The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1251–1275 of 14942

  • HighNHTSA·25V336000·2025-05-22

    Mazda MX-5 recalled for Dynamic Stability Control indicator light failure

    Mazda is recalling 2024-2025 MX-5 vehicles where the Dynamic Stability Control indicator light may fail to illuminate due to a software error. This could prevent drivers from being warned of a traction control system failure, increasing crash risk.

    Product
    MAZDA — MAZDA MX-5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25E037000·2025-05-22

    Zoox Recalls Driverless Vehicles for Software Defect in Person Detection

    Zoox is recalling Automated Driving Systems with older software that may fail to detect people next to the vehicle, increasing injury risk.

    Product
    ELECTRICAL SYSTEM:ADAS:AUTONOMOUS/SELF DRIVING:SOFTWARE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V335000·2025-05-22

    Shyft Recalls 2022-2024 Utilimaster Velocity Vehicles Missing Tire Placards

    Shyft Group is recalling 2022-2024 Utilimaster Velocity vehicles because they may be missing the tire and information placard, which is required by federal safety standards.

    Product
    UTILIMASTER — UTILIMASTER VELOCITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V330000·2025-05-21

    Ram ProMaster rearview camera image may not display in reverse

    Chrysler is recalling certain 2022-2025 Ram ProMaster vehicles because a software error in the security gateway module may prevent the rearview camera image displaying, failing FMVSS 111.

    Product
    RAM — RAM, BRAUN PROMASTER, RAM PROMASTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V334000·2025-05-21

    Volkswagen Atlas rearview camera image can become distorted in reverse

    Volkswagen is recalling certain 2024-2025 Atlas and Atlas Cross Sport vehicles because a software error may distort the rearview camera image when the vehicle is in reverse.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS, ATLAS CROSS SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V333000·2025-05-21

    Mack Recalls 2026 MD Trucks Due to Incorrect Seat Belt Routing

    Mack Trucks is recalling 2026 MD vehicles because the center bench seat belt assembly may be routed incorrectly, potentially failing to restrain occupants in a crash.

    Product
    MACK — MACK MD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25E036000·2025-05-21

    Holley Recalls Fuel Pressure Regulators Due to Leak Risk

    Holley Performance Products is recalling specific Fuel Pressure Regulators because a damaged diaphragm may cause a fuel leak, increasing the risk of fire.

    Product
    FUEL SYSTEM, GASOLINE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V327000·2025-05-20

    Braun Recalls Demers Ambulances Due to Unsecured Cushion Equipment Storage

    Braun Industries is recalling specific Demers ambulance models because improperly installed cushion equipment storage may allow items to detach during transit, increasing injury risk.

    Product
    DEMERS — DEMERS, DEMERS AMBULANCES TSE, MX164E, TXE, MXP150E
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V328000·2025-05-20

    Orange EV Recalls Electric Trucks Due to Obstructed Backup Lights

    Orange EV is recalling specific electric trucks because a pintle hook blocks the backup lights, reducing visibility and increasing crash risk.

    Product
    ORANGE EV — ORANGE EV E-TRIEVER, HUSK-E, T-SERIES ELECTRIC TRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V319000·2025-05-16

    Isuzu Recalls 2025 NRR EV Due to Electrical Overheating Risk

    Isuzu is recalling 2025 NRR EV vehicles because a gap in the electrical system may cause overheating and loss of drive power, increasing crash risk.

    Product
    ISUZU — ISUZU NRR EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V269000·2025-05-15

    Volkswagen ID. Buzz third-row bench seats three but has two belts

    Volkswagen is recalling certain 2025 ID. Buzz vehicles because the third-row bench is wide enough for three passengers but is designed for two and has only two seat belts, failing FMVSS 208.

    Product
    VOLKSWAGEN — VOLKSWAGEN ID. BUZZ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V323000·2025-05-15

    School bus parking brake can release while wheelchair lift is deployed

    International is recalling certain 2025-2026 IC Bus CESB school buses because the parking brake can be released while the wheelchair platform lift is deployed, failing FMVSS 403.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V321000·2025-05-15

    Keystone Recalls Travel Trailers With Detachable Step Bracket Defect

    Keystone RV Company is recalling specific 2024-2025 travel trailers because step mounting bolts may loosen, allowing steps to detach and increase injury risk.

    Product
    KEYSTONE — KEYSTONE RESIDENCE, RETREAT, SPRINGDALE, VOLTAGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V322000·2025-05-15

    Toyota Tundra reverse lights can fail from moisture in the assembly

    Toyota is recalling certain 2022-2025 Tundra and Tundra Hybrid vehicles because moisture may enter the reverse light assemblies and cause the lights to fail.

    Product
    TOYOTA — TOYOTA TUNDRA HYBRID, TUNDRA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V273000·2025-05-14

    Ford Bronco 360-degree cameras may not display a rearview image

    Ford is recalling certain 2022-2023 Bronco vehicles because the 360-degree view camera may not display a rearview image when the vehicle is placed in reverse.

    Product
    FORD — FORD BRONCO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V215000·2025-05-13

    Mitsubishi Fuso Recalls 2024 Rizon Trucks for Turn Signal Defect

    Mitsubishi Fuso is recalling 243 2024 Rizon trucks because a defective bulb socket may cause front turn signals to burn out, increasing crash risk.

    Product
    MITSUBISHI FUSO — MITSUBISHI FUSO RIZON FEC7K (E16), RIZON FEC9K (E18)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V255000·2025-05-12

    Mercedes-Benz Recalls Vehicles With Incorrect Fuse Boxes From Prior Repair

    Mercedes-Benz is recalling 443 vehicles that received an incorrect fuse box during a previous recall. The defect may cause loss of drive power, safety functions, or fire.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, MERCEDES-MAYBACH AMG EQS 53 4MATIC, AMG SL55 4MATIC+, AMG EQE 53 4MATIC, AMG SL63 4MATIC+
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25E034000·2025-05-12

    Waymo Recalls 5th Generation Automated Driving Systems for Collision Risk

    Waymo is recalling 5th Generation Automated Driving Systems with older software that may cause vehicles to collide with roadway barriers like chains and gates.

    Product
    ELECTRICAL SYSTEM:ADAS:AUTONOMOUS/SELF DRIVING:SOFTWARE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V317000·2025-05-12

    ATC Recalls 2025 PLA550 Trailers Due to Wiring Fire Risk

    ATC is recalling 2025 PLA550 Bumper Pull trailers because the power wire to stabilizer jacks may lack over-current protection, increasing fire risk.

    Product
    ATC — ATC PLA550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V309000·2025-05-09

    Ford Recalls 2025 F-150 Trucks for Steering Shaft Fastener Defect

    Ford is recalling 2025 F-150 vehicles because lower steering shaft fasteners may detach, causing loss of steering control and increasing crash risk.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V314000·2025-05-09

    Ford Expedition front brake lines may contact the air cleaner pipe

    Ford is recalling certain 2022-2024 Expedition and Lincoln Navigator vehicles because front brake lines may contact the engine air cleaner outlet pipe and leak brake fluid.

    Product
    FORD — FORD, LINCOLN EXPEDITION, NAVIGATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V310000·2025-05-09

    Ford Bronco upper control arm ball joint fasteners may be missing

    Ford is recalling certain 2024-2025 Bronco and Ranger vehicles because the front upper control arm ball joint fastener may be missing or improperly tightened.

    Product
    FORD — FORD BRONCO, RANGER
    Category
    Vehicle
    Distribution
    Distributed nationwide