The Recall Desk

State

Colorado product recalls

72,969 recalls have nationwide distribution and so reach Colorado. 6,941 additional recalls listed Colorado specifically in their distribution scope.

What the numbers show

Total
6,941
Critical
1,218
Severe
1,507
Most recent
2026-09-09

Of the 6,941 recalls naming Colorado we have scored against our rubric, 1,218 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,507 (22%) are Severe.

These figures cover only the 6,941 recalls whose distribution notice names Colorado specifically. The 72,969 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

5626–5650 of 79910

  • HighFDA (Devices)·Z-2503-2025·2025-09-10

    Interventional imaging systems recalled because single phase UPS may fail on power loss

    Philips Allura systems configured with a 1 Phase UPS are recalled because they may shut down and/or fail to start up if power to the system is lost. 1,006 units are affected.

    Product
    Philips Allura System configured with a 1 Phase UPS. Allura family (R1.x, R2.x). Labeled as the following with corresponding model numbers: 1. Allura Xper FD10, Model Number 722003 2. Allura Xper FD10/10, Model Number 722005 3. Allura Xper FD20, Model Number 722006
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2507-2025·2025-09-10

    MediHoney HCS sheet dressings recalled over packaging failures breaching sterility

    MediHoney HCS Sheet Dressings, catalog numbers 31612, 31622 and 31644, are recalled after packaging failures were identified that could breach the sterile barrier. 3,583 units are affected.

    Product
    Brand Name: MediHoney¿ Product Name: MediHoney¿ HCS Sheet Dressing with Leptospermum Model/Catalog Number: 31612, 31622, 31644 Product Description: MEDIHONEY¿ HCS SHEET DRESSING with LEPTOSPERMUM HONEY is a moist wound dressing made of Leptospermum Honey (+15) in combination w
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2521-2025·2025-09-10

    Tumor profiling assay recalled after incorrect result gave wrong therapy recommendation

    One MI Cancer Seek tumor mutational profiling assay is recalled because an incorrect test result was provided that indicated the incorrect drug therapy recommendation.

    Product
    MI Cancer Seek REF MSC000 UDI Code: (01)00860008613325(21)H5HJHDSXF MI Cancer Seek is a single-site assay intended to provide tumor mutational profiling to be used by qualified healthcare professionals in accordance with professional oncology guidelines for cancer patients wi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2502-2025·2025-09-10

    Azurion imaging systems recalled because single phase UPS may fail on power loss

    Philips Azurion systems configured with a 1 Phase UPS are recalled because they may shut down and/or fail to start up if power to the system is lost. 1,861 units are affected.

    Product
    Philips Azurion System configured with a 1 Phase UPS. Azurion family (R1.x, R2.x). Labeled as the following with corresponding model numbers: 1. Azurion 3 M12, Model Number 722063. 2. Azurion 3 M15, Model Number 722064. 3. Azurion 7 B12, Model Number 722067. 4. Az
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2510-2025·2025-09-10

    MediHoney hydrogel adhesive sheets recalled over sterile barrier packaging failures

    MediHoney Hydrogel Adhesive Sheet dressings, catalog numbers 31722 and 31744, are recalled after packaging failures were identified that could breach the sterile barrier. 1,147 units are affected.

    Product
    Brand Name: MediHoney¿ Product Name: MediHoney¿ Hydrogel Adhesive Sheet Model/Catalog Number: 31722, 31744 Product Description: MEDIHONEY¿ HCS ADHESIVE SHEET DRESSING with LEPTOSPERMUM HONEY is a moist wound dressing made of Leptospermum Honey (+15) in combination with a hydro
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2520-2025·2025-09-10

    Surgical drape packs recalled because open seals may compromise sterility

    Orthopedic Pack model 88041-12 and Universal Pack model 77165-06 are recalled because the surgical drape packs may have open seals that could compromise sterility. 1,316 units are affected.

    Product
    Orthopedic Pack, Model: 88041-12 AC2424601B 09/02/2029 Universal Pack, Model: 77165-06 AC2424902B 09/05/2029
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2486-2025·2025-09-10

    Radiotherapy systems recalled over software allowing more than two daily fractions

    RefleXion X1 systems are recalled because an incorrect software configuration potentially allows more than two treatment fractions within a 12-hour period, which could lead to toxicity. 11 units are affected.

    Product
    RefleXion X1 Model RXM1000 UDI Codes: (01)00860003983812(11)230504(21)X11001 (01)00860003983812(11)230518(21)X11002 (01)00860003983812(11)230505(21)X11003 (01)00860003983812(11)230530(21)X11004 (01)00860003983812(11)230811(21)X11006 (01)00860003983812(11)230410(21)X11007
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2500-2025·2025-09-10

    Uric acid meter kits recalled for distribution without premarket clearance

    Blood Uric Acid Monitoring System kits, model eB-U01, are recalled because the products were distributed without premarket clearance or approvals. 2,240 units are affected.

    Product
    Blood Uric Acid Monitoring System Each kit contains 1 meter, 1 lancing device, user manual, 10 lancets, and 10 test strips (10-count bottle)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2498-2025·2025-09-10

    LIFEPAK 1000 defibrillators recalled over inspections missed after unit servicing

    Three LIFEPAK 1000 defibrillators are recalled because required inspections were not performed on units that had gone through servicing.

    Product
    LIFEPAK 1000 Part / Catalog Numbers / UDI-DI code: 320371500023 / 99425-000025 / 885074698953 320371500229 / 99425-000025 / 885074698953 331706400001 / 99425-000025 / 885074698953 LIFEPAK 1000: The defibrillator is to be used in AED mode only on patients who are in cardio
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2493-2025·2025-09-10

    RayStation 12A planning software recalled over duplicate DICOM instance identifier risk

    RayStation 12A and its service packs are recalled because DICOM instance identifiers from the RayGateway interface to Accuray's iDMS are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 12A, Software Version: 13.0.0.1547. 2. RayStation 12A Service Pack 1, Software Version: 13.1.0.144. 3. RayStation 12A Service Pack 2, Software Version: 13.1.1.89. Product Description: Radiation Thera
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2501-2025·2025-09-10

    Uric acid monitoring kits recalled over missing premarket clearance or approval

    A second lot group of Blood Uric Acid Monitoring System kits, model eB-U01, covering all lots made up to June 20, 2022, is recalled for distribution without premarket clearance. 2,580 units are affected.

    Product
    Blood Uric Acid Monitoring System Each kit contains 1 meter, 1 lancing device, user manual, 10 lancets, and 10 test strips (10-count bottle)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0619-2025·2025-09-10

    Chlorpromazine 200 mg tablets recalled over micro-organism on packaging component

    Amneal chlorpromazine hydrochloride tablets, 200 mg, are recalled because a micro-organism was detected on a lot of auxiliary polyester coil used in packaging. No micro-organism was found on any tablets.

    Product
    CHLORPROMAZINE HYDROCHLORIDE — CHLORPROMAZINE HYDROCHLORIDE (CHLORPROMAZINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2495-2025·2025-09-10

    RayStation 2023B and 2024A software recalled over non-unique DICOM identifiers

    RayStation 2023B, 2024A and 2024A SP3 radiation therapy planning software is recalled because DICOM instance identifiers from the RayGateway interface are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 2023B, Software Version: 14.0.0.3338. 2. RayStation 2024A, Software Version: 15.0.0.430. 3. RayStation 2024A SP3, Software Version: 15.1.3.10. Product Description: Radiation Therapy Treatment Plannin
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0616-2025·2025-09-10

    Chlorpromazine 25 mg tablets recalled after micro-organism found on packaging coil

    Amneal chlorpromazine hydrochloride tablets, 25 mg, are recalled because a micro-organism was detected on a lot of auxiliary polyester coil used in packaging. No micro-organism was found on any tablets.

    Product
    CHLORPROMAZINE HYDROCHLORIDE — CHLORPROMAZINE HYDROCHLORIDE (CHLORPROMAZINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2494-2025·2025-09-10

    RayStation 6 service packs recalled over DICOM identifier uniqueness defect

    RayStation 6 Service Packs 1, 2 and 3 radiation therapy planning software is recalled because DICOM instance identifiers from the RayGateway interface are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 6 Service Pack 1, Software Version: 6.1.1.2. 2. RayStation 6 Service Pack 2, Software Version: 6.2.0.7. 3. RayStation 6 Service Pack 3, Software Version: 6.3.0.6. Product Description: Radiation Thera
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2514-2025·2025-09-10

    Dental titanium bases recalled because the post is oriented 180 degrees off

    NobelBiocare Tri-Lobe-compatible WP 6.0mm engaging titanium bases, lot 277097, are recalled because the base was manufactured 180 degrees around the post from the correct position. 11 units are affected.

    Product
    NobelBiocare Tri-Lobe-compatible WP X 6.0mm Engaging Titanium Base, REF: 9000662
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2489-2025·2025-09-10

    RayStation 9B and 10A software recalled over non-unique DICOM identifiers

    RayStation 9B, 9B SP1, 10A and 10A service pack radiation therapy planning software is recalled because DICOM instance identifiers from the RayGateway interface are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 9B, Software Version: 9.1.0.933. 2. RayStation 9B Service Pack 1, Software Version: 9.2.0.483. 3. RayStation 10A, Software Version: 10.0.0.1154. 4. RayStation 10A Service Pack 1, Software Version: 10.0
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2516-2025·2025-09-10

    Spinal implant inserters recalled over potential missing pins at the tip

    TOPS Inserters, model 82889, part of the TOPS System Instrument Set, are recalled because of the potential for missing pins at the tip of the inserter. 30 units are affected.

    Product
    TOPS Inserter, part of the TOPS System Instrument Set used for implantation of the TOPS System. Model Number: 82889.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2497-2025·2025-09-10

    LIFEPAK 15 defibrillators recalled because post-service inspections were not performed

    Four LIFEPAK 15 defibrillators are recalled because required inspections were not performed on units that had gone through servicing.

    Product
    LIFEPAK 15 Part / Catalog Numbers / UDI-DI code: V15-7-000022 / 99577-001957 / 883873871690 V15-2-000051 / 99577-000046 / 883873988022 V15-2-000099 / 99577-000093 / 883873979020 V15-2-001603 / 99577-001256 / 883873911631 LIFEPAK 15: The LP15 is intended for use by trained
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2491-2025·2025-09-10

    RayStation 11A planning software recalled over non-unique DICOM instance identifiers

    RayStation 11A and its service packs are recalled because DICOM instance identifiers from the RayGateway interface to Accuray's iDMS are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 11A, Software Version: 11.0.0.951. 2. RayStation 11A Service Pack 1, Software Version: 11.0.1.29. 3. RayStation 11A Service Pack 2, Software Version: 11.0.3.116. 4. RayStation 11A Service Pack 3, Softw
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2487-2025·2025-09-10

    RayStation 7 and 8A software recalled over DICOM instance identifier defect

    RayStation 7, 8A and 8A Service Pack 1 radiation therapy planning software is recalled because DICOM instance identifiers from the RayGateway interface are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 7, Software Version: 7.0.0.19. 2. RayStation 8A, Software Version: 8.0.0.61. 3. RayStation 8A Service Pack 1, Software Version: 8.0.1.10. Product Description: Radiation Therapy Treatment Planning Sys
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2490-2025·2025-09-10

    RayStation 10B planning software recalled over DICOM identifiers not guaranteed unique

    RayStation 10B and 10B Service Pack 1 radiation therapy treatment planning software is recalled because DICOM instance identifiers from the RayGateway interface are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 10B, Software Version: 10.1.0.613. 2. RayStation 10B Service Pack 1, Software Version: 10.1.1.54. Product Description: Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2488-2025·2025-09-10

    RayStation 8B and 9A software recalled over DICOM identifier uniqueness defect

    RayStation 8B, its service packs and 9A radiation therapy planning software is recalled because DICOM instance identifiers from the RayGateway interface are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 8B, Software Version: 8.1.0.47. 2. RayStation 8B Service Pack 1, Software Version: 8.1.1.8. 3. RayStation 8B Service Pack 2, Software Version: 8.1.2.5. 4. RayStation 9A, Software Version: 9.0.0.113.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2499-2025·2025-09-10

    Defibrillator recalled because required post-service inspections were not performed

    One LIFEPAK CR2 defibrillator is recalled because required inspections were not performed on units that had gone through servicing.

    Product
    LIFEPAK CR2 Part / Catalog Numbers / UDI-DI code: CR2-2-001451 99512-001434 883873785911 LIFEPAK CR2: The LIFEPAK CR2 defibrillator is indicated for use on patients 1 year of age or older in cardiopulmonary arrest. The patient must be unresponsive (unconscious), not breathin
    Category
    Medical Device
    Distribution
    Distributed nationwide