The Recall Desk

Manufacturer

Heartland Recreational Vehicles, LLC

73 recalls in our database name Heartland Recreational Vehicles, LLC as the manufacturing or recalling firm.

What the numbers show

Total
73
Critical
0
Severe
26
Most recent
2025-05-09

Of the 73 recalls from Heartland Recreational Vehicles, LLC we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 26 (36%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–25 of 73

  • HighNHTSA·25V304000·2025-05-09

    Heartland Cyclone removable step brackets may loosen and detach

    Heartland is recalling certain 2024-2025 Cyclone fifth wheels with a removable step assembly because the clip-on bracket mounting bolts may come loose, allowing the steps to detach.

    Product
    HEARTLAND — HEARTLAND CYCLONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·24V315000·2024-05-03

    Heartland Recalls 2024 Eddie Bauer Travel Trailers for Incorrect Tire Placards

    Heartland is recalling 2024 Eddie Bauer travel trailers because tire placards list the wrong tire size. This labeling error could lead to incorrect tire installation and increased crash risk.

    Product
    HEARTLAND — HEARTLAND EDDIE BAUER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V236000·2024-03-27

    Heartland RV Cooktop LED Backlight Circuit Fire Risk Recall

    Heartland is recalling 10,038 model year 2023-2024 fifth wheels and travel trailers because the LED backlight circuit board in the cooktop range may fail and overheat, increasing the risk of a fire.

    Product
    HEARTLAND — HEARTLAND PROWLER, SOUTH FORK, SUNDANCE, MALLARD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V018000·2024-01-17

    Heartland Recalls 2024 Corterra Fifth Wheels for Incorrect Tire Labels

    Heartland is recalling 2024 Corterra fifth wheels because certification labels may have missing or incorrect tire size information, potentially leading to the installation of wrong tires.

    Product
    HEARTLAND — HEARTLAND CORTERRA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·23V278000·2023-04-19

    2023 Heartland RV Recall: Incorrect Tire Information on Certification Labels

    Heartland Recreational Vehicles is recalling 2023 BIGHORN and BIG COUNTRY fifth wheels with incorrect tire information on federal certification labels, which could allow improper tire installation and increase crash risk.

    Product
    HEARTLAND — HEARTLAND BIG COUNTRY, BIGHORN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V591000·2022-08-08

    Heartland travel trailers recalled for retractable awning defect

    Heartland is recalling certain 2022-2023 travel trailers with defective electric retractable awnings. The welded seam on the awning fabric may separate, causing the awning to drop beyond normal operation.

    Product
    HEARTLAND — HEARTLAND ELKRIDGE, LITHIUM, ROAD WARRIOR, MILESTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V432000·2022-06-17

    2022 Heartland Travel Trailers recalled for cracked LP gas fittings

    Heartland is recalling 2022 travel trailers because quick disconnect fittings in the LP gas system may crack, causing a gas leak that could lead to a fire. Dealers will replace the fittings free of charge.

    Product
    HEARTLAND — HEARTLAND ELKRIDGE, BIG COUNTRY, PIONEER, TORQUE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V305000·2022-05-06

    2022 Heartland Sundance trailers recalled for uninstalled breaker cover

    Heartland is recalling certain 2022 Sundance trailers because the 12-volt breaker cover for the slide-out was not installed during production, exposing studs that may cause electrical arcing and fire.

    Product
    HEARTLAND — HEARTLAND SUNDANCE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V170000·2022-03-21

    2022 Heartland Travel Trailers Recalled for Electrical Fire Risk

    Heartland is recalling certain 2022 Trail Runner, Prowler, and Lithium travel trailers with defective power inlet bolts that may loosen, creating an electrical fire hazard. Dealers will inspect and replace the inlet free of charge.

    Product
    HEARTLAND — HEARTLAND PROWLER, LITHIUM, TRAIL RUNNER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V018000·2022-01-20

    2021-2022 Heartland RVs Recalled for Tire Belt Separation Risk

    Certain 2021-2022 Heartland Cyclone, Fuel, Gravity, and Road Warrior vehicles with Sailun tires may experience belt separation, risking loss of vehicle control. Dealers will replace affected tires at no cost.

    Product
    HEARTLAND — HEARTLAND CYCLONE, GRAVITY, FUEL, ROAD WARRIOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·21V849000·2021-11-01

    Heartland Cyclone and Road Warrior RVs recalled for loose electrical wires

    Heartland Recreational Vehicles is recalling 2019-2021 Road Warrior and 2020-2021 Cyclone trailers because wire securement lugs may be improperly tightened. Loose wires can cause electrical arcing and increase fire risk.

    Product
    HEARTLAND — HEARTLAND CYCLONE, ROAD WARRIOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V453000·2021-06-17

    2021 Heartland Mallard trailers recalled for potentially leaky LP gas cooktop lines

    Heartland Recreational Vehicles is recalling certain 2021 Mallard and other trailers because LP gas lines on outside cooktops may not have been tightened properly, creating a risk of gas leaks and fire.

    Product
    HEARTLAND — HEARTLAND TRAIL RUNNER, WILDERNESS, NORTH TRAIL, MALLARD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V428000·2021-06-04

    Recreational vehicles recalled for propane regulator failure and fire risk

    Heartland and Cruiser recreational vehicles with defective Winntec propane regulators may experience increased pressure, enlarging gas-appliance flames and increasing fire risk. Dealers will replace the regulator free of charge.

    Product
    HEARTLAND — HEARTLAND, CRUISER RV, CRUISER TRAIL RUNNER, LITHIUM, PROWLER, PIONEER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·21V009000·2021-01-14

    2021 Heartland Mallard recreational trailers recalled for suspension defect

    Heartland is recalling certain 2021 Mallard M180BH recreational trailers with incorrect axle, rims, and tires that can cause overloading and increase crash risk. Free replacement parts are available.

    Product
    HEARTLAND — HEARTLAND MALLARD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V521000·2020-08-28

    Heartland Bighorn Traveler landing legs may collapse causing trailer to drop

    Certain 2019-2021 Heartland Cyclone, 2020-2021 Bighorn Traveler, and 2020-2021 Elkridge recreational trailers may have insufficient bracing on the front landing legs, which could buckle and collapse while parked, causing the trailer to drop unexpectedly.

    Product
    HEARTLAND — HEARTLAND CYCLONE, ELKRIDGE, BIGHORN TRAVELER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V275000·2020-05-14

    Heartland Recalls 2020 Trailers Due to Spare Tire Carrier Defect

    Heartland is recalling 2020 Trail Runner, Wilderness, Mallard, and Prowler trailers because a U-bolt on the spare tire carrier may break, causing the tire to detach.

    Product
    HEARTLAND — HEARTLAND WILDERNESS, TRAIL RUNNER, MALLARD, PROWLER
    Category
    Vehicle
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Heartland Recreational Vehicles, LLC

American manufacturer of recreational vehicles

Founded
2003

Official website

Source: Wikidata (Q5692884), licensed CC0. Wikidata is community-edited and may not reflect the current corporate structure.