The Recall Desk

Hazard

Crash Risk recalls

5,751 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
5,751
Critical
0
Severe
2,792
Most recent
2026-09-17

Of the 5,751 crash risk recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,792 (49%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all crash risk recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

4476–4500 of 5751

  • SevereNHTSA·15E061000·2015-07-17

    SAF-Holland Recalls CBX Series Trailer Suspension Systems for Pivot Bolt Failure

    SAF-Holland is recalling CBX series trailer suspension systems because pivot bolts may fail, potentially causing the axle to separate from the trailer and increasing crash risk.

    Product
    SUSPENSION:REAR:AXLE:NON-POWERED AXLE ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15T014000·2015-07-17

    Continental ContiProContact Tires Recalled for Bead Air Leak Defect

    Continental is recalling specific ContiProContact tires manufactured in early 2015 because a manufacturing error may cause air leaks from the bead area, increasing the risk of sudden tire failure and a crash.

    Product
    TIRES:BEAD recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V448000·2015-07-15

    Spartan Emergency Response Vehicles Recalled for Valve Stem Wear

    Spartan is recalling 2007-2015 emergency response vehicles because front wheel valve stems may rub against brake calipers, causing sudden tire deflation.

    Product
    SPARTAN — SPARTAN GLADIATOR, METROSTAR, ADVANTAGE, DIAMOND
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V442000·2015-07-10

    GM Recalls 2014-2015 Chevrolet Cruze and Volt for Steering Defect

    General Motors is recalling specific 2014-2015 Chevrolet Cruze and 2015 Chevrolet Volt vehicles because the inner tie rod may not be tightened correctly, which could cause the tie rod to separate from the steering gear.

    Product
    CHEVROLET — CHEVROLET CRUZE, VOLT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V440000·2015-07-10

    Wilson Recalls 2006-2015 Grain Trailers Due to Kingpin Weld Failure Risk

    Wilson Trailer Company is recalling 2006-2015 Grain trailers because welds on the kingpin assembly may fail, potentially causing the trailer to detach from the tractor.

    Product
    WILSON — WILSON GRAIN TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V435000·2015-07-08

    Ditch Witch T14MV Trailer Recall for Brake Wiring Defect

    Charles Machine Works is recalling 2014-2015 Ditch Witch T14MV trailers due to a wiring defect that may prevent brakes from applying during a breakaway.

    Product
    DITCH WITCH — DITCH WITCH T14MV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V437000·2015-07-08

    Kidron Refrigerated Trailers Recalled for Wiring Harness Defect Affecting ABS

    VT Hackney is recalling 2014-2015 Kidron Refrigerated Trailers because a wiring harness may not supply adequate power to the rear connector, potentially disabling the anti-lock brake system on a second trailer in doubles operation.

    Product
    KIDRON — KIDRON REFRIGERATED TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V439000·2015-07-08

    Honda Recalls Multiple Motorcycles Due to Starter Relay Sealant Defect

    Honda is recalling specific 2013-2016 motorcycles because incorrect sealant on the starter relay may cause electrical power loss and engine stalling.

    Product
    HONDA — HONDA VT750, CB500, CB300F, NC700X
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V436000·2015-07-08

    Ford Recalls 2015 Focus, C-Max, and Escape for Engine Shutdown Defect

    Ford is recalling 2015 Focus, C-Max, and Escape vehicles because the engine may continue running after being turned off, increasing the risk of an unintentional crash.

    Product
    FORD — FORD FOCUS, C-MAX, ESCAPE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V429000·2015-07-06

    Entegra Recalls 2015-2016 Cornerstone Motorhomes Due to Brake Hose Rubbing

    Entegra is recalling 2015-2016 Cornerstone motorhomes because rear jack plates may rub against the brake air hose, potentially reducing braking performance and increasing crash risk.

    Product
    ENTEGRA — ENTEGRA CORNERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V427000·2015-07-06

    Harley-Davidson Recalls 2014-2015 Motorcycles Due to Saddlebag Mounting Defect

    Harley-Davidson is recalling approximately 185,272 model year 2014-2015 motorcycles because saddlebag mounting receptacles may not adequately secure the saddlebags, creating a road hazard.

    Product
    HARLEY-DAVIDSON — HARLEY-DAVIDSON FLHXSE, FLHP, FLHR, FLHTCU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V423000·2015-07-02

    Terex Advance Recalls 2015 Concrete Mixer Trucks Due to Drum Bolt Issue

    Terex Advance is recalling 120 model year 2015 Front Discharge Concrete Mixer Trucks because improperly tightened bolts may allow the mixing drum to separate, increasing crash risk.

    Product
    TEREX ADVANCE — TEREX ADVANCE FRONT DISCHARGE CONCRETE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15E057000·2015-07-02

    Norco Accu Slide Room Mechanism Recall for Unintentional Extension

    Norco is recalling Accu Slide room mechanisms where screws may fail, allowing the room to extend while driving and increasing crash risk.

    Product
    EQUIPMENT:RECREATIONAL VEHICLE/TRAILER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15E055000·2015-07-02

    Osram Sealed Beam Headlamps Recalled for Insufficient Illumination

    Osram is recalling specific Sealed Beam Headlamps that may not meet federal intensity requirements, potentially causing crashes due to poor visibility.

    Product
    EXTERIOR LIGHTING:HEADLIGHTS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V418000·2015-07-01

    Nissan Recalls Juke, Cube, Versa for Sticking Start/Stop Button

    Nissan is recalling 2013-2014 Juke, Cube, and 2014 Versa vehicles because the engine start/stop button may stick, potentially causing the engine to shut off while driving.

    Product
    NISSAN — NISSAN JUKE, CUBE, VERSA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V412000·2015-06-30

    Oshkosh Recalls 2015 S-Series Trucks Due to Torque Converter Paint Issue

    Oshkosh is recalling 24 model year 2015 S-Series concrete mixer glider trucks because paint on the torque converter may soften, causing bolts to loosen and potentially leading to a loss of drive power.

    Product
    OSHKOSH — OSHKOSH S-SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V410000·2015-06-29

    Yamaha Recalls WR250X and WR250R Motorcycles Due to Stator Coil Defect

    Yamaha is recalling 2008-2015 WR250X and WR250R motorcycles because a stator coil defect may cause the battery to die and the engine to stall, increasing crash risk.

    Product
    YAMAHA — YAMAHA WR250X, WR250R
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V405000·2015-06-24

    Shred-Tech MDS Vehicles Recalled for Front Axle Weight Rating Defect

    Shred-Tech is recalling specific MDS models because EPA emission controls cause the front axle to exceed its certified weight rating, increasing crash risk.

    Product
    SHRED-TECH — SHRED-TECH MDS-20GT, MDS-26GTX, MDS 2/26, MDS 1/26
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V400000·2015-06-23

    Starcraft RV Recalls 2014-2016 Trailers for Incorrect Tire Certification Labels

    Starcraft RV is recalling 50 model year 2014-2016 AR-ONE and Comet trailers because certification labels list the wrong tire size, which could lead to improper tire installation and increased crash risk.

    Product
    STARCRAFT RV TT — STARCRAFT RV TT, STARCRAFT COMET, AR-ONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V390000·2015-06-19

    Forest River Recalls Trailers Due to Wheel Stud Breakage Risk

    Forest River is recalling specific model years of Auto Plus, Sandpiper, Vengeance, Cargo Mate, Hydra-Lift, and XLR trailers because wheel studs may break, potentially causing the wheel to detach.

    Product
    FOREST RIVER — FOREST RIVER VENGEANCE, CARGO MATE, HYDRA-LIFT, XLR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V386000·2015-06-17

    Land Rover Recalls LR4 Vehicles Due to Sunroof Adhesive Defect

    Jaguar Land Rover is recalling 2012-2013 LR4 vehicles because the panoramic roof adhesive may not secure the assembly, increasing crash risk.

    Product
    LAND ROVER — LAND ROVER LR4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V384000·2015-06-17

    Trans Tech Student Safety Transport Recalled for Rear Axle Overload Risk

    Transportation Collaborative, Inc. is recalling 2012-2015 Trans Tech Student Safety Transport buses because the rear axle may fail if loaded to full capacity.

    Product
    TRANS TECH — TRANS TECH STUDENT SAFETY TRANSPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide