86 recalls in our database name Tesla, Inc. as the manufacturing or recalling firm.

What the numbers show

Total
86
Critical
0
Severe
21
Most recent
2026-08-31

Of the 86 recalls from Tesla, Inc. we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 21 (24%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

26–50 of 86

  • HighNHTSA·24V456000·2024-06-19

    2024 Tesla Cybertruck front windshield wiper motor failure recall

    Tesla is recalling certain 2024 Cybertruck vehicles due to excessive electrical current that can cause the front windshield wiper motor controller to fail, reducing visibility and increasing crash risk.

    Product
    TESLA — TESLA CYBERTRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·24V457000·2024-06-19

    2024 Tesla Cybertruck Trunk Bed Trim Sail Applique Recall

    Tesla is recalling certain 2024 Cybertruck vehicles because the trunk bed trim sail applique may be improperly adhered and can loosen or detach, creating a road hazard.

    Product
    TESLA — TESLA CYBERTRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V376000·2024-05-28

    Tesla seat belt warning light and chime may not activate

    Tesla is recalling certain 2012-2024 vehicles because the seat belt warning light and audible chime may not activate for an unbelted driver, failing FMVSS 208. A free over-the-air update fixes it.

    Product
    TESLA — TESLA MODEL S, MODEL X, MODEL 3, MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V284000·2024-04-19

    2024 Tesla Model 3 Side Air Bag Module Missing Deflector

    Tesla is recalling one 2024 Model 3 vehicle. The driver seat side air bag module was assembled without a deflector, which may cause improper deployment and increase the risk of injury during a crash.

    Product
    TESLA — TESLA MODEL 3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V276000·2024-04-17

    2024 Tesla Cybertruck Accelerator Pedal Dislodgement Recall

    Tesla is recalling certain 2024 Cybertruck vehicles because the accelerator pedal pad may dislodge and become trapped by the interior trim, potentially causing unintended acceleration and crash risk.

    Product
    TESLA — TESLA CYBERTRUCK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V153000·2024-02-27

    Tesla Recalls Vehicles With Muted Pedestrian Warning Sounds

    Tesla is recalling certain 2013-2022 Model S, X, 3, and Y vehicles because a factory reset can mute the Pedestrian Warning System sounds, increasing crash risk for pedestrians.

    Product
    TESLA — TESLA MODEL 3, MODEL Y, MODEL X, MODEL S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·24V051000·2024-01-30

    Tesla brake warning light font size fails federal display standard

    Tesla is recalling certain 2012-2024 vehicles because the Brake, Park and ABS warning lights display at an incorrect font size, failing FMVSS 105 and 135. A free over-the-air update fixes it.

    Product
    TESLA — TESLA MODEL S, MODEL X, MODEL 3, MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V862000·2023-12-19

    2022-2023 Tesla Model S and X Door Latch Safety Defect Recall

    Certain 2022-2023 Tesla Model S and X vehicles may have cabin doors that unlock during a crash due to a door latch defect. Tesla is providing a free over-the-air software update to fix the issue.

    Product
    TESLA — TESLA MODEL S, MODEL X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V838000·2023-12-12

    Tesla Model Y Autosteer Recall: Software Update for Control Prominence

    Tesla is recalling 2.03 million 2012-2023 Model S/X/3/Y vehicles with Autosteer due to insufficient control prominence that may allow driver misuse and crash risk. A free OTA software update will be provided.

    Product
    TESLA — TESLA MODEL S, MODEL X, MODEL 3, MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V743000·2023-11-03

    Tesla Model S and Model X Incorrect Air Bag Recall

    Tesla is recalling 2021-2024 Model S and Model X vehicles because an incorrect air bag was installed when the steering wheel was replaced. The incompatible air bag could deploy incorrectly during a crash, increasing the risk of injury.

    Product
    TESLA — TESLA MODEL S, MODEL X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V679000·2023-10-11

    2021-2023 Tesla Model X recalled for brake fluid warning system failure

    Tesla is recalling 54,676 Model X vehicles from 2021-2023 because the vehicle controller may fail to detect low brake fluid and not display a warning light, creating a crash risk. Tesla has released a free over-the-air software update to fix the issue.

    Product
    TESLA — TESLA MODEL X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V489000·2023-07-14

    Tesla Recalls 2023 Model S, X, and Y for Camera Misalignment

    Tesla is recalling 2023 Model S, X, and Y vehicles because a misaligned forward-facing camera may disable active safety features without warning, increasing crash risk.

    Product
    TESLA — TESLA MODEL Y, MODEL S, MODEL X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V488000·2023-07-14

    Tesla Model S and Model X seat belts may detach in crash

    Tesla is recalling certain 2021-2023 Model S and Model X vehicles because front-row seat belts may not be connected properly to pretensioner anchors and could detach. A detached seat belt may fail to properly restrain an occupant during a crash.

    Product
    TESLA — TESLA MODEL X, MODEL S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V434000·2023-06-19

    2023 Tesla Model 3 and Model Y Battery Disconnect Defect Recall

    Tesla is recalling 26 Model 3 and Model Y vehicles from 2023 because the pyrotechnic battery disconnect may fail to isolate the high-voltage battery after a crash, creating a risk of electrical shock.

    Product
    TESLA — TESLA MODEL Y, MODEL 3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V422000·2023-06-13

    Tesla Recalls 2023 Semi Trucks for Door Warning System Defect

    Tesla is recalling 2023 Semi trucks because the door warning system allows drivers to dismiss alerts about unlatched doors, increasing injury risk.

    Product
    TESLA — TESLA SEMI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V235000·2023-03-31

    Tesla Recalls 2018-2019 Model 3 Vehicles for Suspension Fastener Issue

    Tesla is recalling 2018-2019 Model 3 vehicles because front suspension fasteners may loosen, potentially causing the lateral link to separate and increasing crash risk.

    Product
    TESLA — TESLA MODEL 3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V130000·2023-02-27

    Tesla Recalls 2022-2023 Model Y Vehicles for Loose Seat Bolts

    Tesla is recalling 2022-2023 Model Y vehicles because second-row seat back frame bolts may not be securely tightened, potentially reducing seat belt performance.

    Product
    TESLA — TESLA MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V085000·2023-02-15

    Tesla Model S Full Self-Driving Beta Software Recall for Unsafe Driving

    Tesla's Full Self-Driving Beta software in 2020 Model S and other models may cause vehicles to drive unsafely through intersections or ignore speed limits. Tesla will provide a free over-the-air software fix.

    Product
    TESLA — TESLA MODEL X, MODEL S, MODEL 3, MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V895000·2022-12-05

    Tesla Recalls 2023 Model Y Vehicles for Suspension Fastener Defect

    Tesla is recalling 2023 Model Y vehicles because front suspension fasteners may not be properly attached, which could cause instability and increase crash risk.

    Product
    TESLA — TESLA MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V844000·2022-11-15

    Tesla Model Y and Model 3 vehicles recalled for taillight failures

    Tesla is recalling certain 2023 Model 3 and 2020-2023 Model Y vehicles because taillights may intermittently fail to illuminate. A failed taillight reduces vehicle visibility and increases crash risk; Tesla is providing a free over-the-air software update.

    Product
    TESLA — TESLA MODEL 3, MODEL Y
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V843000·2022-11-15

    2021-2023 Tesla Model X Passenger Airbag Deployment Defect

    Tesla is recalling certain 2021-2023 Model X vehicles because a software calibration error in the restraint control module may prevent the front passenger airbag from deploying correctly during crashes, increasing injury risk.

    Product
    TESLA — TESLA MODEL X
    Category
    Vehicle
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Tesla

American automotive, energy storage and solar power company

Country
United States
Founded
2003

Official website

Source: Wikidata (Q478214), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.