The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

801–825 of 15168

  • SevereNHTSA·25V735000·2025-10-27

    Tesla Cybertruck accessory light bar can loosen from the windshield

    Tesla is recalling certain 2024 Cybertruck vehicles fitted with a service-installed off-road light bar because an incorrect surface primer may allow the light bar to loosen and detach.

    Product
    TESLA — TESLA CYBERTRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V727000·2025-10-24

    Forest River toy hauler fresh water tank can detach when full

    Forest River is recalling certain 2021 XLR Toy Hauler travel trailers because the mounting brackets may be improperly located or secured, allowing the fresh water tank to detach when full.

    Product
    FOREST RIVER — FOREST RIVER XLR TOYHAULER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V725000·2025-10-24

    Mercedes-Benz Recalls Sprinter 2500 Vehicles Due to Frame Defect

    Daimler Vans USA is recalling 2023-2024 Mercedes-Benz Sprinter 2500 vehicles because a frame member may not be reinforced properly, reducing third-row seat structural integrity.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SPRINTER 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25E070000·2025-10-24

    Ford Recalls 10R80 Automatic Transmissions for Missing Bearing

    Ford is recalling specific 10R80 re-manufactured automatic transmissions used in 2017-2021 Ford and Lincoln vehicles because a missing T10 bearing may prevent the vehicle from holding the Park position.

    Product
    POWER TRAIN:AUTOMATIC TRANSMISSION recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V729000·2025-10-24

    Ford moonroof wind deflectors can detach from the vehicle

    Ford is recalling certain 2021-2023 Expedition, Navigator, F-150 and Super Duty vehicles because the moonroof wind deflector clips may be inadequately attached, letting the deflector detach.

    Product
    FORD — FORD, LINCOLN F-150, EXPEDITION, NAVIGATOR, F-250 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V726000·2025-10-24

    Ford Recalls 2026 Econoline Vehicles for HVAC Blower Motor Defect

    Ford is recalling 2026 Econoline vehicles because a failing HVAC blower motor can disable windshield defrosting, reducing visibility and increasing crash risk.

    Product
    FORD — FORD ECONOLINE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V731000·2025-10-24

    Ford Recalls 2022-2023 F-150 Lightning BEV for Rear Lightbar Defect

    Ford is recalling 2022-2023 F-150 Lightning BEVs previously repaired under recall 23V418 because rear lightbar microcracks can cause inoperative or flickering reverse lights.

    Product
    FORD — FORD F-150 LIGHTNING BEV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V730000·2025-10-24

    Ford and Lincoln windshields may have visible air bubbles

    Ford is recalling certain 2025-2026 Lincoln Corsair, Lincoln Aviator and Explorer vehicles because the windshield glass may have visible air bubbles that obscure the driver's visibility.

    Product
    FORD — FORD, LINCOLN EXPLORER, AVIATOR, CORSAIR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V732000·2025-10-24

    Ford Recalls 2017-2019 Flex Vehicles for Detaching B-Pillar Trim

    Ford is recalling 2017-2019 Flex vehicles because the driver and front passenger B-Pillar door trim may detach while driving, creating a road hazard.

    Product
    FORD — FORD FLEX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V724000·2025-10-23

    Wartech SpecialContainer Trailers Recalled for Brake Fitting Leak Risk

    Wartech is recalling 2022-2025 SpecialContainer trailers because an incorrect piping fitting may leak air, reducing brake pressure and increasing crash risk.

    Product
    WARTECH — WARTECH SPECIALCONTAINER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V721000·2025-10-23

    Ford Bronco front seat pivot bolts may be loose or dislodged

    Ford is recalling certain 2021-2023 Bronco vehicles because the front seats may have a loose or dislodged seat frame height-adjust pivot bolt, so the seat may not restrain an occupant in a crash.

    Product
    FORD — FORD BRONCO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V723000·2025-10-23

    Honda CB1000SP gearshift pedal pivot bolt can loosen and detach

    Honda is recalling certain 2025 CB1000SP Hornet SP motorcycles because the pivot bolt on the gearshift pedal may loosen and detach, leaving the rider unable to change gear. This fails FMVSS 123.

    Product
    HONDA — HONDA CB1000SP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V720000·2025-10-23

    Ram ProMaster radiator fan electrical circuit can overheat

    Chrysler is recalling certain 2018-2026 Ram ProMaster vehicles because the electrical circuit for the radiator fan may overheat, increasing the risk of a fire.

    Product
    RAM — RAM PROMASTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V722000·2025-10-23

    Maserati headlights may be missing their adjustment prevention caps

    Maserati is recalling certain 2023-2025 Grecale, Granturismo and Grancabrio vehicles because the headlights may be missing adjustment prevention caps, allowing them to be improperly adjusted.

    Product
    MASERATI — MASERATI GRECALE, GRANTURISMO, GRANCABRIO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V719000·2025-10-22

    Isuzu and Chevrolet axle stabilizer bracket bolts can crack and break

    Isuzu is recalling certain 2018-2026 Isuzu FVR and FTR and Chevrolet 6500XD and 7500XD vehicles because the axle stabilizer bracket bolts may crack and break, letting the bracket detach.

    Product
    ISUZU — ISUZU, CHEVROLET FTR, 6500XD, 7500XD, FVR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V716000·2025-10-21

    Ferrari Recalls 2025 296 GTS and GTB for Oil Leak Fire Risk

    Ferrari is recalling 2025 296 GTS and 296 GTB vehicles because an incorrectly tightened oil filter nut may cause an oil leak near combustible sources, increasing fire risk.

    Product
    FERRARI — FERRARI 296 GTS, 296 GTB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V715000·2025-10-21

    Fiat 500e headlight aim adjustment is not covered as intended

    Chrysler is recalling certain 2024-2025 Fiat 500e electric vehicles because the headlight horizontal aim adjustment is not covered as intended, which can leave the headlights improperly adjusted.

    Product
    FIAT — FIAT 500E
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V718000·2025-10-21

    Motorhome paddle latch can lock owners out of the propane compartment

    REV Recreation Group is recalling certain 2024-2026 Holiday Rambler Invicta and Fleetwood Fortis RVs because a paddle latch may lock unintentionally, blocking access to the liquid propane compartment.

    Product
    HOLIDAY RAMBLER — HOLIDAY RAMBLER, FLEETWOOD INVICTA, FORTIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V717000·2025-10-21

    2026 BMW X2 and Related Vehicles Seat Belt Retractor Failure Recall

    BMW is recalling certain 2026 X2, X1, 2 Series Gran Coupe, and Mini Countryman S ALL4 vehicles because the rear seat belt retractors may not lock properly due to damage during production, increasing injury risk in a crash.

    Product
    MINI — MINI, BMW COUNTRYMAN S ALL4, X2, X1, 228I XDRIVE GRAN COUPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V713000·2025-10-20

    ACP Cryogenic Tank Trailer Recall for Improperly Welded Suspension Towers

    Alloy Custom Products is recalling 2023-2025 ACP cryogenic tank trailers because improperly welded suspension towers may cause axle detachment and increase crash risk.

    Product
    ACP — ACP CRYOGENIC TANK TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V710000·2025-10-17

    Jeep Wrangler 4XE software update can cause loss of drive power

    Chrysler is recalling certain 2023-2025 Jeep Wrangler 4XE plug-in hybrids because a software error in an over-the-air update may result in a loss of drive power. The remedy is still under development.

    Product
    JEEP — JEEP WRANGLER 4XE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V712000·2025-10-17

    Mercedes Sprinter radar sensor failure can disable automatic emergency braking

    Daimler Vans is recalling certain 2025 Mercedes-Benz Sprinter 2500 vehicles because the front short-range radar sensor circuit board may fail, causing a loss of automatic emergency braking.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SPRINTER 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V708000·2025-10-17

    Forest River Recalls 2026 Wildwood and Salem Travel Trailers for Fire Risk

    Forest River is recalling 2026 Wildwood and Salem travel trailers because the exterior griddle may be stowed while connected to the LP gas line, increasing fire risk.

    Product
    FOREST RIVER — FOREST RIVER SALEM, WILDWOOD
    Category
    Vehicle
    Distribution
    Distributed nationwide