  • Severity pendingNHTSA·25V898000·2025-12-19

    New Flyer Transit Bus Recall for Antilock Braking System Failure

    New Flyer is recalling certain transit buses because the antilock braking and stability control modules may fail without warning lights, increasing crash risk.

    Product
    NEW FLYER — NEW FLYER XE40, XE60, XHE40, XHE60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V943000·2022-12-20

    New Flyer Transit Buses Recalled for Steering Column Defect

    New Flyer is recalling 746 transit buses because a loose steering column connection may cause loss of steering, increasing crash risk.

    Product
    NEW FLYER — NEW FLYER XT40, XDE35, XN40, XT60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·22V637000·2022-08-24

    New Flyer Transit Buses Recalled for Steering Gear Fracture Risk

    New Flyer is recalling 2021-2022 transit buses because incorrectly assembled steering gears may fracture, potentially causing a loss of steering control.

    Product
    NEW FLYER — NEW FLYER XD40, XE40, XN40, XN35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V615000·2018-09-12

    New Flyer Transit Buses Recalled for Transmission Pressure Switch Failure

    New Flyer is recalling 386 XDE40, XDE60, and XDE35 transit buses because pressure switches may fail, causing a loss of drive and increasing crash risk.

    Product
    NEW FLYER — NEW FLYER XDE40, XDE60, XDE35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V155000·2018-03-07

    New Flyer Recalls Transit Buses Due to Drive Shaft End-Cap Failure Risk

    New Flyer is recalling 2016-2018 XDE40, XDE60, and 2017 XDE35 buses because plastic drive shaft end-caps may crack, causing loss of drive power and increasing crash risk.

    Product
    NEW FLYER — NEW FLYER XDE40, XDE60, XDE35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V020000·2018-01-09

    New Flyer Transit Buses Recalled for Air Brake Hose Tightness Issue

    New Flyer is recalling 283 transit buses because improperly tightened air brake hoses may disconnect, increasing braking distance and crash risk.

    Product
    NEW FLYER — NEW FLYER XT60, XN40, XDE60, XDE40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V562000·2015-09-04

    New Flyer Transit Buses Recalled for Potential Steering Loss

    New Flyer is recalling 432 transit buses from 2013-2015 because a tie rod clamp may be improperly torqued, risking a loss of steering.

    Product
    NEW FLYER — NEW FLYER XN40, XN35, XD40, XD60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V519000·2014-08-28

    New Flyer Recalls 2014 Transit Buses Due to Fuel Filter Defect

    New Flyer is recalling 2014 transit buses because a fuel filter defect may cause the engine to stall without warning, increasing the risk of a crash.

    Product
    NEW FLYER — NEW FLYER XDE60, XDE40, XD60, XD40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V487000·2013-10-17

    New Flyer Recalls 2013 Buses Due to Air Brake Line Installation Error

    New Flyer is recalling 119 model year 2013 buses because incorrectly installed air lines may cause a loss of service braking, increasing crash risk.

    Product
    NEW FLYER — NEW FLYER XD60, XN40, XDE40, XD40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V591000·2012-12-17

    New Flyer Transit Buses Recalled for Drive Shaft Access Panel Defect

    New Flyer is recalling 2,048 model year 2004-2011 transit buses because the drive shaft access panel may be insufficiently strong or secured, posing an injury risk if the drive shaft fails.

    Product
    NEW FLYER — NEW FLYER DE40LFR, DE40LFA, D40LFR, D60LF
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V518000·2012-10-25

    New Flyer Recalls Transit Buses Due to Parking Brake Fire Risk

    New Flyer is recalling 2010-2012 transit buses because air pressure leaks may cause parking brakes to drag and overheat, potentially resulting in a fire.

    Product
    NEW FLYER — NEW FLYER XDE35, D40LFR, XD35, XDE40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V132000·2012-03-26

    New Flyer XDE40 and XDE35 Buses Recalled for Battery Fire Risk

    New Flyer is recalling certain XDE40 and XDE35 transit buses because debris in the lithium-ion battery system can breach electrical isolation, increasing the risk of a fire.

    Product
    NEW FLYER — NEW FLYER XDE40, XDE35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V002000·2012-01-04

    New Flyer Transit Buses Recalled for Instrument Panel Software Defect

    New Flyer is recalling certain 2009-2012 transit buses because instrument panel software may prevent warning lights from illuminating, potentially causing engine shutdown and loss of propulsion.

    Product
    NEW FLYER — NEW FLYER XD40, XDE40, XD35, XDE35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V431000·2011-08-22

    New Flyer Transit Buses Recalled for Exhaust Clamp Fire Risk

    New Flyer is recalling 78 heavy-duty transit buses equipped with Cummins diesel engines because a T-bolt in the exhaust clamp assembly can fracture, potentially causing a fire or road hazard.

    Product
    NEW FLYER — NEW FLYER DE40LFR, D40LFR, D35LFR, DE60LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·26V644000·2026-10-05

    New Flyer Recalls Buses Due to Hazard Light Indicator Defect

    New Flyer is recalling certain 2013-2027 buses because the instrument panel indicator light may not illuminate when hazard warning lights are active.

    Product
    NEW FLYER — NEW FLYER XE35, XHE40, XN60, XHE60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·21V365000·2021-05-18

    New Flyer Recalls Buses Due to Fuel Rail Leak Fire Risk

    New Flyer is recalling certain 2016-2021 XD and XDE series buses because a fuel rail leak could cause a fire.

    Product
    NEW FLYER — NEW FLYER XD35, XD60, XD40, XDE60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·20V462000·2020-08-06

    New Flyer Recalls Transit Buses Due to Pressure Switch Failure Risk

    New Flyer is recalling 164 transit buses because pressure switches may fail, causing a loss of drive and increasing crash risk.

    Product
    NEW FLYER — NEW FLYER XDE60, XDE40, XDE35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·18V827000·2018-11-22

    New Flyer Bus Recall for Fire Extinguisher Actuator Defect

    New Flyer is recalling certain 2013-2017 buses because a fire extinguisher actuator may fail, preventing the suppression system from discharging during a fire.

    Product
    NEW FLYER — NEW FLYER XN60, XN40, XD40, XDE40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V539000·2017-08-30

    New Flyer Transit Bus Seat Belt Buckle Recall

    New Flyer is recalling 2015-2017 transit buses because the driver's seat belt buckle may be stuck, preventing the belt from latching.

    Product
    NEW FLYER — NEW FLYER MD30, XD40, XN40, MD35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V223000·2016-04-19

    New Flyer Transit Buses Recalled for Rear Door Software Defect

    New Flyer is recalling specific transit buses because a software defect may cause the rear door to open unexpectedly while the bus is moving, increasing injury risk.

    Product
    NEW FLYER — NEW FLYER XN40, XN60, C40LFR, XN35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V038000·2016-01-26

    New Flyer and NABI Buses Recalled for Seat Belt Anchor Defect

    New Flyer is recalling specific 2009-2015 New Flyer and NABI buses because missing welds on seat brackets could allow seat belts to separate during a crash.

    Product
    NEW FLYER — NEW FLYER, NABI DE60LFA, DE40LFA, DE35LF, C35LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V333000·2015-06-01

    New Flyer Transit Bus Recall for Door Software Defect

    New Flyer is recalling specific transit buses because a software defect may cause rear doors to open while the bus is moving.

    Product
    NEW FLYER — NEW FLYER XDE35, XN40, XN60, C40LFR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V221000·2013-05-28

    New Flyer Transit Buses Recalled for Defective Push-to-Start Switches

    New Flyer is recalling certain 2012-2013 transit buses because a weak spring in the push-to-start switch may allow the engine to start unexpectedly, posing an injury risk to nearby workers.

    Product
    NEW FLYER — NEW FLYER XD40, XN40, XD35, XD60
    Category
    Vehicle
    Distribution
    Distributed nationwide