  • Severity pendingNHTSA·18V826000·2018-11-21

    Navistar Recalls 2018-2019 International Trucks for Clutch Assembly Defect

    Navistar is recalling certain 2018-2019 International trucks because a clutch component may fail, causing unintended vehicle movement and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL RH, MV, LONESTAR, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V575000·2017-09-20

    2016 International Commercial Vehicles Recalled for Steering Tie Rod Defect

    Navistar is recalling 2016 International and IC Bus vehicles because a steering axle nut may not be properly torqued, risking loss of steering.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS DURASTAR, LONESTAR, PROSTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V776000·2015-11-20

    Navistar Recalls 2013-2014 International Trucks for Accelerator Pedal Defect

    Navistar is recalling 2013-2014 International trucks because a faulty accelerator pedal sensor can cause high engine idle, increasing crash risk on downgrades.

    Product
    INTERNATIONAL — INTERNATIONAL TRANSTAR, DURASTAR, WORKSTAR, LONESTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V755000·2015-11-16

    Navistar Recalls 2014-2015 International TranStar Trucks for Fire Risk

    Navistar is recalling 2014-2015 International TranStar trucks because a turbocharger oil line may leak near the exhaust, increasing fire risk.

    Product
    INTERNATIONAL — INTERNATIONAL TRANSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V438000·2015-07-08

    Navistar Recalls 2013-2015 International TranStar Trucks for Fire Risk

    Navistar is recalling 2013-2015 International TranStar vehicles because a vent tube may detach, allowing engine oil to contact hot surfaces and cause a fire.

    Product
    INTERNATIONAL — INTERNATIONAL TRANSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V241000·2015-04-22

    Navistar Recalls 2011-2015 Commercial Vehicles for HVAC Fire Risk

    Navistar is recalling 82,736 commercial vehicles because an electrical issue in the HVAC system could cause a fire.

    Product
    IC BUS — IC BUS, INTERNATIONAL AC, TRANSTAR, HC, ICSB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·15V165000·2015-03-23

    Navistar Recalls 2015-2016 International Trucks Due to Brake Fire Risk

    Navistar is recalling 2015-2016 International and IC Bus vehicles because defective brake actuators may cause dragging, overheating, and wheel end fires.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS TRANSTAR, CE, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V606000·2014-09-29

    Navistar Recalls 2015 International TranStar Trucks for Clutch Nut Issue

    Navistar is recalling 78 model year 2015 International TranStar vehicles because a clutch rod nut may be missing or loose, which could cause the vehicle to lunge unexpectedly and increase crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL TRANSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V201000·2014-04-17

    Navistar Recalls 2013-2015 International Trucks Due to Brake Caliper Bolt Defect

    Navistar is recalling certain 2013-2015 International DuraStar, WorkStar, ProStar, and TranStar trucks because brake caliper bolts may be missing or improperly torqued, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, WORKSTAR, PROSTAR, TRANSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·14V238000·2014-04-03

    Navistar Recalls 2014 International TranStar Trucks Due to Fire Risk

    Navistar is recalling 2014 International TranStar trucks with specific Cummins engines because condensation may freeze and cause exhaust flames or fire.

    Product
    INTERNATIONAL — INTERNATIONAL TRANSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V439000·2013-09-18

    Navistar Recalls 2008-2013 International Trucks Due to Air Line Assembly Error

    Navistar is recalling 2008-2013 International LoneStar, ProStar, and TranStar trucks because an assembly error in the air lines may cause the fifth wheel jaw to release unexpectedly, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL TRANSTAR, LONESTAR, PROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V546000·2012-11-21

    Navistar Recalls 2012-2013 International Trucks Due to Brake Bracket Fracture Risk

    Navistar is recalling 2012-2013 International ProStar and TranStar trucks because front brake bracket assemblies may fracture, potentially causing brake failure and increased crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL TRANSTAR, PROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V403000·2012-08-14

    Navistar Recalls 2011-2013 International Trucks for Brake Caliper Bolt Defect

    Navistar is recalling certain 2011-2013 International trucks because brake caliper bolts may be loose, increasing stopping distance or causing a pull during braking.

    Product
    INTERNATIONAL — INTERNATIONAL WORKSTAR, TRANSTAR, PROSTAR, DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V196000·2012-05-02

    Navistar Recalls International Trucks Due to Alternator Cable Fire Risk

    Navistar is recalling certain 2010-2013 International trucks because an alternator cable may chafe a power steering hose, causing an electrical short and potential fire.

    Product
    INTERNATIONAL — INTERNATIONAL PAYSTAR, TRANSTAR, PROSTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·12V052000·2012-02-13

    Navistar Recalls International Trucks and Buses for Brake Valve Defect

    Navistar is recalling certain 2011-2013 International trucks and IC Buses because Bendix relay valves may leak in cold weather, causing continuous brake application and fire risk.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS 9200, CE-C, 9800, PAYSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V426000·2011-08-17

    Navistar Recalls 2010-2012 International Trucks Due to Fire Risk

    Navistar is recalling 2010-2012 International commercial trucks because an alternator cable may chafe a power steering hose, causing an electrical short and potential fire.

    Product
    INTERNATIONAL — INTERNATIONAL WORKSTAR, PAYSTAR, TRANSTAR, PROSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·23V248000·2023-04-06

    Navistar Recalls International Buses Due to HVAC Wiring Fire Risk

    Navistar is recalling 2016-2020 International and IC Bus models because an HVAC wiring terminal may overheat, increasing the risk of a fire.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS TRANSTAR, DURASTAR, PROSTAR, LONESTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·17V792000·2017-12-11

    Navistar Recalls International Trucks Due to Fire Extinguisher Defect

    Navistar is recalling specific International trucks because the installed fire extinguishers may clog, require excessive force to activate, or detach, potentially causing injury or failing to suppress a fire.

    Product
    INTERNATIONAL — INTERNATIONAL DURASTAR, 9100I, 4900, 4700
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·16V938000·2016-12-28

    Navistar Recalls 2017 International Trucks Due to Battery Latch Fire Risk

    Navistar is recalling 2017 International ProStar, LoneStar, 9900i, and TranStar trucks because a battery latch may cause an electrical short and fire.

    Product
    INTERNATIONAL — INTERNATIONAL PROSTAR, LONESTAR, 9900I, TRANSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·13V146000·2013-04-17

    Navistar Recalls International Trucks Due to Sun Shade Separation Risk

    Navistar is recalling certain 2011-2013 International commercial trucks because sun shades may separate from the roof, potentially distracting the driver and increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL LONESTAR, PROSTAR, DURASTAR, WORKSTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • Severity pendingNHTSA·11V252000·2011-04-19

    Navistar Recalls 2011-2012 International Trucks for Brake System Defect

    Navistar is recalling certain 2011-2012 International commercial trucks because the trailer ABS fault indicator lamp may fail to illuminate, potentially increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL PAYSTAR, LONESTAR, PROSTAR, DURASTAR
    Category
    Vehicle
    Distribution
    Distributed nationwide