The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3226–3250 of 14961

  • HighNHTSA·23V407000·2023-06-06

    Pierce Aerial Ladder Platform Stabilizer Beam Cracks Pose Instability Risk

    Pierce is recalling certain 2016-2022 Ascendant 107' and 110' Platforms with potentially cracked galvanized stabilizer beams that could cause instability when elevated, increasing injury risk.

    Product
    PIERCE — PIERCE LADDER AND PLATFORM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V408000·2023-06-06

    L'AIR Travel Trailer Recall for Potential Gas Leak Fire Risk

    Imagine Fiberglass Products is recalling 2021-2023 L'AIR travel trailers because aluminum burner tubes may fracture, causing a gas leak that could lead to fire.

    Product
    L'AIR CAMPER — L'AIR CAMPER TRILLIUM HERITAGE 1300, TRILLIUM HERITAGE 4500, LION 1300, LION 4500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V405000·2023-06-05

    Mercedes-Benz Recalls EQS and EQE Models for Drivetrain Software Error

    Mercedes-Benz is recalling 8,281 electric vehicles due to a software error that may cause a loss of drive power, increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG EQS, AMG EQE, EQS 580, EQS 450
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V404000·2023-06-05

    2023 Jayco Swift and Entegra Ethos solar panels may detach, creating road hazard

    Jayco is recalling 2023 Swift and Entegra Ethos RVs where solar panels may detach from the roof and become road hazards, increasing crash risk. Dealers will install replacement brackets.

    Product
    ENTEGRA — ENTEGRA, JAYCO ETHOS, ETHOS LI, SWIFT LI, SWIFT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V406000·2023-06-05

    2022-2023 Tiffin motorhomes recalled for loss of chassis power

    Certain 2022-2023 Tiffin motorhomes built on PowerGlide chassis are recalled because a fuse can trip during air conditioning compressor failure, causing loss of power to the chassis and risking engine stall.

    Product
    TIFFIN — TIFFIN ALLEGRO BUS, PHAETON, ZEPHYR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V401000·2023-06-04

    Volvo Recalls 2019-2023 VNR Electric Trucks for Fire Risk

    Volvo Trucks North America is recalling 2019-2023 VNR Electric vehicles because loose power cable connections to the windscreen heater relay may cause a fire.

    Product
    VOLVO — VOLVO VNRE (ELECTRIC)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V402000·2023-06-04

    Mack Recalls 2019-2023 LRBE Electric Trucks for Fire Risk

    Mack is recalling 2019-2023 LRBE electric trucks because loose power cable connections to the windscreen heater relay may cause overheating and increase the risk of a fire.

    Product
    MACK — MACK LRBE (ELECTRIC)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V403000·2023-06-04

    2022-2024 Volvo VNL and VHD trucks: side airbag circuit defect

    Volvo is recalling 2022-2024 VNL and VHD trucks with RollTek driver seats due to a missing circuit that prevents side airbag deployment during a crash, increasing injury risk. Dealers will install a jumper harness for free.

    Product
    VOLVO — VOLVO VHD, VNL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V396000·2023-06-02

    Terex Recalls 2021 TL48 Trucks Due to Subframe Weld Defect

    Terex is recalling 2021 TL48 trucks because a subframe weld defect could cause the aerial device to fall, increasing injury risk.

    Product
    TEREX — TEREX TL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V397000·2023-06-02

    Commercial Buses and Trucks Recalled for Brake Pressure Switch Fire Risk

    Navistar is recalling certain IC BUS and International commercial buses and trucks due to a brake pressure switch defect that may cause electrical short and fire risk. Owners should park vehicles outside until repairs are completed.

    Product
    INTERNATIONAL — INTERNATIONAL, IC BUS MV, DURASTAR, 1300FBC, TC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V398000·2023-06-02

    IC Bus CESB school buses recalled for brake pressure switch fire risk

    Navistar is recalling certain IC Bus CESB school buses with brake pressure switch assemblies that may leak brake fluid and cause electrical short-circuits, creating a fire risk while driving or parked.

    Product
    IC BUS — IC BUS CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V399000·2023-06-02

    Triple E Recalls 2023 Motorhomes Due to Exposed Wiring Fire Risk

    Triple E is recalling 2023 Unity and Wonder motorhomes because a cut air conditioning cable may expose wires to a metal junction box, creating a fire hazard.

    Product
    TRIPLE E RV — TRIPLE E RV, TRIPLE E WONDER, UNITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V400000·2023-06-02

    Commercial trucks: park brake warning light may illuminate incorrectly

    Autocar commercial trucks from 2016-2023 may have a faulty pressure switch causing the park brake warning light to malfunction, increasing crash risk. Dealers will replace the pressure switch at no cost.

    Product
    AUTOCAR — AUTOCAR LEGEND, XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V393000·2023-06-01

    Land Rover Discovery Recall for Rear Door Latch Failure

    Jaguar Land Rover is recalling 2017-2020 Discovery vehicles because rear doors may open while driving, increasing crash risk.

    Product
    LAND ROVER — LAND ROVER DISCOVERY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V391000·2023-06-01

    2023 Entegra Odyssey motorhomes recalled for loose rear axle bolts

    Jayco is recalling certain 2023 Entegra Odyssey motorhomes because bolts securing the rear axle rotor to the wheel hub may be improperly tightened, potentially causing wheel separation and increased crash risk.

    Product
    JAYCO — JAYCO, ENTEGRA REDHAWK, GREYHAWK, ODYSSEY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V392000·2023-06-01

    2023 Subaru Ascent Front Lower Control Arm Separation Recall

    2023 Subaru Ascent vehicles may have improperly tightened ball joint castle nuts in the lower control arm, risking separation and loss of vehicle control. Free replacement at dealers.

    Product
    SUBARU — SUBARU ASCENT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V390000·2023-06-01

    2020-2021 Jayco Melbourne Motorhomes Recalled for Instrument Cluster Failure

    Jayco is recalling certain 2020-2021 Melbourne motorhomes because the instrument cluster may fail and display nothing. Drivers would lose access to critical vehicle information, increasing crash risk.

    Product
    JAYCO — JAYCO MELBOURNE PRESTIGE, MELBOURNE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V395000·2023-06-01

    Altec aerial device trucks: forward collision braking system software miscalibration

    Altec is recalling 2020-2023 aerial device trucks due to collision mitigation system software that may not be calibrated correctly, preventing the active braking system from activating. This increases the risk of a crash.

    Product
    ALTEC — ALTEC AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V394000·2023-06-01

    2022-2023 Land Rover Range Rover Rear Taillight Link Defect Recall

    Land Rover is recalling 2022-2023 Range Rovers because a damaged rear taillight link can cause exterior lights to fail, reducing visibility and increasing crash risk.

    Product
    LAND ROVER — LAND ROVER RANGE ROVER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V388000·2023-05-31

    Bugatti Recalls One 2023 Chiron Super Sport for Incorrect Wheels

    Bugatti is recalling one 2023 Chiron Super Sport because incorrect wheels were installed, which may cause loss of vehicle control in Top Speed Mode.

    Product
    BUGATTI — BUGATTI CHIRON SUPER SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V387000·2023-05-31

    Triple E Recalls 2023 Motorhomes Due to LPG Gas Leak Risk

    Triple E is recalling 2023 Unity and Wonder motorhomes because an improperly crimped 2-stage regulator may cause a gas leak, increasing the risk of fire.

    Product
    TRIPLE E RV — TRIPLE E RV, TRIPLE E WONDER, UNITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V366000·2023-05-31

    Marion Body Works Recalls 2022-2023 Spartan Fire Trucks for Transmission Defect

    Marion Body Works is recalling 2022 Spartan Fire Gladiator and 2023 Spartan Fire MetroStar emergency vehicles because the transmission control module may fail to engage 4th gear lockup, preventing the water pump from starting.

    Product
    MARION BODY WORKS — MARION BODY WORKS SPARTAN FIRE METROSTAR, SPARTAN FIRE GLADIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide