The Recall Desk

State

Utah product recalls

73,912 recalls have nationwide distribution and so reach Utah. 4,919 additional recalls listed Utah specifically in their distribution scope.

What the numbers show

Total
4,919
Critical
524
Severe
1,353
Most recent
2026-11-11

Of the 4,919 recalls naming Utah we have scored against our rubric, 524 (11%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,353 (28%) are Severe.

These figures cover only the 4,919 recalls whose distribution notice names Utah specifically. The 73,912 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

71826–71850 of 78831

  • SevereNHTSA·12V101000·2012-03-14

    Volvo Recalls 2012 S60 and XC60 for Fuel Line Fire Risk

    Volvo is recalling 2012 S60 and XC60 vehicles because underbody coating may damage fuel lines, causing leaks and increasing fire risk.

    Product
    VOLVO — VOLVO S60, XC60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·12V102000·2012-03-14

    Nissan Titan Recall: Incorrect Tire Placard Seating Capacity Information

    Nissan is recalling certain 2012 Titan vehicles with the Sports Appearance Package because the tire placard displays incorrect seating capacity information, which may lead to vehicle overloading.

    Product
    NISSAN — NISSAN TITAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12131·2012-03-13

    Guidecraft Recalls 4-in-1 Play Theaters Due to Tip-Over Hazard

    Guidecraft is recalling 4-in-1 Dramatic Play Theater Toys because they can tip over, posing an entrapment hazard to young children.

    Product
    4-in-1 Dramatic Play Theater Toys
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V100000·2012-03-13

    Trans Tech Horizon Transit Bus Seat Belt Anchor Recall

    Two 2011 Trans Tech Horizon buses are recalled because seat belt anchorages may not meet federal safety standards, increasing injury risk in a crash.

    Product
    TRANS TECH — TRANS TECH HORIZON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V099000·2012-03-13

    Subaru Forester Recall for Rear Center Seat Belt Defect

    Subaru is recalling 2009-2012 Foresters because the rear center seat belt may not secure child restraints properly, increasing injury risk in a crash.

    Product
    SUBARU — SUBARU FORESTER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12132·2012-03-13

    Hydro-Gear Recalls Lawn Tractors Due to Brake Failure Crash Hazard

    Hydro-Gear is recalling about 2,700 Cub Cadet, MTD Gold, and Troy-Bilt lawn tractors because a drive gear failure can cause brake failure, posing a crash hazard.

    Product
    Lawn Tractors
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V096000·2012-03-08

    Mack LEU and MRU Trucks Recalled for Electrical Fire Risk

    Mack is recalling 318 natural gas LEU and MRU trucks because an alternator ground cable defect may cause a vehicle fire during an electrical short.

    Product
    MACK — MACK LEU, MRU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·12129·2012-03-08

    Lenovo Recalls ThinkCentre Desktop Computers Due to Fire Hazard

    Lenovo is recalling about 50,500 ThinkCentre M70z and M90z desktop computers because a power supply defect can overheat and cause a fire.

    Product
    Lenovo ThinkCentre M70z and M90z desktop computers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V097000·2012-03-07

    Ford Recalls 2011 F-650 and F-750 Trucks for Brake Valve Defect

    Ford is recalling 2011 F-650 and F-750 trucks because a brake valve may leak in cold weather, causing continuous braking and potential fire.

    Product
    FORD — FORD F-650, F-750
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V092000·2012-03-07

    Toyota Recalls 2005-2009 Tacoma for Air Bag Cable Defect

    Toyota is recalling 2005-2009 Tacoma vehicles because steering wheel vibration may damage the cable powering the driver's air bag, potentially preventing deployment in a crash.

    Product
    TOYOTA — TOYOTA TACOMA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12128·2012-03-07

    Locker Brand Recalls Rx Lockers Due to Unauthorized Access Risk

    Locker Brand is recalling Rx Lockers because the latch can be forced open, allowing unauthorized access to medicine. No injuries have been reported.

    Product
    Medicine Bottle Storage Containers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·12726·2012-03-07

    BCI Burke Swing Sets Recalled for Fall Hazard

    BCI Burke is recalling about 250 Arch Swing Sets because a welded joint can crack, causing the swing beam to collapse and children to fall.

    Product
    2 3/8 inch Arch Swing Sets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V093000·2012-03-07

    GM Recalls 2012 Buick Regal for Parking Lamp Software Error

    General Motors is recalling 2012 Buick Regal vehicles because a software error prevents parking lamps from activating, reducing visibility.

    Product
    BUICK — BUICK REGAL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·12V094000·2012-03-07

    Cruiser RV Recalls 2013 Enterra Models for Incorrect Federal ID and Tire Labels

    Cruiser RV is recalling 47 model year 2013 Enterra recreational vehicles because incorrect Federal ID and tire labels may lead to improper tire usage and increased crash risk.

    Product
    CRUISER RV — CRUISER RV ENTERRA E314RES, ENTERRA E303BHS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V090000·2012-03-06

    Trans Tech SST School Buses Recalled for Seat Belt Defect

    Trans Tech is recalling 2011-2012 SST school buses because seat belt anchorages may not meet federal safety standards, increasing injury risk in a crash.

    Product
    TRANS TECH — TRANS TECH SST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·12125·2012-03-06

    Gore Recalls Bicycle Brake Cables Due to Fall Hazard

    W.L. Gore & Associates is recalling specific bicycle brake cables that may detach from Campagnolo-style levers, causing brake failure and a fall hazard.

    Product
    Bicycle Brake Cables for Road Bikes
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·12V088000·2012-03-06

    Nissan Recalls 2003-2004 Infiniti M45 for Fuel Gauge Circuit Board Failure

    Nissan is recalling 2003-2004 Infiniti M45 vehicles because a circuit board failure may cause the fuel gauge to read higher than the actual fuel level, potentially leading to the vehicle stalling without warning.

    Product
    INFINITI — INFINITI M45
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V084000·2012-03-05

    Peterson Recalls 2012 Excel Limited RVs for Brake Actuator Defect

    Peterson Industries is recalling 2012 Excel Limited recreational vehicles because improperly heat-treated brake actuator pumps may fail, increasing crash risk.

    Product
    EXCEL — EXCEL LIMITED
    Category
    Vehicle
    Distribution
    Distributed nationwide