The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1851–1875 of 15168

  • HighNHTSA·24V736000·2024-10-01

    2025 Daimler Trucks Fuel Pump Barrel Fracture Recall

    Daimler Trucks North America is recalling certain 2025 commercial trucks with Cummins fuel pumps that may fracture and leak fuel, potentially causing engine stall. No injuries have been reported.

    Product
    WESTERN STAR — WESTERN STAR, FREIGHTLINER, FCCC 49X, CASCADIA, XCM, XCP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V730000·2024-10-01

    Porsche Recalls 2025 Taycan for Delayed Rearview Camera Display

    Porsche is recalling 2025 Taycan vehicles because the rearview camera image may not display immediately when shifting into reverse, increasing crash risk.

    Product
    PORSCHE — PORSCHE TAYCAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V731000·2024-10-01

    2020-2023 Porsche Taycan Recalled for High-Voltage Battery Short Circuit Risk

    Porsche is recalling 2020-2023 Taycan vehicles due to a potential short circuit in the high-voltage battery that increases fire risk. Owners should limit charging to 80% until dealers replace the affected battery modules.

    Product
    PORSCHE — PORSCHE TAYCAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V729000·2024-10-01

    Ram 1500 Recalled for Turn Signal Self-Canceling Defect

    Chrysler is recalling 2023-2024 Ram 1500 vehicles because the turn signal self-canceling feature may not function properly, increasing crash risk.

    Product
    RAM — RAM 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V734000·2024-10-01

    2025 International HX and LT vehicles recalled for fuel pump fracture risk

    Navistar is recalling 2025 International HX and LT vehicles with Cummins X15 diesel engines due to fuel pump barrel fracture risk. The fracture can cause fuel leaks and engine stalls, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL HX, LT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V733000·2024-10-01

    Winnebago motorhomes recalled for defective turn signals

    Winnebago Industries recalls multiple motorhome models because turn signals may have insufficient lens area, making them difficult for other drivers to see and increasing crash risk. Dealers will replace the turn signals at no cost.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA VISTA, COMMERCIAL VEHICLE, SUNSTAR, SUNCRUISER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V727000·2024-09-30

    Nova Bus control unit software crash can cut drive power

    Nova Bus is recalling certain 2022-2023 LFS buses because a software error may cause the Vehicle Control Unit to crash, disconnecting the high voltage batteries and causing a loss of drive power.

    Product
    NOVA BUS — NOVA BUS LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V726000·2024-09-30

    Audi e-tron GT high voltage battery module can short circuit

    Audi is recalling certain 2022-2024 e-tron GT and RS e-tron GT vehicles because the high-voltage battery may experience a short circuit within the battery module, increasing fire risk.

    Product
    AUDI — AUDI RS E-TRON GT, E-TRON GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V720000·2024-09-27

    Jeep 4XE high voltage batteries can fail and catch fire

    Chrysler is recalling certain 2020-2024 Wrangler 4XE and 2022-2024 Grand Cherokee 4XE vehicles because the high voltage battery may fail internally and cause a fire while parked or driving.

    Product
    JEEP — JEEP GRAND CHEROKEE 4XE, WRANGLER 4XE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E080000·2024-09-27

    Chrysler Recalls Mopar Hybrid Service Kit Battery Packs Due to Fire Risk

    Chrysler is recalling specific Mopar Hybrid Service Kit Battery Packs because they may fail internally and cause a fire. Owners should park outside and not recharge until repaired.

    Product
    ELECTRICAL SYSTEM:PROPULSION SYSTEM:TRACTION BATTERY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V724000·2024-09-27

    Mercedes-Benz Recalls GLE 350 and GLE 450 for Air Bag Wiring Defect

    Mercedes-Benz is recalling 2021-2022 GLE 350 and GLE 450 vehicles because an incorrectly routed wiring harness may prevent front air bags from deploying properly.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLE 350, GLE 450
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V723000·2024-09-27

    Volkswagen Atlas brake master cylinder can block fluid port losing braking

    Volkswagen is recalling certain 2024 Atlas and Atlas Cross Sport vehicles because the brake master cylinder may have an incorrect secondary piston spring retainer that can block the brake fluid port.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS CROSS SPORT, ATLAS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V713000·2024-09-27

    Royal Enfield motorcycles have insufficient side and rear reflectors

    Royal Enfield is recalling certain 2023 Himalayan, Classic 350, Meteor 350, Hunter 350, Super Meteor 650, Int 650 and Continental GT 650 motorcycles whose side and rear reflectors fail FMVSS 108.

    Product
    ROYAL ENFIELD — ROYAL ENFIELD SUPER METEOR 650, CLASSIC 350, HIMALAYAN, HUNTER 350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V725000·2024-09-27

    Ford stripped chassis gear position indicator may not display properly

    Ford is recalling certain 2024 F-53 and F-59 stripped chassis vehicles because the instrument panel cluster may not properly display the transmission gear position indicator, failing FMVSS 102.

    Product
    FORD — FORD F-59, F-53
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V722000·2024-09-27

    Forest River Recalls 2024-2025 Viking and Clipper Trailers for Lighting Defect

    Forest River is recalling 2024-2025 Viking and Clipper travel trailers because side marker lights may not reflect light properly, reducing visibility to other drivers.

    Product
    FOREST RIVER — FOREST RIVER, VIKING TRAVEL TRAILERS CLIPPER CAMPING TRAILER, VIKING
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V716000·2024-09-27

    BMW R18 reverse gear control unit seal can let moisture in

    BMW is recalling certain 2021-2024 R18 motorcycles because the seal for the reverse gear control unit may deteriorate, allowing moisture inside and causing the unit to overheat.

    Product
    BMW — BMW R 18
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·24377·2024-09-26

    John Deere Compact Utility Tractors Recalled for Brake Failure Hazard

    Deere & Company is recalling about 147,900 John Deere 1023E, 1025R, and 2025R Compact Utility Tractors because the front bell crank in the brake linkage can fail, causing loss of braking and crash risk. Four failures have been reported, including one hospitalization and two impact injuries.

    Product
    John Deere 1023E, 1025R, and 2025R Compact Utility Tractors
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V717000·2024-09-26

    Brinkley Model Z safety chains are underrated for the weight rating

    Brinkley RV is recalling certain 2025 Model Z travel trailers because the installed safety chains are underrated for the Gross Vehicle Weight Rating. 40 units are affected.

    Product
    BRINKLEY RV — BRINKLEY RV MODEL Z
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V715000·2024-09-26

    Chrysler Recalls 2024 Ram Promaster BEV for Software Defect

    Chrysler is recalling 2024 Ram Promaster BEV vehicles because incorrect software may cause a loss of drive power, increasing crash risk.

    Product
    RAM — RAM PROMASTER BEV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V718000·2024-09-26

    Tesla Cybertruck rearview camera image may be delayed after shifting

    Tesla is recalling certain 2024 Cybertruck vehicles because the rearview camera image may be delayed after shifting into reverse, failing FMVSS 111. 27,185 units affected.

    Product
    TESLA — TESLA CYBERTRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V719000·2024-09-26

    Harley-Davidson Recalls 2018-2019 Softail Motorcycles for Tire Label Error

    Harley-Davidson is recalling 2018-2019 Softail FXBB and FXLR motorcycles because the front tire inflation pressure on the VIN label may be incorrect, potentially leading to tire overloading.

    Product
    HARLEY-DAVIDSON — HARLEY-DAVIDSON FXBB, FXLR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V711000·2024-09-25

    BMW and MINI front body structure bolts may not be tightened

    BMW is recalling certain 2023-2024 228i, 228i xDrive and 2025 MINI Countryman S ALL4 vehicles because the bolts connecting the front body structure to the chassis may be loose.

    Product
    BMW — BMW, MINI 228I XDRIVE, 228I, COUNTRYMAN S ALL4
    Category
    Vehicle
    Distribution
    Distributed nationwide