The Recall Desk

Agency

National Highway Traffic Safety Administration

NHTSA oversees recalls of vehicles, tires, child seats, and motor-vehicle equipment. Each campaign is identified by an NHTSA campaign number.

Visit the official NHTSA site →

About NHTSA recalls

NHTSA regulates the safety of every motor vehicle sold in the US plus tires, child seats, and motor-vehicle equipment. Recalls are coordinated under a numbering scheme called the NHTSA Campaign Number — a string like 25V123000 where the first two digits are the year, V is for vehicle (T is for tires, C for child seats, E for equipment), and the rest identifies the campaign. Every vehicle in our database can be looked up by VIN to check whether any active campaigns affect it.

NHTSA recalls are unusual in two ways. First, the cause is usually a defined defect or non-compliance with a Federal Motor Vehicle Safety Standard rather than a pathogen or contamination event — so 'severity' tracks the consequence of the defect (does the airbag fail to deploy, does the steering lose assist, does the fuel tank leak) rather than reported illnesses. Second, every NHTSA recall is mandatory for the manufacturer to remedy at no charge to the owner, for as long as the vehicle is on the road. There's no expiration on a NHTSA campaign.

We enrich every recall with the full make / model / year-range affected so you can see at a glance whether your vehicle is in scope. If you're not sure, the VIN lookup decodes your specific vehicle and cross-references the database. The remedy is always free — usually a dealer visit for a part replacement, software update, or inspection.

10701–10725 of 15413

  • SevereNHTSA·16V109000·2016-02-25

    Honda Recalls 2014 NSS300 Scooters for Rear Brake Line Leak

    Honda is recalling 2014 NSS300 and NSS300A scooters because improperly tightened rear brake lines may leak fluid, reducing braking function and increasing crash risk.

    Product
    HONDA — HONDA NSS300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V112000·2016-02-25

    Open Range Journeyer Trailers Recalled for Underrated Safety Chains

    Open Range is recalling 2012-2015 Journeyer trailers because the safety chains are not rated high enough to support the trailer's weight if the main connection fails.

    Product
    OPEN RANGE — OPEN RANGE JOURNEYER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V110000·2016-02-25

    Ford Recalls 2016 F-150 Trucks Due to Air Bag Sensor Defect

    Ford is recalling 2016 F-150 trucks with Multi-Contour Seats because the passenger air bag sensor may misclassify adults as children, preventing air bag deployment.

    Product
    FORD — FORD F-150
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V111000·2016-02-25

    Ford Recalls 2015-2016 Transit Vehicles for Rear Seat Belt Defect

    Ford is recalling 2015-2016 Transit vans because rear seat belt buckles may fail to latch if damaged by heavy objects, increasing crash injury risk.

    Product
    FORD — FORD TRANSIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V108000·2016-02-24

    GM Recalls 2016 Buick Regal for Power Steering Failure Risk

    General Motors is recalling 2016 Buick Regal vehicles because the power-steering assist system may fail, increasing crash risk.

    Product
    BUICK — BUICK REGAL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V106000·2016-02-24

    Temsa Recalls 2016 TS45 and TS35C Buses for Front Control Arm Defect

    Temsa is recalling 70 model year 2016 TS45 and TS35C buses because front lower control arm housings may crack. This defect could cause a loss of steering and increase the risk of a crash.

    Product
    TEMSA — TEMSA TS45, TS35C
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V105000·2016-02-24

    Isuzu Recalls 2016 Trucks Due to Certification Label Errors

    Isuzu is recalling certain 2016 NPR-HD, NPR-XD, NQR, and NRR trucks because typographical errors on the certification label may prevent accurate vehicle loading and maintenance.

    Product
    ISUZU — ISUZU NPR HD, NPR XD, NQR, NRR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V102000·2016-02-23

    Kawasaki Recalls 2016 Ninja ZX-10R Motorcycles for Steering Bolt Defect

    Kawasaki is recalling 544 model year 2016 Ninja ZX-10R motorcycles because steering damper bracket mounting bolts may break, potentially interfering with steering and increasing crash risk.

    Product
    KAWASAKI — KAWASAKI NINJA ZX-10R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V100000·2016-02-23

    Blue Bird Recalls 2008-2009 Vision School Buses for Fire Risk

    Blue Bird is recalling 733 model year 2008-2009 Vision school buses because a wiring defect may cause the battery cable to overheat, melt, and create a fire risk.

    Product
    BLUE BIRD — BLUE BIRD VISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V101000·2016-02-23

    Blue Bird Recalls 2009 Vision Transit Buses for Electrical Fire Risk

    Blue Bird is recalling 2009 Vision transit buses with Caterpillar C707 engines because a wiring defect may cause the battery cable to overheat, melt, and create a fire hazard.

    Product
    BLUE BIRD — BLUE BIRD VISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V103000·2016-02-23

    Thomas Built Buses Recalls Minotour School Buses for Lighting Defect

    Daimler Trucks North America is recalling 2012-2017 Thomas Built Buses Minotour school buses because a body control module failure may cause loss of exterior lighting or windshield wipers.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES MINOTOUR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V099000·2016-02-19

    Mack Trucks Recalls 2012-2016 Models for Driveshaft Cap Nut Defect

    Mack Trucks is recalling 33,981 model year 2012-2016 trucks because a cap nut may loosen, causing the driveshaft to disconnect and increasing crash risk.

    Product
    MACK — MACK TITAN (TD), PINNACLE (CHU), TERRAPRO (LEU), PINNACLE (CXU)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V096000·2016-02-19

    Toyota Recalls RAV4 Models Due to Rear Seat Belt Cut Risk

    Toyota is recalling 2006-2012 RAV4 and 2012-2014 RAV4 EV vehicles because rear seat belts may be cut by the seat cushion frame in a frontal collision, increasing injury risk.

    Product
    TOYOTA — TOYOTA RAV4 EV, RAV4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V098000·2016-02-19

    Mack Trucks Recalls 2016-2017 Granite and TerraPro for Steering Defect

    Mack Trucks is recalling 1,187 model year 2016-2017 Granite and TerraPro trucks because a missing roll pin may cause the steering shaft to disconnect, resulting in a complete loss of steering.

    Product
    MACK — MACK TERRAPRO (MRU), GRANITE (GU)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V095000·2016-02-19

    Volvo Trucks Recall 2009-2016 Models for Steering Component Failure Risk

    Volvo Trucks North America is recalling certain 2009-2010 VT and 2016 VNL/VNM trucks because front suspension drag links may corrode, potentially causing loss of steering.

    Product
    VOLVO — VOLVO VT, VNM, VNL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V092000·2016-02-18

    Highland Ridge RV Recalls Trailers Due to Incorrect Weight Rating Labels

    Highland Ridge RV is recalling 2015-2016 travel and fifth wheel trailers because incorrect Gross Vehicle Weight Rating labels may allow overloading, increasing the risk of tire failure and crashes.

    Product
    HIGHLAND RIDGE TT — HIGHLAND RIDGE TT, HIGHLAND RIDGE FW ROAMER, HIGHLANDER, LIGHT, MESA RIDGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V093000·2016-02-18

    Mercedes-Benz and Freightliner Sprinter Vans Recalled for Incorrect Tire Labels

    Daimler Vans USA is recalling 2015-2016 Sprinter vans because tire pressure labels list incorrect maximum load capacities, which could lead to axle or tire failure.

    Product
    FREIGHTLINER — FREIGHTLINER, MERCEDES-BENZ SPRINTER 2500, SPRINTER 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16C003000·2016-02-18

    Evenflo Recalls Transitions 3-in-1 Booster Seats Due to Harness Defect

    Evenflo is recalling specific Transitions 3-in-1 Combination Booster Seats because the harness adjuster button may be within a child's reach, allowing them to loosen the harness and increasing injury risk in a crash.

    Product
    CHILD SEAT:HARNESS:STRAP/WEBBING recall
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·16V091000·2016-02-18

    Navistar Recalls 2016-2017 IC CE School Buses for Hood Strap Defect

    Navistar is recalling 2016-2017 IC CE school buses because hood straps may elongate, allowing the hood to open unexpectedly during braking and obstructing the driver's vision.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·16V097000·2016-02-17

    Volvo Recalls 2016-2017 Trucks for Steering Shaft Separation Risk

    Volvo is recalling 2016-2017 VNL, VNX, and VNM trucks because a missing roll pin or loose bolt may cause the steering shaft to separate, resulting in a loss of steering.

    Product
    VOLVO — VOLVO VNX, VNM, VNL
    Category
    Vehicle
    Distribution
    Distributed nationwide