterior door handles can stick and fail to open, which can prevent occupants from exiting in an emergency.

    Product
    FISKER — FISKER OCEAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V459000·2024-06-20

    Cadillac XT5 and XT6 instrument panels may not illuminate signal reminders

    GM is recalling certain 2023-2025 Cadillac XT5 and XT6 vehicles because the instrument panel may not illuminate when hazard warning lights, high beams or turn signals are activated.

    Product
    CADILLAC — CADILLAC XT5, XT6
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V464000·2024-06-20

    Volkswagen Atlas occupant detection wiring may deactivate the passenger airbag

    Volkswagen is recalling certain 2020-2024 Atlas and Atlas Cross Sport vehicles because a wiring fault in the passenger occupant detection system may deactivate the front passenger airbag.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS, ATLAS CROSS SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·24V458000·2024-06-20

    Rivian R1S and R1T tire placards show incorrect maximum capacity weight

    Rivian is recalling certain 2022-2023 R1S and R1T vehicles because the maximum vehicle capacity weight value on the tire placard label is incorrect, failing FMVSS 110.

    Product
    RIVIAN — RIVIAN R1T, R1S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V455000·2024-06-19

    2020–2025 Porsche Taycan front brake hoses can crack

    Porsche is recalling certain 2020–2025 Taycan vehicles because the front brake hoses can develop cracks and leak brake fluid, reducing braking performance. Dealers will replace the hoses for free.

    Product
    PORSCHE — PORSCHE TAYCAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V456000·2024-06-19

    2024 Tesla Cybertruck front windshield wiper motor failure recall

    Tesla is recalling certain 2024 Cybertruck vehicles due to excessive electrical current that can cause the front windshield wiper motor controller to fail, reducing visibility and increasing crash risk.

    Product
    TESLA — TESLA CYBERTRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·24V457000·2024-06-19

    2024 Tesla Cybertruck Trunk Bed Trim Sail Applique Recall

    Tesla is recalling certain 2024 Cybertruck vehicles because the trunk bed trim sail applique may be improperly adhered and can loosen or detach, creating a road hazard.

    Product
    TESLA — TESLA CYBERTRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V453000·2024-06-18

    Spartan Fire Recalls Gladiator and Metro Star Trucks for Brake Defect

    Spartan Fire is recalling 2017-2019 Gladiator and 2018-2019 Metro Star fire trucks because service brakes may engage slowly, increasing crash risk.

    Product
    SPARTAN FIRE — SPARTAN FIRE GLADIATOR, METROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V454000·2024-06-18

    Entrans Recalls 2017 Polar Tank ARJH Trailers Due to Weld Defect

    Entrans is recalling 2017 Polar Tank ARJH trailers because improper tank welding may cause leaks, creating a road hazard and increasing crash risk.

    Product
    POLAR TANK — POLAR TANK ARJH TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V452000·2024-06-18

    2022 Toyota Highlander Tires Insufficient Load Rating Safety Recall

    Southeast Toyota Distributors is recalling 2021–2024 Toyota Highlander vehicles due to 20-inch accessory tires with insufficient load ratings. Overloaded tires can fail and increase crash risk.

    Product
    TOYOTA — TOYOTA HIGHLANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V448000·2024-06-17

    Micro Bird Recalls G5 School Buses Due to Seat Attachment Defect

    Micro Bird is recalling 2011-2025 G5 school buses because certain seats may be improperly attached, increasing injury risk in a crash.

    Product
    MICRO BIRD — MICRO BIRD G5 SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V450000·2024-06-17

    2024 Land Rover Range Rover oil filter housing can crack and leak

    Jaguar Land Rover is recalling certain 2023–2024 Defender and 2024 Discovery, Range Rover, Range Rover Sport, and Range Rover Velar vehicles because the oil filter housing can crack and leak oil into the engine compartment, increasing the risk of fire.

    Product
    LAND ROVER — LAND ROVER DEFENDER, RANGE ROVER VELAR, DISCOVERY, RANGE ROVER SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V446000·2024-06-14

    Mercedes-Benz Recalls C 300 Vehicles Due to Wiring Fire Risk

    Mercedes-Benz is recalling 2022-2023 C 300 vehicles because an improperly tightened bolt on the pre-fuse box wire could cause overheating, leading to fire or loss of drive power.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ C 300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V443000·2024-06-14

    Ford Recalls 2021 F-150 Trucks Due to Disabled Reverse Lights

    Ford is recalling 2021 F-150 trucks with Onboard Scales because a software update may have disabled the reverse lights, increasing crash risk.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V442000·2024-06-14

    2023 Toyota Crown Rearview and Frontview Cameras May Separate

    Toyota is recalling certain 2023 Crown vehicles with defective rearview and frontview cameras that may separate and allow water infiltration, potentially failing to display images and reducing driver visibility.

    Product
    TOYOTA — TOYOTA CROWN
    Category
    Vehicle
    Distribution
    Distributed nationwide