The Recall Desk

Manufacturer

Porsche Cars North America, Inc.

121 recalls in our database name Porsche Cars North America, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
121
Critical
0
Severe
58
Most recent
2026-10-16

Of the 121 recalls from Porsche Cars North America, Inc. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 58 (48%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

51–75 of 121

  • HighNHTSA·21V486000·2021-06-29

    Porsche Recalls 2020-2021 Taycan Models for Powertrain Software Fault

    Porsche is recalling certain 2020-2021 Taycan models due to a software monitoring fault that can incorrectly shut down the powertrain, causing loss of motive power and increasing crash risk.

    Product
    PORSCHE — PORSCHE TAYCAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V362000·2021-05-17

    2021 Porsche Taycan and Panamera Front Suspension Trailing Arm Defect Recall

    Porsche is recalling certain 2021 Taycan and Panamera models due to front lower trailing arms that may not be properly forged and could break, risking loss of vehicle control.

    Product
    PORSCHE — PORSCHE PANAMERA 4S E-HYBRID, PANAMERA 4S, PANAMERA 4 E-HYBRID, PANAMERA TURBO S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V341000·2021-05-12

    2021 Porsche Cayenne GTS Engine Cylinder Bore Crack Recall

    Porsche is recalling 2021 Cayenne GTS vehicles due to engine cylinder bore cracks that may cause engine damage, stalling, or oil leaks, increasing the risk of a crash or fire. Dealers will replace the engine at no charge.

    Product
    PORSCHE — PORSCHE CAYENNE GTS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V318000·2021-05-05

    2021 and 2020 Porsche Cayenne passenger airbag may fail to deploy

    Porsche is recalling certain 2020-2021 Cayenne models because the passenger seat heating element may not be installed, preventing proper airbag calibration and risking airbag deployment failure.

    Product
    PORSCHE — PORSCHE redundant CAYENNE E-HYBRID, CAYENNE E-HYBRID, CAYENNE GTS, CAYENNE S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V271000·2021-04-21

    2021 Porsche Cayenne recalled for rear axle suspension defect

    Porsche is recalling certain 2021 Cayenne models because lock nuts on the rear axle may break due to stress corrosion, potentially causing loss of control and crash risk.

    Product
    PORSCHE — PORSCHE CAYENNE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V224000·2021-03-31

    2021 Porsche Macan recalled for loose shock absorber screw connections

    Certain 2021 Porsche Macan models have improperly tightened screw connections on shock absorbers, which could compromise braking and vehicle control. Porsche will repair the connections free of charge.

    Product
    PORSCHE — PORSCHE MACAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V200000·2021-03-24

    Porsche Recalls 2021 Models Due to Engine Connecting Rod Defect

    Porsche is recalling 2021 Cayman, Boxster, and 718 Spyder vehicles because engine connecting rods may crack and loosen, increasing the risk of a crash or fire.

    Product
    PORSCHE — PORSCHE redundant CAYMAN, redundant BOXSTER, 718 SPYDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V157000·2021-03-10

    2021 Porsche vehicles recalled for potentially loose suspension components

    Porsche is recalling certain 2021 Taycan, 911, Cayman, Boxster, and 718 Spyder models because suspension components may not have been properly tightened and could loosen, potentially causing loss of vehicle control.

    Product
    PORSCHE — PORSCHE TAYCAN, redundant CAYMAN, redundant BOXSTER, 911
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V131000·2021-03-03

    Porsche Recalls Macan Models Due to Front Passenger Air Bag Sensor Defect

    Porsche is recalling certain 2015-2018 Macan models because the front passenger seat occupancy sensor may fail to detect a passenger, preventing the air bag from deploying.

    Product
    PORSCHE — PORSCHE MACAN S, MACAN TURBO, MACAN, MACAN GTS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V381000·2020-07-01

    Porsche Recalls 2020 911 Carrera 4S Coupe for Differential Bracket Issue

    Porsche is recalling 2020 911 Carrera 4S Coupe vehicles because the front axle differential bracket may not be tightened correctly, potentially causing damage to surrounding components and increasing fire risk.

    Product
    PORSCHE — PORSCHE 911 CARRERA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V270000·2020-05-13

    Porsche Recalls 2019-2020 Cayenne Models Due to Fuel Line Leak Risk

    Porsche is recalling 2,253 Cayenne vehicles because a fuel line connector may leak, increasing the risk of fire.

    Product
    PORSCHE — PORSCHE CAYENNE TURBO S HYB COUPE, CAYENNE S E-HYBRID, CAYENNE TURBO, CAYENNE TURBO COUPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V271000·2020-05-13

    Porsche Recalls 2020 Cayenne for Transmission Oil Pipe Weld Defect

    Porsche is recalling 2020 Cayenne vehicles because an insufficient weld on a transmission oil pipe may cause fluid leaks, potentially making roads slippery and increasing crash risk.

    Product
    PORSCHE — PORSCHE CAYENNE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V875000·2019-12-11

    Porsche Recalls 15,501 Vehicles for Child Seat Manual Deficiency

    Porsche is recalling 15,501 vehicles because the owner's manual lacks specific instructions for installing child restraint systems, which may increase injury risk in a crash.

    Product
    PORSCHE — PORSCHE CAYMAN, 911 GT3, 911 GT3 RS, 911 R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V735000·2019-10-16

    Porsche Recalls Cayenne and Panamera for Brake Warning Defect

    Porsche is recalling 2017-2020 Cayenne and Panamera vehicles because the instrument cluster may fail to warn drivers when brake pads are worn out.

    Product
    PORSCHE — PORSCHE CAYENNE, PANAMERA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V533000·2019-07-17

    Porsche Recalls 2016-2017 Models for Air Bag Control Module Defect

    Porsche is recalling 2016-2017 911, Boxster, Cayman, and Panamera vehicles because a defective capacitor in the air bag control unit may cause air bags to fail or deploy unexpectedly.

    Product
    PORSCHE — PORSCHE 718 BOXSTER, PANAMERA, 911, 718 CAYMAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V445000·2019-06-12

    Porsche Recalls 2019-2020 Models for Driveshaft Bolt Tightening Issue

    Porsche is recalling 2019 911 GT2 RS and 2020 911 Carrera S Coupe vehicles because driveshaft bolts may not be properly tightened, increasing crash risk.

    Product
    PORSCHE — PORSCHE 911 CARRERA, 911 GT2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V446000·2019-06-12

    Porsche Recalls Vehicles Due to Gear Selector Bushing Defect

    Porsche is recalling specific Cayenne and Panamera models because a degraded bushing may allow the driver to exit the vehicle while the transmission is not in Park, increasing crash risk.

    Product
    PORSCHE — PORSCHE PANAMERA, CAYENNE S, CAYENNE TURBO, CAYENNE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V322000·2019-04-24

    Porsche Recalls Panamera Models Due to Electrical Fire Risk

    Porsche is recalling 2010-2016 Panamera vehicles because water in the A/C blower control unit can cause an electrical short and fire.

    Product
    PORSCHE — PORSCHE PANAMERA, PANAMERA S E-HYBRID, PANAMERA S, PANAMERA 4S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V179000·2019-03-06

    Porsche Recalls 2018 Models for Loose Side Air Bag Sensors

    Porsche is recalling 417 vehicles because side air bag impact sensors may not be properly tightened, which could prevent air bag deployment in a crash.

    Product
    PORSCHE — PORSCHE 911, 718 BOXSTER, 718 CAYMAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V180000·2019-03-06

    Porsche Recalls 2018 Panamera Models Due to Electrical Control Unit Defect

    Porsche is recalling 2018 Panamera models because incorrect soldering on a control unit may cause intermittent system failures and impaired driveability.

    Product
    PORSCHE — PORSCHE PANAMERA TURBO SPORT TURI, PANAMERA 4S EXECUTIVE, PANAMERA TURBO S HYBRID E, PANAMERA
    Category
    Vehicle
    Distribution
    Distributed nationwide