The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

4851–4875 of 9745

  • HighCPSC·11024·2010-10-27

    Primal Vantage Recalls Plastic Tree Steps Due to Fall Hazard

    Primal Vantage is recalling Ameristep Plastic Strap-On Tree Steps because the plastic portion can break, posing a fall hazard to users.

    Product
    Ameristep Plastic Strap-On Tree Step
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·11706·2010-10-27

    John Deere Zero-Turn Mowers Recalled Due to Steering Lock Hazard

    John Deere is recalling about 6,450 zero-turn mowers and 300 foot lift kits because a bolt can lock the steering lever, posing an injury risk.

    Product
    John Deere EZtrak Zero Turn Lawn Mowers with Foot Lift and Zero Turn Mowers with Premium Foot Lift Kit
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·11023·2010-10-27

    Meijer Recalls Falls Creek Infant Boy Shoes Due to Choking Hazard

    Meijer is recalling about 2,300 Falls Creek infant boy shoes because the lace toggles can detach, posing a choking hazard to young children.

    Product
    Falls Creek infant boy shoes
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·11022·2010-10-26

    GE Recalls Profile and Monogram Dishwashers Due to Fire Hazard

    GE is recalling about 174,000 Profile and Monogram dishwashers because water condensation can cause a short circuit and fire. Consumers should stop using the units and contact GE for a repair or rebate.

    Product
    GE Profile™ and GE Monogram® Dishwashers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·11020·2010-10-22

    Victory Land Group Recalls Heritage Drop-Side Cribs for Entrapment Hazards

    Victory Land Group is recalling Heritage Collection drop-side cribs sold at Kmart because the drop-side rail can detach, creating a risk of infant entrapment, suffocation, or falls.

    Product
    Heritage Collection 3-in-1 drop-side cribs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·11016·2010-10-21

    Frigidaire and Electrolux Smoothtop Cooktops and Ranges Recalled for Fire Hazard

    Electrolux is recalling about 122,000 Frigidaire and Electrolux ICON smoothtop cooktops and slide-in ranges because liquids can pool under control knobs, causing unexpected heating and fire risks.

    Product
    Frigidaire and Electrolux ICON Smoothtop Electric Cooktops and Frigidaire Slide-in Ranges with rotary knobs and digital displays
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·11705·2010-10-21

    Kohler Recalls Frameless Bath Doors Due to Laceration Hazard

    Kohler is recalling specific frameless by-pass bath doors sold at Lowe's and Home Depot because the glass can shatter, posing a laceration hazard.

    Product
    Kohler and Sterling Frameless by-pass bath doors
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·11015·2010-10-20

    Graco Recalls Quattro and MetroLite Strollers Due to Entrapment Risk

    Graco is recalling Quattro and MetroLite strollers because infants can become entrapped in the gap between the tray and seat, posing a strangulation risk.

    Product
    Graco Quattro Tour™ and MetroLite™ strollers and travel systems
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·11012·2010-10-18

    Munchkin Bathtub Submarine Toys Recalled for Laceration Risk

    Munchkin is recalling about 34,000 Bathtub Subs toys because the intake valve can suck up loose skin, posing a laceration hazard to children.

    Product
    Bathtub Subs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·11011·2010-10-15

    JAKKS Pacific Recalls Spa Factory Kits Due to Explosion and Projectile Hazards

    JAKKS Pacific is reannouncing a recall of Spa Factory Aromatherapy Fountain and Bath Benefits Kits because unvented jar caps can explode, causing injuries and property damage.

    Product
    Spa Factory™ Aromatherapy Fountain & Bath Benefits Kits
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·11009·2010-10-14

    Ryobi Cordless Drills Recalled Due to Fire and Burn Hazards

    Ryobi is recalling about 455,000 Model HP 1802M cordless drills because the switch can overheat, posing a fire and burn hazard.

    Product
    Ryobi Model HP 1802M Cordless Power Drills
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·11010·2010-10-14

    The Hive Recalls Revl Carbon Road Bicycle Brakes Due to Fall Hazard

    The Hive is recalling about 500 Revl carbon road bicycle brakes because the cable clamping area can crack, causing brake failure and posing a fall hazard.

    Product
    Revl carbon bicycle brakes
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·11008·2010-10-13

    Ross Stores Recalls Iron Lover's Benches Due to Fall Hazard

    Ross Stores is recalling about 185 Iron Lover's benches because they can tip over when one person sits on them, posing a fall hazard.

    Product
    Iron Lover's benches
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·10E049000·2010-10-08

    Norcold Recalls RV Refrigerators Due to Fire Risk

    Norcold is recalling specific gas absorption refrigerators for recreational vehicles because their safety sensors may not shut off power quickly enough to prevent a fire.

    Product
    EQUIPMENT recall
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereCPSC·11006·2010-10-07

    Bravo Sports Recalls Trampolines Due to Fall Hazard

    Bravo Sports is recalling approximately 160,000 trampolines because incorrectly assembled units may bend or break, posing a fall hazard.

    Product
    Bravo Sports Trampolines
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·11005·2010-10-07

    Alexander Designs Drop-Side Cribs Recalled for Entrapment and Fall Hazards

    JCPenney recalled about 11,400 Alexander Designs drop-side cribs because the drop-side rail can detach, creating gaps that risk infant entrapment, suffocation, or falls.

    Product
    Alexander Designs Ltd. brand drop-side cribs
    Category
    Consumer Product
    Distribution
    Distributed nationwide