The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

1576–1600 of 15247

  • HighNHTSA·25V064000·2025-02-06

    2025 Hyundai Ioniq 5 rear side air bag deployment failure recall

    Hyundai is recalling certain 2025 Ioniq 5 electric vehicles because the rear floor wiring harness may contain an open circuit, preventing the rear side air bag from deploying as intended and increasing injury risk in a crash.

    Product
    HYUNDAI — HYUNDAI IONIQ 5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V059000·2025-02-06

    2025 Lexus NX vehicles recalled for damaged rear seat belt webbing

    Toyota is recalling certain 2025 Lexus NX and other vehicles because the second-row center seat belt webbing may be damaged, potentially reducing occupant restraint in a crash.

    Product
    LEXUS — LEXUS, TOYOTA NX, RX, NX HYBRID, RX HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25E009000·2025-02-06

    Firefly Integrations Recalls Thor Motor Coach G12 Electronic Control Modules

    Firefly Integrations is recalling specific G12 Electronic Control Modules installed in Thor Motor Coach vehicles due to a software error that may allow the awning to extend while driving.

    Product
    EQUIPMENT:RECREATIONAL VEHICLE/TRAILER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25E007000·2025-02-05

    Samsung SDI Recalls High-Voltage Battery Packs for Multiple Vehicle Brands

    Samsung SDI is recalling high-voltage battery packs installed in Chrysler, Volkswagen/Audi, and Ford vehicles because they may fail, increasing the risk of a crash or fire.

    Product
    ELECTRICAL SYSTEM:PROPULSION SYSTEM:TRACTION BATTERY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V056000·2025-02-05

    2025 Honda Pilot third-row seat belt may not restrain occupant

    Honda is recalling certain 2025 Pilot vehicles because the third-row passenger seat belt may not function due to incorrect routing. A non-functioning seat belt cannot properly restrain occupants, increasing injury risk during a crash.

    Product
    HONDA — HONDA PILOT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V054000·2025-02-04

    Highland Ridge Recalls 2025 Open Range 3X Trailers for Incorrect Tire Labeling

    Highland Ridge RV is recalling 2025 Open Range 3X fifth-wheel travel trailers because the vehicle certification label lists the wrong tire size, which could lead to incorrect tire installation.

    Product
    HIGHLAND RIDGE FW — HIGHLAND RIDGE FW OPEN RANGE 3X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V053000·2025-02-03

    New Flyer Transit Buses Recalled for Fuel Hose Separation Risk

    New Flyer is recalling 210 transit buses because fuel filter hoses may separate, causing leaks, engine stalls, and fire risks.

    Product
    NEW FLYER — NEW FLYER XDE60, XD35, XD40, XD60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V052000·2025-02-03

    Temsa Recalls 2024 TS35 Vehicles Due to Fuel Hose Separation Risk

    Temsa is recalling 2024 TS35 vehicles with Cummins L9 engines because fuel filter hoses may separate, causing leaks, engine stalls, and fire or crash risks.

    Product
    TEMSA — TEMSA TS35
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V051000·2025-01-31

    Roadtrek Recalls Westfalia Wave Vans Due to Incorrect Weight Labels

    Roadtrek is recalling 2023-2025 Westfalia Wave Pop Top vans because incorrect weight labels may lead to unintentional overloading and increased crash risk.

    Product
    ROADTREK — ROADTREK WESTFALIA WAVE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V048000·2025-01-31

    Ford and Lincoln rearview cameras may show blank or distorted images

    Ford is recalling certain 2021 Expedition, 2021-2022 Super Duty F-250 to F-600 and 2020-2022 Lincoln Corsair vehicles because the rearview camera may display a blank or distorted image.

    Product
    FORD — FORD, LINCOLN F-250 SD, F-550 SD, F-450 SD, F-350 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V049000·2025-01-31

    Ford Recalls 2025 Models for Instrument Panel Illumination Defect

    Ford is recalling 2025 Bronco Sport, Escape, and Lincoln Corsair vehicles because the instrument panel may fail to illuminate, increasing crash risk.

    Product
    FORD — FORD, LINCOLN BRONCO SPORT, ESCAPE, CORSAIR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V045000·2025-01-30

    Autocar Recalls 2023-2025 E-ACTT Vehicles Due to Software Error

    Autocar is recalling 2023-2025 E-ACTT vehicles because a software error may cause the vehicle to roll away on an incline or stall the engine.

    Product
    AUTOCAR — AUTOCAR E-ACTT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V042000·2025-01-30

    Brinkley fifth wheel solar charge controllers can fail and overheat

    Brinkley RV is recalling certain 2024-2025 Model G fifth wheel trailers because the solar charge controller may fail and overheat, increasing the risk of fire.

    Product
    BRINKLEY RV — BRINKLEY RV MODEL G
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V043000·2025-01-30

    Jayco Recalls 2025 Jay Feather Micro Trailers Due to Gas Leak Risk

    Jayco is recalling 2025 Jay Feather Micro trailers because a cracked burner tube may cause a gas leak, increasing fire risk.

    Product
    JAYCO TRAVEL TRAILER — JAYCO TRAVEL TRAILER JAY FEATHER MICRO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V040000·2025-01-29

    Toyota and Lexus spiral cable fault can deactivate the driver airbag

    Toyota is recalling certain 2023-2024 Toyota and Lexus vehicles that may have been incorrectly repaired under recall 23V-480, because an insufficiently welded connection can deactivate the driver's airbag.

    Product
    LEXUS — LEXUS, TOYOTA RX, HIGHLANDER, COROLLA, NX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V041000·2025-01-29

    Kenworth and Peterbilt lighting switch failure disables hazard lights

    PACCAR is recalling certain 2023-2026 Kenworth and Peterbilt trucks because the exterior lighting switch may fail, leaving the hazard lights and instrument backlight brightness adjustment inoperative.

    Product
    KENWORTH — KENWORTH, PETERBILT T480, T380, T280, 548
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V037000·2025-01-28

    Mitsubishi Fuso Recalls 2024 Rizon Trucks for Wiring Seal Defect

    Mitsubishi Fuso is recalling 233 2024 Rizon trucks because an improperly sealed chassis harness may allow water intrusion, causing loss of drive power and increasing crash risk.

    Product
    MITSUBISHI FUSO — MITSUBISHI FUSO RIZON FEC7K (E16), RIZON FEC9K (E18)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V038000·2025-01-28

    Freightliner chassis fuel filter hoses can separate causing leak and stall

    Daimler Trucks is recalling certain 2022-2025 Freightliner Custom Chassis vehicles with Cummins L9 diesel engines because remote fuel filter hoses may separate from the fitting, causing a fuel leak and engine stall.

    Product
    FCCC — FCCC XCM, XCS, XCR, XBS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V013000·2025-01-24

    Ducati Recalls 2025 Panigale V4 S for Rear Brake Hose Heat Damage

    Ducati is recalling 2025 Panigale V4 S motorcycles because excessive heat may damage the rear brake hose, causing sudden brake loss and increasing crash risk.

    Product
    DUCATI — DUCATI PANIGALE V4 S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25V034000·2025-01-24

    2025 Coachmen Catalina Travel Trailer Recall for Incorrect Weight Label

    Forest River is recalling 2025 Coachmen Catalina travel trailers because the Federal Placard lists an incorrect dry weight, which could lead to unintentional overloading.

    Product
    COACHMEN — COACHMEN CATALINA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V033000·2025-01-23

    Subaru Forester alloy wheels may be improperly attached losing stability

    Subaru is recalling certain 2025 Forester vehicles with 18-inch aluminium alloy wheels because an incorrectly specified lug seat surface can leave the wheel improperly attached.

    Product
    SUBARU — SUBARU FORESTER
    Category
    Vehicle
    Distribution
    Distributed nationwide