The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

651–675 of 7629

  • SevereNHTSA·25V127000·2025-02-28

    Ford Maverick control modules may miss a low 12-volt battery

    Ford is recalling certain 2022 Maverick vehicles previously repaired under 24V-590, because the body and powertrain control modules may fail to detect a change in 12-volt battery state of charge.

    Product
    FORD — FORD MAVERICK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V135000·2025-02-28

    Mercedes Sprinter parking brake bracket welds can fail causing rollaway

    Daimler Vans is recalling certain 2024 Mercedes-Benz Sprinter vehicles because the parking brake cable bracket welds may fail and disengage the parking brake, failing FMVSS 105.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SPRINTER 2500, SPRINTER 1500, SPRINTER 4500, SPRINTER 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V129000·2025-02-28

    Mercedes-Benz Recalls Hybrid AMG Models Due to Software Error

    Mercedes-Benz is recalling 2,943 hybrid AMG vehicles because a software error may cause the high-voltage starter alternator control unit to fail, resulting in a loss of drive power.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG GT63 S E, AMG GLC63 S E 4MATIC+ COUPE, AMG S 63 E, AMG GT 63 S E COUPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V121000·2025-02-27

    Motorhome exhaust tips can detach letting fumes into the cabin

    REV Recreation Group is recalling certain 2022-2025 Fleetwood and Holiday Rambler motorhomes because the engine exhaust tip may detach, allowing exhaust fumes to enter the cabin.

    Product
    FLEETWOOD — FLEETWOOD, HOLIDAY RAMBLER SOUTHWIND, INVICTA, ADMIRAL, VACATIONER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V116000·2025-02-24

    Mercedes-Benz Recalls S-Class Vehicles Due to Front Brake Hose Rupture Risk

    Mercedes-Benz is recalling 2021-2023 S-Class and Maybach vehicles because front brake hoses may rupture and leak fluid, increasing stopping distance and crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, MERCEDES-MAYBACH S 500, S 580, S 580 E, S 680
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V115000·2025-02-24

    Kia EV9 rear drive unit motor shaft may be improperly welded

    Kia is recalling certain 2025 EV9 vehicles because the rear gear drive unit motor shaft may have been improperly welded and become damaged, causing a loss of drive power.

    Product
    KIA — KIA EV9
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V109000·2025-02-21

    BMW X3 battery cable connection can overheat stalling the engine

    BMW is recalling certain 2025 X3 30 xDrive vehicles because the connection between the positive battery cable and the starter-generator may be improperly tightened and overheat.

    Product
    BMW — BMW X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V114000·2025-02-21

    Spartan RV chassis fuel filter hose can separate causing leak and stall

    Shyft Group is recalling certain 2022-2025 Spartan RV Chassis K2 vehicles with Cummins L9 diesel engines because the remote fuel filter hose may separate from the fitting.

    Product
    SPARTAN — SPARTAN K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V106000·2025-02-20

    BMW X3 rear door locks can be released with one motion

    BMW is recalling certain 2022-2024 X3 sDrive30i and xDrive30i vehicles because second-row door locking modules may allow the doors to be unlocked with a single motion, failing FMVSS 206.

    Product
    BMW — BMW X3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V102000·2025-02-18

    Volvo VN truck brakes may take longer than expected to activate

    Volvo Trucks is recalling certain 2023-2025 New VN trucks because the brakes may take longer than expected to activate, extending stopping distance. This fails FMVSS 121.

    Product
    VOLVO — VOLVO VNL (4), VNR (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V099000·2025-02-17

    Kia Seltos and Soul piston oil rings can cause engine damage

    Kia is recalling certain 2021-2023 Seltos and Soul vehicles because incorrectly manufactured piston oil rings can result in engine damage, which may cause a stall or a fire.

    Product
    KIA — KIA SELTOS, SOUL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V097000·2025-02-17

    Thor motorhome roof brackets missing washers can drop solar panels

    Thor Motor Coach is recalling certain 2023 Gemini and Compass motorhomes because washers were not installed with the roof mounting brackets, so the solar panel can detach.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH COMPASS, GEMINI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V092000·2025-02-14

    Tesla Model 3 and Model Y may lose power steering assist

    Tesla is recalling certain 2023 Model 3 and Model Y vehicles because an overstress condition in the power steering circuit board can cause a loss of power steering assist.

    Product
    TESLA — TESLA MODEL Y, MODEL 3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V090000·2025-02-14

    Mercedes-Benz eSprinter rear axle gear welds may fail in service

    Daimler Vans is recalling certain 2024 Mercedes-Benz eSprinter vehicles because welds on the helical gear within the rear axle drivetrain may fail, causing a loss of drive power.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ ESPRINTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25E011000·2025-02-14

    MORryde Suspension Recall for Grand Design Serenova Travel Trailers

    MORryde is recalling IST22-008 suspensions on Grand Design Serenova travel trailers because improperly tightened axle bearing nuts may cause overheating and tire detachment.

    Product
    WHEELS:LUGS/NUTS/BOLTS/STUDS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V096000·2025-02-14

    Ford Mustang steering torque sensors may turn the wheel unintentionally

    Ford is recalling certain 2022-2023 Mustang vehicles previously repaired incorrectly under recall 24V-493, because a miscalibrated torque sensor can turn the steering wheel unbidden.

    Product
    FORD — FORD MUSTANG
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V087000·2025-02-13

    GM Recalls 2025 Chevrolet Express and GMC Savana Vans for Door Welds

    General Motors is recalling 2025 Chevrolet Express and GMC Savana vans because improper welds on the driver's side door impact beam may reduce occupant protection in a crash.

    Product
    GMC — GMC, CHEVROLET SAVANA, EXPRESS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V084000·2025-02-13

    Terex Advance Recalls 2024 Commander Vehicles Due to Axle Bearing Defect

    Terex Advance is recalling 2024 Commander vehicles because an incorrect front axle thrust bearing may cause the axle shaft to break, increasing the risk of a crash.

    Product
    TEREX ADVANCE — TEREX ADVANCE COMMANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V089000·2025-02-13

    Land Rover Recalls 2020 Range Rover Evoque for Knee Air Bag Cover Defect

    Jaguar Land Rover is recalling 2020 Range Rover Evoque vehicles because the left-side lower knee air bag cover may come loose, potentially preventing proper deployment in a crash.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER EVOQUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V077000·2025-02-12

    Terberg Benschop Recalls 2023-2024 YT Series Vehicles for Steering Defect

    Terberg Benschop is recalling 2023-2024 YT Series vehicles because a steering arm bolt may be improperly tightened, risking loss of steering and a crash.

    Product
    TERBERG BENSCHOP B.V. — TERBERG BENSCHOP B.V. YT SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide