The Recall Desk

Hazard

Driveshaft Separation recalls

21 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
21
Critical
0
Severe
15
Most recent
2026-09-09

Of the 21 driveshaft separation recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 15 (71%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all driveshaft separation recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–21 of 21

  • SevereNHTSA·26V576000·2026-09-09

    Ford Recalls 2026 F-150s Due to Rear Axle Bearing Defect

    Ford is recalling 2026 F-150 vehicles because incorrect rear axle tail bearings may cause wheel lock-up or driveshaft separation, increasing crash risk.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V862000·2024-11-15

    Mercedes-Benz Recalls 2024 GLC 300 and S 580 for Driveshaft Separation Risk

    Mercedes-Benz is recalling 2024 GLC 300 and S 580 vehicles because rear axle differential bolts may loosen, causing driveshaft separation and loss of drive power.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ S 580 4MATIC, GLC 300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V158000·2024-02-28

    Jayco Recalls 2024 Motorhomes Due to Rear Axle Lubricant Defect

    Jayco is recalling 2024 Entegra and Jayco motorhomes because inadequate rear axle lubricant may cause bearing damage, leading to wheel lock-up or driveshaft separation.

    Product
    ENTEGRA — ENTEGRA, JAYCO CONDOR, SOLSTICE, EXPANSE LI, EXPANSE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V482000·2023-07-12

    Nova Bus LFS Transit Buses Recalled for Driveshaft Separation

    Nova Bus is recalling certain 2019-2023 LFS and LFS Artic transit buses. The transmission yoke may separate, causing driveshaft separation and sudden loss of drive power, increasing the risk of crashes and passenger injury.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V153000·2023-03-08

    2023 International MV and HV Vehicles Recalled for Driveshaft Separation Risk

    Navistar is recalling certain 2023 International HV and 2023-2024 International MV vehicles due to incorrectly installed rear axle wedge shims that can cause driveshaft separation and loss of drive power. This increases the risk of a crash.

    Product
    INTERNATIONAL — INTERNATIONAL MV, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V145000·2023-03-03

    Xos Recalls 275 Vehicles Due to Driveshaft Bolt Tightening Defect

    Xos is recalling 275 RM01, SA01, and SV05 vehicles because improperly tightened bolts may allow the driveshaft to separate, increasing crash risk.

    Product
    XOS — XOS RM01, SV05, SA01
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V043000·2023-02-02

    2023 GMC Acadia: Right-front half-shaft separation from transmission risk

    General Motors is recalling certain 2023 GMC Acadia vehicles because right-front half-shaft assemblies may separate from the transmission, potentially causing loss of drive power or vehicle rollaway and increasing crash risk.

    Product
    CADILLAC — CADILLAC, GMC XT5, ACADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V536000·2021-07-15

    2020-2021 Ford F-350 Super Duty Pickup Trucks Rear Axle Housing Recall

    Ford is recalling 2020-2021 F-350 Super Duty pickup trucks with 6.7L diesel engines due to rear axle housing that may deform. Driveshaft separation could cause loss of drive power or unexpected vehicle movement, increasing crash risk.

    Product
    FORD — FORD F-350 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V478000·2021-06-25

    Mercedes-Benz Recalls AMG GT Vehicles for Driveshaft Separation Risk

    Mercedes-Benz is recalling 2016-2018 AMG GT vehicles because an insufficient bond between the carbon-fiber driveshaft and flange could cause separation, leading to loss of drive power and increased crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V381000·2021-05-24

    Ford Recalls 2021 F-150 Trucks Due to Driveshaft Assembly Defect

    Ford is recalling 2021 F-150 vehicles because improperly assembled driveshafts may separate, potentially causing loss of drive power or unintended movement.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V650000·2020-10-22

    GM Recalls 2019-2020 Silverado and Sierra Trucks for Driveshaft Defect

    General Motors is recalling 2019-2020 Chevrolet Silverado and GMC Sierra trucks because a driveshaft joint may not be properly welded, risking separation and loss of propulsion.

    Product
    CHEVROLET — CHEVROLET, GMC SILVERADO 2500, SILVERADO 1500, SIERRA 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V178000·2020-03-25

    Thor Motor Coach motorhomes recalled for faulty rear axle differential

    Thor Motor Coach is recalling certain 2020-2021 motorhomes due to insufficient rear axle differential fluid that could cause driveshaft separation and loss of vehicle drive, increasing crash risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH VEGAS, AXIS, CHATEAU, FOUR WINDS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V099000·2020-02-21

    2021 Ford E-350 Recalled for Rear Axle Differential Fluid Deficiency

    The 2021 Ford E-350 may have inadequate rear axle differential fluid, risking driveshaft separation and loss of drive. Ford will inspect and adjust or replace the rear axle assembly at no cost.

    Product
    FORD — FORD F-550, E-450, E-350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V457000·2019-06-14

    Mercedes-Benz Recalls AMG GT Vehicles for Driveshaft Separation Risk

    Mercedes-Benz is recalling 2016-2017 AMG GT vehicles because the carbon-fiber driveshaft may separate, causing a loss of drive and increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V424000·2019-06-06

    Acura Recalls 2016-2019 ILX Vehicles for Driveshaft Separation Risk

    Acura is recalling 2016-2019 ILX vehicles because excessive grease may prevent a set-ring from engaging, allowing the driveshaft to separate and increase crash risk.

    Product
    ACURA — ACURA ILX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V669000·2018-09-25

    Maintainer Service Mechanic Bodies Recalled for Driveshaft Interference Risk

    Maintainer is recalling 2017-2018 Service Mechanic Bodies mounted on Ford F-Series Super Duty trucks because a hydraulic pump may interfere with the front axle driveshaft, potentially causing separation and increasing crash risk.

    Product
    MAINTAINER — MAINTAINER SERVICE/MECHANICBODY FORD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11V407000·2011-08-05

    New Flyer Recalls 2005-2010 Buses for Driveshaft Bolt Failure Risk

    New Flyer is recalling certain 2005-2010 heavy-duty transit buses because retaining bolts on the propulsion system may fail, potentially causing the driveshaft to separate from the vehicle.

    Product
    NEW FLYER — NEW FLYER H40LFR, GE35LFR, GE40LF, GE40LFA
    Category
    Vehicle
    Distribution
    Distributed nationwide